Jinke Mao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jinke Mao has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Jianyong Hu
Institute of Water Sciences, Zhejiang University of Water Resources and Electric Power, Hangzhou 310018, China
4 shared publications - Haijing Gao
Bureau of Forestry and Water Resources of Fuyang District, Hangzhou 311400, China
2 shared publications - Jingyuan Cui
Institute of Water Sciences, Zhejiang University of Water Resources and Electric Power, Hangzhou 310018, China
2 shared publications - Wenjing Hu
School of Marine Engineering Equipment, Zhejiang Ocean University, Zhoushan 316022, China
2 shared publications - Dajiang He
Bureau of Forestry and Water Resources of Fuyang District, Hangzhou 311400, China
1 shared publication - Delei Yu
Institute of Water Sciences, Zhejiang University of Water Resources and Electric Power, Hangzhou 310018, China
1 shared publication
Latest Publications
- Open Access
Optimizing Water Hammer Protection Strategies for Water Conveyance Systems at Floating Pump Stations Experiencing Large Water Level Fluctuations
Under large water level fluctuations, emergency pump shutdown in floating pump stations tends to induce severe water hammer oscillations, with consequences including excessive negative pressure, potential cavitation and water-column-separation risk, and uncontrolled pump reverse rotation; this seriously threatens the operational safety of water intake systems. We seek to develop an economical and effective water hammer protection strategy. Therefore, we study a long-distance water conveyance project with a floating pump station, establish a numerical model of hydraulic transient processes, and carry out a numerical simulation of a pump-trip water hammer, enacting a combined protection strategy that integrates rules on pump outlet valve closure and air vessels. Meanwhile, we analyze the regulation effects of key parameters, including air vessel volume, connecting pipe diameter, and water–air ratio (the ratio of initial water volume to initial air volume inside the air vessel), on the pipeline pressure and pump rotational speed. Overall, with the simultaneous shutdown of three pumps at the minimum operating water level, negative pressure seriously exceeds its limits in the absence of protective measures. In optimizing the valve closure rule alone, we can effectively suppress reverse pump rotation, but this fails to effectively address the issue of negative pipeline pressure. After introducing air vessels to form a combined protection system, the indicative negative-pressure severity in the pipeline significantly improves due to the synergistic effect of valve closure (suppressing reverse rotation) and air vessels (regulating the pressure). On this basis, we identify the best-performing option among the investigated cases, on the premise that a larger volume is economically unjustified, via multi-parameter comparative analysis. This consists of a two-stage valve closure rule (a 5 s fast closure duration + 80% fast closure angle + 35 s slow closure duration) alongside an air vessel with a 15 m3 volume, a 0.3 m connecting pipe diameter, and a 1:1 water–air ratio, and a terminal air valve with a 300 mm air intake diameter. This scheme balances hydraulic safety and engineering economy; the maximum pipeline pressure, minimum pipeline pressure, and maximum pump reverse speed all meet specification requirements, enabling risk control for the investigated pump-trip water-hammer conditions. These research findings provide a theoretical basis and technical support for the design of water hammer protection schemes in similar water conveyance projects at floating pump stations.
Open AccessOptimizing Water Hammer Protection Strategies for Water Conveyance Systems at Floating Pump Stations Experiencing Large Water Level Fluctuations
Under large water level fluctuations, emergency pump shutdown in floating pump stations tends to induce severe water hammer oscillations, with consequences including excessive negative pressure, potential cavitation and water-column-separation risk, and uncontrolled pump reverse rotation; this seriously threatens the operational safety of water intake systems. We seek to develop an economical and effective water hammer protection strategy. Therefore, we study a long-distance water conveyance project with a floating pump station, establish a numerical model of hydraulic transient processes, and carry out a numerical simulation of a pump-trip water hammer, enacting a combined protection strategy that integrates rules on pump outlet valve closure and air vessels. Meanwhile, we analyze the regulation effects of key parameters, including air vessel volume, connecting pipe diameter, and water–air ratio (the ratio of initial water volume to initial air volume inside the air vessel), on the pipeline pressure and pump rotational speed. Overall, with the simultaneous shutdown of three pumps at the minimum operating water level, negative pressure seriously exceeds its limits in the absence of protective measures. In optimizing the valve closure rule alone, we can effectively suppress reverse pump rotation, but this fails to effectively address the issue of negative pipeline pressure. After introducing air vessels to form a combined protection system, the indicative negative-pressure severity in the pipeline significantly improves due to the synergistic effect of valve closure (suppressing reverse rotation) and air vessels (regulating the pressure). On this basis, we identify the best-performing option among the investigated cases, on the premise that a larger volume is economically unjustified, via multi-parameter comparative analysis. This consists of a two-stage valve closure rule (a 5 s fast closure duration + 80% fast closure angle + 35 s slow closure duration) alongside an air vessel with a 15 m3 volume, a 0.3 m connecting pipe diameter, and a 1:1 water–air ratio, and a terminal air valve with a 300 mm air intake diameter. This scheme balances hydraulic safety and engineering economy; the maximum pipeline pressure, minimum pipeline pressure, and maximum pump reverse speed all meet specification requirements, enabling risk control for the investigated pump-trip water-hammer conditions. These research findings provide a theoretical basis and technical support for the design of water hammer protection schemes in similar water conveyance projects at floating pump stations.
