Deepika Bhalla
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Deepika Bhalla has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Jashandeep Singh
Bhai Gurdas Polytechnic College, Sangrur, Punjab, India
2 shared publications - Kulraj Kaur
IKGPTU, Kapurthala, India
2 shared publications - Avnesh Verma
Department of Instrumentation (formerly USIC), Kurukshetra University, Kurukshetra 136119, India
1 shared publication Genius Walia
Department of Physics, Guru Kashi University, Talwandi Sabo, India
1 shared publication- Vibhuti Rehalia
SSCET
1 shared publication
Latest Publications
- 22 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (4) , 2108-2115
A New Six-Gas-Based Fault Prediction Graphical Technique in Dissolved Gas Analysis for Oil-Immersed Power Transformer
Transformer is among the key equipment of electrical power system for maintaining the continuity of transmission and distribution of power. Dissolved gas analysis (DGA) methods are accepted by utilities for condition monitoring and detecting incipient faults in transformers. The graphical DGA methods have gained popularity in the recent past. The three-gas and five-gas based graphical methods are regularly used and recently seven-gas and four-gas methods have been proposed. This work is based on six gases and a Hexagon method (HexM) is proposed. The HexM is tested for the IECTC 10 database for detection of six types of faults. None of the graphical methods proposed so far have a region defined for normal condition. In this method a region in the hexagon is earmarked for normal ageing, and samples from the published literature are used for testing it. The results of HexM are compared with generally used Duvals triangles and pentagons and the recently proposed heptagon method for fault type interpretation. The suggested technique is tested and compared with graphical methods. Based on the test samples, the Hexagon figure gives 93.6 % accuracy, Heptagon gives 84.9% accuracy.
- 22 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (4) , 2108-2115
A New Six-Gas-Based Fault Prediction Graphical Technique in Dissolved Gas Analysis for Oil-Immersed Power Transformer
Transformer is among the key equipment of electrical power system for maintaining the continuity of transmission and distribution of power. Dissolved gas analysis (DGA) methods are accepted by utilities for condition monitoring and detecting incipient faults in transformers. The graphical DGA methods have gained popularity in the recent past. The three-gas and five-gas based graphical methods are regularly used and recently seven-gas and four-gas methods have been proposed. This work is based on six gases and a Hexagon method (HexM) is proposed. The HexM is tested for the IECTC 10 database for detection of six types of faults. None of the graphical methods proposed so far have a region defined for normal condition. In this method a region in the hexagon is earmarked for normal ageing, and samples from the published literature are used for testing it. The results of HexM are compared with generally used Duvals triangles and pentagons and the recently proposed heptagon method for fault type interpretation. The suggested technique is tested and compared with graphical methods. Based on the test samples, the Hexagon figure gives 93.6 % accuracy, Heptagon gives 84.9% accuracy.
- Open Access
- 7 January 2025
- Published by Bilingual Publishing Group in Journal of Electronic & Information Systems
- Vol. 8 (1) , 1-14
Transformer Fault Diagnosis: A Shallow Learning Approach for DGA-Based Incipient Fault Detection
Power transformers are exposed to electrical, thermal, and mechanical stresses during operation, leading to the degradation of insulation and the generation of dissolved gases. Utilities use IEEE and IEC standards use dissolved gas analysis (DGA) to detect incipient faults in oil-filled in-service transformers. Traditional gas ratio-based DGA methods, at times inconclusive diagnoses, limiting their effectiveness in scheduling preventive maintenance. This study presents the application of a shallow learning Backpropagation Neural Network (BP-NN) for assessing the condition of normal ageing and classification of incipient faults in oil-immersed power transformers. The model is trained using the concentrations (ppm) of five key gases—H₂, CH₄, C₂H₂, C₂H₄, and C₂H₆—as input features. The classified condition of a transformer is normal ageing and five fault type, namely partial discharge, low-energy and high-energy discharges, and thermal faults across two varying temperature ranges. The data set used for the classification of incipient faults within transformers is that where the fault type is confirmed by physical inspection. The 256 samples used in this work are from published sources, including the IEC TC10 database. The results achieved by the BP-NN demonstrate its capability to accurately classify normal ageing and diagnose five types of faults. For evaluating the performance of the trained NN, the IEEE/IEC method of classification, the benchmark used is the actual fault type. The shallow network of pattern recognition successfully identified the presence of normal ageing and the five fault types. The performance of the test set is 94.73%. The results highlight the potential of BP-NNs for enhanced transformer condition monitoring and early fault detection. As more high-quality labelled data become available, the diagnostic accuracy and robustness of the model are expected to improve further.
