Iulian Gherasim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Iulian Gherasim has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Florin-Emilian Țurcanu
Department of Building Services, Faculty of Civil Engineering and Building Services, Gheorghe Asachi Technical University of Iași, Iasi, Romania, Romania
4 shared publications - Sebastian Valeriu Hudișteanu
Department of Building Services, Faculty of Civil Engineering and Building Services, Gheorghe Asachi Technical University of Iași, Iasi, Romania, Romania
4 shared publications - Cătălin-George Popovici
Department of Building Services, Faculty of Civil Engineering and Building Services, Gheorghe Asachi Technical University of Iași, Iasi, Romania, Romania
3 shared publications - Nelu-Cristian Cherecheș
Department of Building Services, Faculty of Civil Engineering and Building Services, Gheorghe Asachi Technical University of Iași, Iasi, Romania, Romania
3 shared publications - Catalin Daniel Galatanu
Faculty of Civil Engineering and Building Services, “Gheorghe Asachi” Technical University, 700050 Iasi, Romania
2 shared publications - Claudiu Romila
Department of Civil and Industrial Engineering, Faculty of Civil Engineering and Building Services, Gheorghe Asachi Technical University of Iași, Iasi, Romania, Romania
2 shared publications
Latest Publications
- Open Access
- 18 November 2026
- Published by MDPI AG in Preprints.org
Spatial, Temporal and Power Consistency in a Reconstructed Electric-Floor Experiment
Surface agreement in a heated floor does not establish the accuracy of internal temperatures. This study reconstructs sixteen operating conditions and twelve pages of measurement bulletins from a 1999 electric-floor experiment. A multilayer Fourier model distinguishes surface averages, cable-adjacent temperatures and inter-cable temperatures; calculations are checked using EES, finite elements and Fluent. Unfitted predictions have mean absolute discrepancies of 0.918 K at the finished surface, 17.379 K beneath a cable and 8.454 K between cables. An observable-specific inversion tests whether heating input alone can reconcile the records. Matching cable-adjacent temperatures requires 1.56–2.70 times nominal power, whereas printed face-flux sums differ from nominal input by at most 1.11%. For a 90 W m-2 condition, the cable-point fit requires 196.4 W m-2 and predicts a surface temperature of 34.26 ◦C against the printed 25.5 ◦C. Thirty upper-insulation records also rise by 1.06–2.33 K over the final labelled three-hour interval. These findings exclude a power-only reconciliation within the specified steady, fixed-property model. The contribution is a reproducible consistency diagnostic linking spatial observations, energy balance and temporal stability; missing contact and time-history information prevents complete experimental validation.
- 18 November 2026
- Published by MDPI AG in Preprints.org
Open AccessSpatial, Temporal and Power Consistency in a Reconstructed Electric-Floor Experiment
Surface agreement in a heated floor does not establish the accuracy of internal temperatures. This study reconstructs sixteen operating conditions and twelve pages of measurement bulletins from a 1999 electric-floor experiment. A multilayer Fourier model distinguishes surface averages, cable-adjacent temperatures and inter-cable temperatures; calculations are checked using EES, finite elements and Fluent. Unfitted predictions have mean absolute discrepancies of 0.918 K at the finished surface, 17.379 K beneath a cable and 8.454 K between cables. An observable-specific inversion tests whether heating input alone can reconcile the records. Matching cable-adjacent temperatures requires 1.56–2.70 times nominal power, whereas printed face-flux sums differ from nominal input by at most 1.11%. For a 90 W m-2 condition, the cable-point fit requires 196.4 W m-2 and predicts a surface temperature of 34.26 ◦C against the printed 25.5 ◦C. Thirty upper-insulation records also rise by 1.06–2.33 K over the final labelled three-hour interval. These findings exclude a power-only reconciliation within the specified steady, fixed-property model. The contribution is a reproducible consistency diagnostic linking spatial observations, energy balance and temporal stability; missing contact and time-history information prevents complete experimental validation.