- Open Access
Study on Hydraulic Safety Control Strategies for Gravity Flow Water Supply Project with Long-Distance and Multi-Fluctuation Pressure Tunnels
During the sudden closure of gates in long-distance gravity flow water supply projects, intense water hammer waves are generated. These waves can cause severe damage to the water supply tunnel structure, posing a significant threat to project safety. To develop an economical and effective hydraulic safety control strategy, this study uses the example of a specific gravity flow water supply project with long-distance and multi-fluctuation pressure tunnels in Zhejiang Province. A novel combined protection strategy was investigated, involving the conversion of construction branch tunnels into branch tunnel surge tanks combined with an overflow surge tank. Numerical simulations of gate closure-induced water hammer pressures were conducted using the method of characteristics. Additionally, the effectiveness of the overflow surge tank on controlling the surge water level in the branch tunnels was analyzed with respect to variations in its height, diameter, and impedance hole diameter. The results indicate that a 300 s linear gate closure without any protective measures induces severe water hammer pressure. Extending the closure time to 1200 s still results in pressures far exceeding the safety threshold. Converting construction branch tunnels into surge tanks effectively controlled the water hammer pressure; however, overflow issues emerged in some branch tunnels. The subsequent addition of an overflow surge tank at the end of the water supply system successfully eliminated the risk of overflow in the branch tunnels. Building upon this, multi-parameter optimization analysis was used to determine the optimal configuration for the overflow surge tank. This solution ensures hydraulic safety while maintaining cost-effectiveness. Both the maximum pressure and the minimum pressure along the water supply tunnel, as well as the surge water levels in all branch tunnels, meet the code requirements. Furthermore, the reduced size of the surge tank significantly lowered construction costs. The findings of this research provide theoretical foundations and technical support for similar long-distance gravity flow water supply projects.
Open AccessStudy on Hydraulic Safety Control Strategies for Gravity Flow Water Supply Project with Long-Distance and Multi-Fluctuation Pressure Tunnels
During the sudden closure of gates in long-distance gravity flow water supply projects, intense water hammer waves are generated. These waves can cause severe damage to the water supply tunnel structure, posing a significant threat to project safety. To develop an economical and effective hydraulic safety control strategy, this study uses the example of a specific gravity flow water supply project with long-distance and multi-fluctuation pressure tunnels in Zhejiang Province. A novel combined protection strategy was investigated, involving the conversion of construction branch tunnels into branch tunnel surge tanks combined with an overflow surge tank. Numerical simulations of gate closure-induced water hammer pressures were conducted using the method of characteristics. Additionally, the effectiveness of the overflow surge tank on controlling the surge water level in the branch tunnels was analyzed with respect to variations in its height, diameter, and impedance hole diameter. The results indicate that a 300 s linear gate closure without any protective measures induces severe water hammer pressure. Extending the closure time to 1200 s still results in pressures far exceeding the safety threshold. Converting construction branch tunnels into surge tanks effectively controlled the water hammer pressure; however, overflow issues emerged in some branch tunnels. The subsequent addition of an overflow surge tank at the end of the water supply system successfully eliminated the risk of overflow in the branch tunnels. Building upon this, multi-parameter optimization analysis was used to determine the optimal configuration for the overflow surge tank. This solution ensures hydraulic safety while maintaining cost-effectiveness. Both the maximum pressure and the minimum pressure along the water supply tunnel, as well as the surge water levels in all branch tunnels, meet the code requirements. Furthermore, the reduced size of the surge tank significantly lowered construction costs. The findings of this research provide theoretical foundations and technical support for similar long-distance gravity flow water supply projects.
