Chen Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chen Li has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Lei Lei
School of Fire Protection Engineering, China People’s Police University, Langfang 065000, China
2 shared publications - Da Li
Chaoyang Buddhist Culture Museum, Chaoyang 122000, China
1 shared publication - Honghui Liu
School of Fire Protection Engineering, China People’s Police University, Langfang 065000, China
1 shared publication - Kaiyin Gao
School of Fire Protection Engineering, China People’s Police University, Langfang 065000, China
1 shared publication - Minghan Wang
School of Fire Protection Engineering, China People’s Police University, Langfang 065000, China
1 shared publication - Siyuan Zeng
School of Fire Protection Engineering, China People’s Police University, Langfang 065000, China
1 shared publication
Latest Publications
- Open Access
Research on Enhancing Fire Detection Performance in Ancient Architecture Under Occlusion Scenarios Based on YOLO-AR
Fire detection in ancient architecture presents significant challenges due to complex scenes and unique structural characteristics. Traditional detection methods often demonstrate limitations when addressing the specific structural idiosyncrasies of individual ancient buildings and the overlapping occlusion prevalent in architectural complexes. This paper proposes YOLO-AR, a novel fire detection algorithm based on an improved YOLOv8 framework. By embedding the Convolutional Block Attention Module (CBAM) at the end of the backbone network, the algorithm enhances its capability to capture key features of flames and smoke. Furthermore, the Repulsion Loss function is introduced to explicitly optimize bounding box localization accuracy in occluded and dense scenarios. Experiments conducted on a self-constructed ancient architecture dataset comprising 15,847 images demonstrate that YOLO-AR outperforms mainstream comparative algorithms in terms of Precision, Recall, and mean Average Precision (mAP). Specifically, the detection precision reached 90.7%, and the recall rate improved to 89.7%. This study provides an efficient and reliable visual detection solution for early warning systems in ancient architecture, offering significant value for cultural heritage preservation.
Open AccessResearch on Enhancing Fire Detection Performance in Ancient Architecture Under Occlusion Scenarios Based on YOLO-AR
Fire detection in ancient architecture presents significant challenges due to complex scenes and unique structural characteristics. Traditional detection methods often demonstrate limitations when addressing the specific structural idiosyncrasies of individual ancient buildings and the overlapping occlusion prevalent in architectural complexes. This paper proposes YOLO-AR, a novel fire detection algorithm based on an improved YOLOv8 framework. By embedding the Convolutional Block Attention Module (CBAM) at the end of the backbone network, the algorithm enhances its capability to capture key features of flames and smoke. Furthermore, the Repulsion Loss function is introduced to explicitly optimize bounding box localization accuracy in occluded and dense scenarios. Experiments conducted on a self-constructed ancient architecture dataset comprising 15,847 images demonstrate that YOLO-AR outperforms mainstream comparative algorithms in terms of Precision, Recall, and mean Average Precision (mAP). Specifically, the detection precision reached 90.7%, and the recall rate improved to 89.7%. This study provides an efficient and reliable visual detection solution for early warning systems in ancient architecture, offering significant value for cultural heritage preservation.
- Open Access
Research on the Response Regularity of Smoke Fire Detectors Under Typical Interference Conditions in Ancient Buildings
Point-type smoke fire detectors have become one of the most commonly used technical means in the fire detection systems of ancient buildings. However, in practical applications, their performance is easily affected by special environmental interference factors. Therefore, in this study, a full-scale experimental scene of an ancient building with a typical flush gable roof structure was taken as the research object, and the differential influence laws of three typical interference sources, namely wind speed, water vapor, and incense burning, on the response times of point-type smoke detectors were quantified. Moreover, the prediction models of the alarm time of the detectors under the three interference conditions were established. The results indicate the following: (1) Within the range of experimental conditions, there is a quantitative relationship between the detector response delay and the type of interference source: the delay time shows a nonlinear positive correlation with the wind speed/water vapor interference gradient, while it exhibits a threshold unimodal change characteristic with the burning incense interference gradient; (2) under interference conditions, the detector response delay varies depending on the type of fire source: the detector has the best detection stability for smoldering smoke from a smoke cake, while it has the lowest detection sensitivity for smoldering smoke from a cotton rope. Moreover, the influence of wind speed interference is weaker than that of water vapor or smoke from burning incense, and the difference is the greatest in the wood block smoldering condition. (3) Construct a detector alarm time prediction model under three types of interference conditions, where the wind speed, water vapor, and burning incense interference conditions conform to third-order polynomial functions, Sigmoid functions, and fourth-order polynomial functions, respectively.
Open AccessResearch on the Response Regularity of Smoke Fire Detectors Under Typical Interference Conditions in Ancient Buildings
Point-type smoke fire detectors have become one of the most commonly used technical means in the fire detection systems of ancient buildings. However, in practical applications, their performance is easily affected by special environmental interference factors. Therefore, in this study, a full-scale experimental scene of an ancient building with a typical flush gable roof structure was taken as the research object, and the differential influence laws of three typical interference sources, namely wind speed, water vapor, and incense burning, on the response times of point-type smoke detectors were quantified. Moreover, the prediction models of the alarm time of the detectors under the three interference conditions were established. The results indicate the following: (1) Within the range of experimental conditions, there is a quantitative relationship between the detector response delay and the type of interference source: the delay time shows a nonlinear positive correlation with the wind speed/water vapor interference gradient, while it exhibits a threshold unimodal change characteristic with the burning incense interference gradient; (2) under interference conditions, the detector response delay varies depending on the type of fire source: the detector has the best detection stability for smoldering smoke from a smoke cake, while it has the lowest detection sensitivity for smoldering smoke from a cotton rope. Moreover, the influence of wind speed interference is weaker than that of water vapor or smoke from burning incense, and the difference is the greatest in the wood block smoldering condition. (3) Construct a detector alarm time prediction model under three types of interference conditions, where the wind speed, water vapor, and burning incense interference conditions conform to third-order polynomial functions, Sigmoid functions, and fourth-order polynomial functions, respectively.