- Open Access
- 18 November 2026
- Published by MDPI AG in Preprints.org
Three-Dimensional End Effects and Measurement-Region Dependence in Electrically Heated Slabs
Finite electric-heating panels are often assessed using transverse temperature profiles, although cable turns can alter whole-surface nonuniformity. This study reconstructs three Kanthal-heated panels from historical photographs, drawings and electrical resistances. Panel widths of 400, 500 and 600 mm correspond to cable pitches of 100, 150 and 200 mm. Three-dimensional multilayer Fourier solutions retain finite serpentine paths and are checked by independent finite-volume and MATLAB calculations. At 70 W m⁻², with adiabatic sides and a drawing-based length of 1.2 m, whole-surface ranges are 5.694, 5.595 and 5.926 K, compared with transverse-model values of 3.779, 3.560 and 3.512 K. P3 retains an almost unchanged mid-length range despite substantial end effects. Excluding 200 mm at each longitudinal end reverses the panel ranking. Twenty-four additional finite-volume cases test assumed lateral coefficients of 0, 2 and 8.3 W m⁻² K⁻¹, with refinement to 11.06 million control volumes. Whole-top variation exceeds mid-length variation throughout; final refinement changes whole-top ranges by less than 0.024 K. The results establish case-specific dependence on geometry, observation region and boundary losses. Historical experimental summaries remain conditional comparisons because sensor selection and boundary conditions are incompletely specified.
- 18 November 2026
- Published by MDPI AG in Preprints.org
Open AccessThree-Dimensional End Effects and Measurement-Region Dependence in Electrically Heated Slabs
Finite electric-heating panels are often assessed using transverse temperature profiles, although cable turns can alter whole-surface nonuniformity. This study reconstructs three Kanthal-heated panels from historical photographs, drawings and electrical resistances. Panel widths of 400, 500 and 600 mm correspond to cable pitches of 100, 150 and 200 mm. Three-dimensional multilayer Fourier solutions retain finite serpentine paths and are checked by independent finite-volume and MATLAB calculations. At 70 W m⁻², with adiabatic sides and a drawing-based length of 1.2 m, whole-surface ranges are 5.694, 5.595 and 5.926 K, compared with transverse-model values of 3.779, 3.560 and 3.512 K. P3 retains an almost unchanged mid-length range despite substantial end effects. Excluding 200 mm at each longitudinal end reverses the panel ranking. Twenty-four additional finite-volume cases test assumed lateral coefficients of 0, 2 and 8.3 W m⁻² K⁻¹, with refinement to 11.06 million control volumes. Whole-top variation exceeds mid-length variation throughout; final refinement changes whole-top ranges by less than 0.024 K. The results establish case-specific dependence on geometry, observation region and boundary losses. Historical experimental summaries remain conditional comparisons because sensor selection and boundary conditions are incompletely specified.
- Open Access
- 20 September 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (18) , 8455
The Effect of Spectrum-Enhanced Artificial Light on Students’ Cognitive Activities
Light is a powerful environmental factor with proven effects on human cognitive activity. This study investigated the effects of two types of light—LED with an enhanced long-wavelength spectrum and classic fluorescent—on concentration and attention of undergraduate students. Concentration was assessed through EEG, while attention was evaluated using d2 and TP psychometric tests. The experiment was carried out in a classroom equipped with both lighting systems, with each participant completing two testing sessions under different light conditions, separated by at least seven days to allow for washout. Results showed that during the first administration, LED lighting supported better performance across both EEG and psychometric measures compared to fluorescent light, suggesting enhanced concentration and attention. By the second administration, these differences were less evident, likely due to learning and task familiarization effects. Nonparametric ANOVA-type analyses further indicated that the effect of lighting on performance depended not only on the light type but also on the order of exposure, with students who switched from fluorescent to LED showing improvement, whereas the reverse sequence was associated with a decline. Overall, the findings suggest that LED lighting enriched in warm tones may positively influence attention and concentration, though results should be viewed as exploratory due to the small sample size.
