Sarin Rungmanee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sarin Rungmanee has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- B. Tucker Woodson
Division of Sleep Medicine and Surgery, Department of Otolaryngology and Communication Sciences Medical College of Wisconsin Milwaukee Wisconsin USA
1 shared publication Chawanon Pimolsri
Siriraj Sleep Center, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
1 shared publication- Jindapa Srikajon
Siriraj Sleep Center, Siriraj Hospital, Mahidol University, Bangkok, Thailand
1 shared publication - Navarat Kasemsuk
Department of Otorhinolaryngology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
1 shared publication - Nithita Sattaratpaijit
Division of Sleep Medicine and Surgery, Department of Otolaryngology and Communication Sciences, Medical College of Wisconsin, Milwaukee, USA
1 shared publication Vipada Tirachaimongkol
Department of Otorhinolaryngology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
1 shared publication
Latest Publications
- Open Access
- 11 March 2026
- Published by Springer Nature in Sleep and Breathing
- Vol. 30 (1) , 87
The effect of tongue strength and endurance in patients with obstructive sleep apnea
Purpose This study aimed to evaluate tongue strength and endurance in patients with OSA and identify variables that modify their effects on OSA severity. Methods A cross-sectional study included 189 adults with OSA, classified according to the apnea-hypopnea index (AHI) as mild (n = 63), moderate (n = 52), or severe (n = 74). The anterior and posterior tongue strengths, and tongue endurance were measured using the IOPI® Pro device. General linear models were applied to estimate unadjusted and adjusted marginal means. Adjustment was made for age, sex, and body mass index (BMI). Results The anterior tongue strength did not differ significantly across mild, moderate, and severe OSA (56.11 ± 11.31 vs. 51.32 ± 10.67 vs. 55.55 ± 13.22 kPa, p = 0.07), nor did posterior tongue strength (50.16 ± 16.14 vs. 46.25 ± 12.55 vs. 47.84 ± 13.39 kPa, p = 0.328), or tongue endurance (16.00 (12,22) vs. 14.75 (12,17.5) vs. 17.30 (13,23) seconds, p = 0.744). BMI was a significant effect modifier for anterior and posterior tongue strength. In the non-obese subgroup (BMI < 30 kg/m2) adjusted analyses for age and gender revealed differences in mean anterior (diff = 10.48, p = 0.017) and posterior (diff = 13.26, p = 0.02) tongue strength between patients with mild and severe OSA. Conclusion In an adult cohort, tongue strength did not differ among patients with mild, moderate, and severe OSA. However, in non-obese patients (BMI < 30 kg/m²), tongue strength was lower in those with severe OSA compared to those with mild OSA. Future studies on the impact of tongue strength may be best directed at non-obese patients with OSA.
- 11 March 2026
- Published by Springer Nature in Sleep and Breathing
- Vol. 30 (1) , 87
Open AccessThe effect of tongue strength and endurance in patients with obstructive sleep apnea
Purpose This study aimed to evaluate tongue strength and endurance in patients with OSA and identify variables that modify their effects on OSA severity. Methods A cross-sectional study included 189 adults with OSA, classified according to the apnea-hypopnea index (AHI) as mild (n = 63), moderate (n = 52), or severe (n = 74). The anterior and posterior tongue strengths, and tongue endurance were measured using the IOPI® Pro device. General linear models were applied to estimate unadjusted and adjusted marginal means. Adjustment was made for age, sex, and body mass index (BMI). Results The anterior tongue strength did not differ significantly across mild, moderate, and severe OSA (56.11 ± 11.31 vs. 51.32 ± 10.67 vs. 55.55 ± 13.22 kPa, p = 0.07), nor did posterior tongue strength (50.16 ± 16.14 vs. 46.25 ± 12.55 vs. 47.84 ± 13.39 kPa, p = 0.328), or tongue endurance (16.00 (12,22) vs. 14.75 (12,17.5) vs. 17.30 (13,23) seconds, p = 0.744). BMI was a significant effect modifier for anterior and posterior tongue strength. In the non-obese subgroup (BMI < 30 kg/m2) adjusted analyses for age and gender revealed differences in mean anterior (diff = 10.48, p = 0.017) and posterior (diff = 13.26, p = 0.02) tongue strength between patients with mild and severe OSA. Conclusion In an adult cohort, tongue strength did not differ among patients with mild, moderate, and severe OSA. However, in non-obese patients (BMI < 30 kg/m²), tongue strength was lower in those with severe OSA compared to those with mild OSA. Future studies on the impact of tongue strength may be best directed at non-obese patients with OSA.
