Salani U. Fernando
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Salani U. Fernando has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Chad W. Cuss
Laboratory for Environmental and Analytical Nanogeochemistry, Memorial University of Newfoundland (Grenfell Campus), Canada
3 shared publications Agil Azimzada
2 shared publicationsBjörn Meermann
2 shared publications- Claire M. Churchill
School of Science and the Environment, Grenfell Campus A
2 shared publications - Florian Meier
Postnova Analytics GmbH, Rankinestraße 1, 86899 Landsberg, Germany
2 shared publications Isabelle A. M. Worms
2 shared publications
Latest Publications
- Open Access
Solid–Water Extraction Ratio on Apparent Dissolved Trace Element Mobility and Nanoparticle Carriers in Soil Solutions
Solid–water extractions are widely used to collect soil solutions to evaluate trace element (TE) mobility and nanoparticle (NP) transport, and they also simulate changes in soil moisture associated with changing climate. However, differences in extraction ratios used to isolate dissolved (<0.45 μm) TEs may introduce methodological bias and limit comparability among studies. Here, we investigated how solid–water extraction ratios influence dissolved TE concentrations and their distribution among colloidal fractions. Three contrasting soils were examined: an agricultural podzol and two mining-related reclamation soils, overburden and a peat–mineral mixture. Soil solutions were extracted at ratios of 1:20, 1:10, and 1:5 and analyzed for dissolved Al, Mn, Fe, Cu, Pb, and U using inductively coupled plasma mass spectrometry (ICP-MS), while colloidal distributions were characterized using asymmetric flow field-flow fractionation coupled to a UV detector and ICP-MS. The 1:5 solid–water extraction resulted in higher apparent dissolved TE concentrations in the soil extracts and enhanced AF4 fractogram peak intensities. However, after correcting for dilution and normalizing to soil mass, Al and Fe mobilization was significantly lower at the 1:5 extraction ratio across all soils, whereas other elements showed more variable soil-dependent responses. These results demonstrate that the solid–water extraction ratio influences apparent TE mobility and the detectability of colloidal phases in soil solutions.
Open AccessSolid–Water Extraction Ratio on Apparent Dissolved Trace Element Mobility and Nanoparticle Carriers in Soil Solutions
Solid–water extractions are widely used to collect soil solutions to evaluate trace element (TE) mobility and nanoparticle (NP) transport, and they also simulate changes in soil moisture associated with changing climate. However, differences in extraction ratios used to isolate dissolved (<0.45 μm) TEs may introduce methodological bias and limit comparability among studies. Here, we investigated how solid–water extraction ratios influence dissolved TE concentrations and their distribution among colloidal fractions. Three contrasting soils were examined: an agricultural podzol and two mining-related reclamation soils, overburden and a peat–mineral mixture. Soil solutions were extracted at ratios of 1:20, 1:10, and 1:5 and analyzed for dissolved Al, Mn, Fe, Cu, Pb, and U using inductively coupled plasma mass spectrometry (ICP-MS), while colloidal distributions were characterized using asymmetric flow field-flow fractionation coupled to a UV detector and ICP-MS. The 1:5 solid–water extraction resulted in higher apparent dissolved TE concentrations in the soil extracts and enhanced AF4 fractogram peak intensities. However, after correcting for dilution and normalizing to soil mass, Al and Fe mobilization was significantly lower at the 1:5 extraction ratio across all soils, whereas other elements showed more variable soil-dependent responses. These results demonstrate that the solid–water extraction ratio influences apparent TE mobility and the detectability of colloidal phases in soil solutions.
- 5 November 2026
- Published by CSIRO Publishing in Environmental Chemistry
- Vol. 23 (7)
Complementary application of AF4-UV-ICP-MS and spICP-TOFMS for soil solution nanogeochemistry
Environmental context: Understanding how small particles in soil water carry nutrients and contaminants is essential for effective soil management and reducing environmental risks. To study these tiny particles, scientists need specialized techniques. In this study, two complementary techniques were used to better understand how nutrients and contaminants move and remain available in soil water, supporting sustainable soil management and ecosystem protection.
- 5 November 2026
- Published by CSIRO Publishing in Environmental Chemistry
- Vol. 23 (7)
Complementary application of AF4-UV-ICP-MS and spICP-TOFMS for soil solution nanogeochemistry
Environmental context: Understanding how small particles in soil water carry nutrients and contaminants is essential for effective soil management and reducing environmental risks. To study these tiny particles, scientists need specialized techniques. In this study, two complementary techniques were used to better understand how nutrients and contaminants move and remain available in soil water, supporting sustainable soil management and ecosystem protection.