- 20 September 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (18) , 8455
Open AccessThe Effect of Spectrum-Enhanced Artificial Light on Students’ Cognitive Activities
Light is a powerful environmental factor with proven effects on human cognitive activity. This study investigated the effects of two types of light—LED with an enhanced long-wavelength spectrum and classic fluorescent—on concentration and attention of undergraduate students. Concentration was assessed through EEG, while attention was evaluated using d2 and TP psychometric tests. The experiment was carried out in a classroom equipped with both lighting systems, with each participant completing two testing sessions under different light conditions, separated by at least seven days to allow for washout. Results showed that during the first administration, LED lighting supported better performance across both EEG and psychometric measures compared to fluorescent light, suggesting enhanced concentration and attention. By the second administration, these differences were less evident, likely due to learning and task familiarization effects. Nonparametric ANOVA-type analyses further indicated that the effect of lighting on performance depended not only on the light type but also on the order of exposure, with students who switched from fluorescent to LED showing improvement, whereas the reverse sequence was associated with a decline. Overall, the findings suggest that LED lighting enriched in warm tones may positively influence attention and concentration, though results should be viewed as exploratory due to the small sample size.
- Open Access
- 8 August 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (16) , 7179
Technical and Economic Analysis of Sustainable Photovoltaic Systems for Street Lighting
This paper presents an analysis of the feasibility and sustainability of using local photovoltaic systems, ON-GRID central photovoltaic systems, and HYBRID systems for street lighting. By generating electricity from renewable sources (photovoltaic panels), solar energy contributes to environmental protection by avoiding the use of fossil fuels and nuclear fission energy, while also aligning with the European Union’s Energy Strategy commitments for the medium term (until 2030) and long term (toward 2050). The implementation of local/central photovoltaic systems for street lighting largely depends on the existing power supply infrastructure, the solar potential of the site, and a clear understanding of potential electricity and cost savings. This study compares local and central photovoltaic systems for street lighting to analyze their technical performance and economic feasibility. The main sustainable objective that this work aims to achieve is Sustainable Development Goal 7. The optimal solution for photovoltaic systems in street lighting was determined through this analysis. The estimated cost for implementing an ON-GRID photovoltaic power plant with a capacity of 153.90 kWp is approximately EUR 773,977.22, with a discounted Payback Time of about 9.33 years. The implementation of this solution results in an annual reduction in greenhouse gas emissions by approximately 58.52 tons of CO2.
- 8 August 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (16) , 7179
Open AccessTechnical and Economic Analysis of Sustainable Photovoltaic Systems for Street Lighting
This paper presents an analysis of the feasibility and sustainability of using local photovoltaic systems, ON-GRID central photovoltaic systems, and HYBRID systems for street lighting. By generating electricity from renewable sources (photovoltaic panels), solar energy contributes to environmental protection by avoiding the use of fossil fuels and nuclear fission energy, while also aligning with the European Union’s Energy Strategy commitments for the medium term (until 2030) and long term (toward 2050). The implementation of local/central photovoltaic systems for street lighting largely depends on the existing power supply infrastructure, the solar potential of the site, and a clear understanding of potential electricity and cost savings. This study compares local and central photovoltaic systems for street lighting to analyze their technical performance and economic feasibility. The main sustainable objective that this work aims to achieve is Sustainable Development Goal 7. The optimal solution for photovoltaic systems in street lighting was determined through this analysis. The estimated cost for implementing an ON-GRID photovoltaic power plant with a capacity of 153.90 kWp is approximately EUR 773,977.22, with a discounted Payback Time of about 9.33 years. The implementation of this solution results in an annual reduction in greenhouse gas emissions by approximately 58.52 tons of CO2.