- Open Access
- 7 August 2025
- Published by Springer Nature in Sleep and Breathing
- Vol. 29 (4) , 1-8
Belun Sleep Platform versus in-lab polysomnography for obstructive sleep apnea diagnosis
Objective: We aimed to compare the Belun Sleep Platform (BSP), an artificial intelligence-driven home sleep testing device, with polysomnography (PSG) for diagnosing obstructive sleep apnea. The BSP analyzes oxygen saturation, heart rate, and accelerometry patterns. Methods: Participants scheduled for PSG and with no significant cardiovascular or neuromuscular comorbidities were recruited. They underwent simultaneous in-laboratory, full-night PSG with the BSP. We assessed diagnostic properties, including sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. Results: A total of 40 participants (54.3% male) with a mean age of 49.9 years were enrolled. For an apnea-hypopnea index (AHI) cutoff of ≥ 15 events/h, BSP showed an accuracy of 68.5%, sensitivity of 35.2%, and specificity of 100% under American Academy of Sleep Medicine criteria 1 A and 1B. For AHI thresholds of ≥ 5 and ≥ 30 events/h, sensitivity was 82.1% and 33.3%, respectively, while specificity was 14.2% and 100%, respectively. BSP-AHI correlated moderately with PSG-AHI (intraclass correlation coefficient [ICC] = 0.737). BSP’s oxygen desaturation index (ODI) showed a strong correlation with PSG-ODI (ICC = 0.882). Moderate correlations were observed between BSP and PSG for non-rapid eye movement sleep duration (ICC = 0.736), rapid eye movement sleep duration (ICC = 0.664), total sleep time (ICC = 0.617), and sleep efficiency (ICC = 0.719). Conclusions: The BSP’s high specificity but low sensitivity suggests it serves better as a confirmatory tool rather than a primary screening method. Its moderate concordance with PSG underscores its potential in settings where PSG is unavailable. However, further investigation is needed to refine its clinical applications.
- 7 August 2025
- Published by Springer Nature in Sleep and Breathing
- Vol. 29 (4) , 1-8
Open AccessBelun Sleep Platform versus in-lab polysomnography for obstructive sleep apnea diagnosis
Objective: We aimed to compare the Belun Sleep Platform (BSP), an artificial intelligence-driven home sleep testing device, with polysomnography (PSG) for diagnosing obstructive sleep apnea. The BSP analyzes oxygen saturation, heart rate, and accelerometry patterns. Methods: Participants scheduled for PSG and with no significant cardiovascular or neuromuscular comorbidities were recruited. They underwent simultaneous in-laboratory, full-night PSG with the BSP. We assessed diagnostic properties, including sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. Results: A total of 40 participants (54.3% male) with a mean age of 49.9 years were enrolled. For an apnea-hypopnea index (AHI) cutoff of ≥ 15 events/h, BSP showed an accuracy of 68.5%, sensitivity of 35.2%, and specificity of 100% under American Academy of Sleep Medicine criteria 1 A and 1B. For AHI thresholds of ≥ 5 and ≥ 30 events/h, sensitivity was 82.1% and 33.3%, respectively, while specificity was 14.2% and 100%, respectively. BSP-AHI correlated moderately with PSG-AHI (intraclass correlation coefficient [ICC] = 0.737). BSP’s oxygen desaturation index (ODI) showed a strong correlation with PSG-ODI (ICC = 0.882). Moderate correlations were observed between BSP and PSG for non-rapid eye movement sleep duration (ICC = 0.736), rapid eye movement sleep duration (ICC = 0.664), total sleep time (ICC = 0.617), and sleep efficiency (ICC = 0.719). Conclusions: The BSP’s high specificity but low sensitivity suggests it serves better as a confirmatory tool rather than a primary screening method. Its moderate concordance with PSG underscores its potential in settings where PSG is unavailable. However, further investigation is needed to refine its clinical applications.