- 7 January 2025
- Published by Bilingual Publishing Group in Journal of Electronic & Information Systems
- Vol. 8 (1) , 1-14
Open AccessTransformer Fault Diagnosis: A Shallow Learning Approach for DGA-Based Incipient Fault Detection
Power transformers are exposed to electrical, thermal, and mechanical stresses during operation, leading to the degradation of insulation and the generation of dissolved gases. Utilities use IEEE and IEC standards use dissolved gas analysis (DGA) to detect incipient faults in oil-filled in-service transformers. Traditional gas ratio-based DGA methods, at times inconclusive diagnoses, limiting their effectiveness in scheduling preventive maintenance. This study presents the application of a shallow learning Backpropagation Neural Network (BP-NN) for assessing the condition of normal ageing and classification of incipient faults in oil-immersed power transformers. The model is trained using the concentrations (ppm) of five key gases—H₂, CH₄, C₂H₂, C₂H₄, and C₂H₆—as input features. The classified condition of a transformer is normal ageing and five fault type, namely partial discharge, low-energy and high-energy discharges, and thermal faults across two varying temperature ranges. The data set used for the classification of incipient faults within transformers is that where the fault type is confirmed by physical inspection. The 256 samples used in this work are from published sources, including the IEC TC10 database. The results achieved by the BP-NN demonstrate its capability to accurately classify normal ageing and diagnose five types of faults. For evaluating the performance of the trained NN, the IEEE/IEC method of classification, the benchmark used is the actual fault type. The shallow network of pattern recognition successfully identified the presence of normal ageing and the five fault types. The performance of the test set is 94.73%. The results highlight the potential of BP-NNs for enhanced transformer condition monitoring and early fault detection. As more high-quality labelled data become available, the diagnostic accuracy and robustness of the model are expected to improve further.
- Open Access
- 1 March 2022
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1228 (1) , 012003
Hybridized and Complementary Comparative Analysis of Dissolved Gases in a Power Transformer
Power transformer is considered important equipment both in the transmission and distribution zone of electric power. Safety of power system elements plays a crucial role for enhancing its reliability. Transformer being a major component plays a much vital role and needs to be monitored and maintained at a regular basis. Transformer oil helps in performing the functions of insulation, cooling and helps extinguish arcs. Transformer oil also dissolves the gases which get generated by the degradation of oil, presence of moisture and gas from insulation deterioration of cellulose, gases and moisture from the surrounding, to which the oil is exposed. The dissolved gas present in an oil sample can be helpful in determining the nature of a fault which can vary according to gas types and its concentrations. DGA (Dissolved Gas Analysis) have been used as a suitable tool in enabling the reliability of the system and safety of the transformer for a long time. An analysis of Dissolved gases in oil is analytical method and have been used and interpreted differently by different methods and users. DGA methods using ratios, gas concentration and graphical methods have been presented in this work. The tools use mix of fuzzy based analysis, MATLAB. The basic motivation of the work is to create a platform for DGA analysis so as to provide early and easy detection and diagnosis of Transformer Failures.
- 1 March 2022
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1228 (1) , 012003
Open AccessHybridized and Complementary Comparative Analysis of Dissolved Gases in a Power Transformer
Power transformer is considered important equipment both in the transmission and distribution zone of electric power. Safety of power system elements plays a crucial role for enhancing its reliability. Transformer being a major component plays a much vital role and needs to be monitored and maintained at a regular basis. Transformer oil helps in performing the functions of insulation, cooling and helps extinguish arcs. Transformer oil also dissolves the gases which get generated by the degradation of oil, presence of moisture and gas from insulation deterioration of cellulose, gases and moisture from the surrounding, to which the oil is exposed. The dissolved gas present in an oil sample can be helpful in determining the nature of a fault which can vary according to gas types and its concentrations. DGA (Dissolved Gas Analysis) have been used as a suitable tool in enabling the reliability of the system and safety of the transformer for a long time. An analysis of Dissolved gases in oil is analytical method and have been used and interpreted differently by different methods and users. DGA methods using ratios, gas concentration and graphical methods have been presented in this work. The tools use mix of fuzzy based analysis, MATLAB. The basic motivation of the work is to create a platform for DGA analysis so as to provide early and easy detection and diagnosis of Transformer Failures.
- Open Access
- 1 April 2020
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1478 (1) , 012029
Assessment of the use of FEM for computation of Electromagnetic Forces, Losses and Design of Transformers
This paper reviews the published work on power transformers for assessment of the electrical, magnetic losses, and electromagnetic forces produced during normal and short circuit conditions. The different methods used are analytical method, integral equation method, boundary element method, and finite element method (FEM). The copper losses and eddy currents within the copper conductors/windings need to be assessed to estimate the heat generate and compute the efficiency. The knowledge of the eddy current losses in the core and stray losses in each component of the transformer can help in the design improvement. Earlier 2D FEM and now 3D FEM has been used to evaluate the electromagnetic flux under normal conditions, the effect of the in-rush phenomenon, assessment of mechanical strength of windings, insulation, computation of short circuit forces and need of the mechanical support components during fault conditions. This paper gives an overview of the work done on the computation of electromagnetic forces, losses, and design of transformers using FEM to assess the scope for further work.
- 1 April 2020
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1478 (1) , 012029
Open AccessAssessment of the use of FEM for computation of Electromagnetic Forces, Losses and Design of Transformers
This paper reviews the published work on power transformers for assessment of the electrical, magnetic losses, and electromagnetic forces produced during normal and short circuit conditions. The different methods used are analytical method, integral equation method, boundary element method, and finite element method (FEM). The copper losses and eddy currents within the copper conductors/windings need to be assessed to estimate the heat generate and compute the efficiency. The knowledge of the eddy current losses in the core and stray losses in each component of the transformer can help in the design improvement. Earlier 2D FEM and now 3D FEM has been used to evaluate the electromagnetic flux under normal conditions, the effect of the in-rush phenomenon, assessment of mechanical strength of windings, insulation, computation of short circuit forces and need of the mechanical support components during fault conditions. This paper gives an overview of the work done on the computation of electromagnetic forces, losses, and design of transformers using FEM to assess the scope for further work.