- Open Access
Analysis of Vibration Characteristics of Viscoelastic Slurry Pipe Considering Fluid–Structure Interaction Effects
To study the vibration characteristics of viscoelastic slurry pipe structures under fluid–structure interaction (FSI), we constructed a three-dimensional FSI pipe model based on the finite element method to systematically investigate the effects of fluid effects, pipe length, and wall thickness on the vibrational characteristics of viscoelastic slurry pipes. A modal analysis demonstrated that fluid effects not only significantly reduced the natural frequency of the pipe but also disrupted the symmetry of the vibration modes and eliminated the phenomenon of frequency degeneracy. The frequency reduction caused by FSI reached 54%, which was dominant compared with the water-attached effects, and its impact intensified with the increasing vibration order. The water-attached effect exhibited differences between odd and even orders, attributed to the influence of vibration modes on the distribution of fluid inertial forces, with a contribution of 45.07% to 55.24% in the odd orders and of only 37.69% to 38.93% in the even orders. When the FSI and water-attached effects acted together, the frequency reduction was further aggravated, but the reduction ratio did not follow a simple linear superposition. The parametric analysis of the pipe showed that when the pipe length increased from 1 m to 3 m, the growth rate of its natural frequency was only 26.52% that of the shorter pipe, indicating that the longer the pipes, the slower the growth rate of frequency. When the wall thickness increased from 5 mm to 11 mm, the growth rate of the first-order natural frequency decreased from 15.43% to 7.44%, suggesting that the frequency improvement effect caused by the stiffness augmentation diminished with the increase in wall thickness. The research results hold significant guiding significance for the structural design of slurry pipe systems in practical engineering and the safe operation of pipe systems.
Open AccessAnalysis of Vibration Characteristics of Viscoelastic Slurry Pipe Considering Fluid–Structure Interaction Effects
To study the vibration characteristics of viscoelastic slurry pipe structures under fluid–structure interaction (FSI), we constructed a three-dimensional FSI pipe model based on the finite element method to systematically investigate the effects of fluid effects, pipe length, and wall thickness on the vibrational characteristics of viscoelastic slurry pipes. A modal analysis demonstrated that fluid effects not only significantly reduced the natural frequency of the pipe but also disrupted the symmetry of the vibration modes and eliminated the phenomenon of frequency degeneracy. The frequency reduction caused by FSI reached 54%, which was dominant compared with the water-attached effects, and its impact intensified with the increasing vibration order. The water-attached effect exhibited differences between odd and even orders, attributed to the influence of vibration modes on the distribution of fluid inertial forces, with a contribution of 45.07% to 55.24% in the odd orders and of only 37.69% to 38.93% in the even orders. When the FSI and water-attached effects acted together, the frequency reduction was further aggravated, but the reduction ratio did not follow a simple linear superposition. The parametric analysis of the pipe showed that when the pipe length increased from 1 m to 3 m, the growth rate of its natural frequency was only 26.52% that of the shorter pipe, indicating that the longer the pipes, the slower the growth rate of frequency. When the wall thickness increased from 5 mm to 11 mm, the growth rate of the first-order natural frequency decreased from 15.43% to 7.44%, suggesting that the frequency improvement effect caused by the stiffness augmentation diminished with the increase in wall thickness. The research results hold significant guiding significance for the structural design of slurry pipe systems in practical engineering and the safe operation of pipe systems.
- Open Access
Optimizing Cascade Hydropower Operations for Flood Control Using Unmanned Vessel Bathymetry
To enhance regional flood control capacity, this study focused on the DX River section in Zhejiang Province. Unmanned vessel bathymetry was employed to obtain precise river cross-section data. A hydrodynamic model was established to simulate flood propagation processes and conduct flood routing analyses. Flood scenarios under 5-year, 10-year, and 20-year return periods were simulated to assess water level variations and overflow risks. The results indicate that under a 5-year flood, 19.5% of the right bank fails to meet flood control standards. This risk intensifies significantly with increasing return periods. Building on these findings, a flood optimal operation model was developed. The resulting coordinated strategy, which lowers the peak water level by 1.2 m during a 20-year flood, is sufficient to prevent overflow at the critical section and enhances regional flood control capacity. This is followed by dynamic gate regulation to match the outflow to the inflow. Dynamic regulation of spillway gates should then be implemented to achieve outflow rates commensurate with the incoming flood magnitude. This study demonstrates a robust workflow from high-resolution data acquisition to actionable operational rules, providing a transferable framework for mitigating flood risks in complex, regulated river systems.
Open AccessOptimizing Cascade Hydropower Operations for Flood Control Using Unmanned Vessel Bathymetry
To enhance regional flood control capacity, this study focused on the DX River section in Zhejiang Province. Unmanned vessel bathymetry was employed to obtain precise river cross-section data. A hydrodynamic model was established to simulate flood propagation processes and conduct flood routing analyses. Flood scenarios under 5-year, 10-year, and 20-year return periods were simulated to assess water level variations and overflow risks. The results indicate that under a 5-year flood, 19.5% of the right bank fails to meet flood control standards. This risk intensifies significantly with increasing return periods. Building on these findings, a flood optimal operation model was developed. The resulting coordinated strategy, which lowers the peak water level by 1.2 m during a 20-year flood, is sufficient to prevent overflow at the critical section and enhances regional flood control capacity. This is followed by dynamic gate regulation to match the outflow to the inflow. Dynamic regulation of spillway gates should then be implemented to achieve outflow rates commensurate with the incoming flood magnitude. This study demonstrates a robust workflow from high-resolution data acquisition to actionable operational rules, providing a transferable framework for mitigating flood risks in complex, regulated river systems.