- 11 September 2026
- Published by CSIRO Publishing in Environmental Chemistry
- Vol. 23 (6)
Corrigendum to : Development and analysis of a mixed colloid standard with trace elements using AF4-ICP-MS
- 11 September 2026
- Published by CSIRO Publishing in Environmental Chemistry
- Vol. 23 (6)
Corrigendum to : Development and analysis of a mixed colloid standard with trace elements using AF4-ICP-MS
- 18 August 2026
- Published by CSIRO Publishing in Environmental Chemistry
- Vol. 23 (5)
Development and analysis of a mixed colloid standard with trace elements using AF4-ICP-MS
Environmental context: Colloids are small, unstable particles that play important environmental roles in the transport of trace elements and can be analysed using asymmetrical flow field-flow fractionation (AF4) coupled to inductively coupled plasma–mass spectrometry (ICP-MS). A mixed colloid solution with trace elements was tested within and across laboratories to explore if the mixture can act as a reproducible, stable standard for measuring colloids with AF4-ICP-MS. Developing reference material is an essential step towards the characterisation of environmental colloids as it promotes the standardisation of techniques and interlaboratory collaboration.
- 18 August 2026
- Published by CSIRO Publishing in Environmental Chemistry
- Vol. 23 (5)
Development and analysis of a mixed colloid standard with trace elements using AF4-ICP-MS
Environmental context: Colloids are small, unstable particles that play important environmental roles in the transport of trace elements and can be analysed using asymmetrical flow field-flow fractionation (AF4) coupled to inductively coupled plasma–mass spectrometry (ICP-MS). A mixed colloid solution with trace elements was tested within and across laboratories to explore if the mixture can act as a reproducible, stable standard for measuring colloids with AF4-ICP-MS. Developing reference material is an essential step towards the characterisation of environmental colloids as it promotes the standardisation of techniques and interlaboratory collaboration.
- 18 July 2025
- Published by Wiley in Journal of Environmental Quality
- Vol. 54 (6) , 2084-2094
Improving trace element measurement accuracy: Lysimeter cleaning and material effects
Lysimeters are widely used to collect soil solutions with minimal disruption to the natural distribution of trace elements (TEs); however, sorption and release of TEs to and from lysimeter materials can introduce significant errors at trace concentrations. This study reports optimized cleaning protocols and evaluates TE sorption and release from three commonly used tension lysimeters: Rhizon MOM, SPE20 nylon, and SiC20. Cleaning involved sequential rinsing with acids and ultrapure water (UPW), followed by soaking and sonication in UPW. The sorption and release behaviors of lysimeters were evaluated before and after cleaning using soil leachate. Rhizon lysimeters cleaned more quickly than others due to lower residual TE concentrations. Blanks from Rhizon and SPE20 nylon lysimeters after cleaning generally showed low TE concentrations (1–100 ng L −1 ), except for Al, Fe, and Zn (>100 ng L −1 ), and Tl and Th (−1 ; Th 1 µg L −1 ) even after cleaning, and showed significant sorption and release of Al, Ag, Ba, Cd, Cs, Cu, Fe, Mn, Tl, V, and Zn. These results provide crucial information to assist researchers in selecting the right lysimeter and cleaning protocols depending on research objectives and desired detection limits.
- 18 July 2025
- Published by Wiley in Journal of Environmental Quality
- Vol. 54 (6) , 2084-2094
Improving trace element measurement accuracy: Lysimeter cleaning and material effects
Lysimeters are widely used to collect soil solutions with minimal disruption to the natural distribution of trace elements (TEs); however, sorption and release of TEs to and from lysimeter materials can introduce significant errors at trace concentrations. This study reports optimized cleaning protocols and evaluates TE sorption and release from three commonly used tension lysimeters: Rhizon MOM, SPE20 nylon, and SiC20. Cleaning involved sequential rinsing with acids and ultrapure water (UPW), followed by soaking and sonication in UPW. The sorption and release behaviors of lysimeters were evaluated before and after cleaning using soil leachate. Rhizon lysimeters cleaned more quickly than others due to lower residual TE concentrations. Blanks from Rhizon and SPE20 nylon lysimeters after cleaning generally showed low TE concentrations (1–100 ng L −1 ), except for Al, Fe, and Zn (>100 ng L −1 ), and Tl and Th (−1 ; Th 1 µg L −1 ) even after cleaning, and showed significant sorption and release of Al, Ag, Ba, Cd, Cs, Cu, Fe, Mn, Tl, V, and Zn. These results provide crucial information to assist researchers in selecting the right lysimeter and cleaning protocols depending on research objectives and desired detection limits.