Xiling Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Xiling Shi has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Jie Liang
State key Laboratory of Extreme Environment Optoelectronic Dynamic Testing Technology and Instrument, North University of China, Taiyuan, Shanxi 030051, China
1 shared publication - Tong Song
State key Laboratory of Extreme Environment Optoelectronic Dynamic Testing Technology and Instrument, North University of China, Taiyuan, Shanxi 030051, China
1 shared publication - Zhidong Zhang
Key Laboratory of Instrumentation Science & Dynamic Measurement of Ministry of Education, North University of China, Taiyuan 030051, China
1 shared publication
Latest Publications
- 25 April 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 13 (20) , 10356-10366
A flexible pressure sensor array based on an ionic gel for pulse detection
Flexible pressure sensors are widely applied in tactile sensing, gait testing, and wearable devices due to their flexibility and repeatability. However, measuring weaker signals needs ultrahigh sensitivity and an extensive detection range. Herein, we propose a novel ionic–electronic sensor featuring a cavity structure made up of Ag electrodes, a PDMS space layer, and an ionic gel. The latter was created by combining polyvinyl alcohol (PVA), chitosan (CS), and 1-ethyl-3-methylimidazole chloride (ionic liquid) after three freeze–thaw cycles. This sensor demonstrated remarkable maximum sensitivity of up to 48 584.56 kPa−1 within the range of 1–10 kPa, a broad pressure range of 0.1–200 kPa, and excellent repeatability over 1000 loading–unloading cycles. Owing to a capacitive effect, a sensor and array sensor were used to detect pulse signals and space pressure distribution, respectively. The signals of each channel of the array sensor were collected through a data-acquisition system. The main peak of the pulse wave was represented by a histogram, and a three-dimensional (3D) pulse wave shape was reconstructed. The 3D pulse wave provides the possibility for the extraction of waveform characteristics. In conclusion, our sensor could be used in portable wearable and flexible smart electronics.
- 25 April 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 13 (20) , 10356-10366
A flexible pressure sensor array based on an ionic gel for pulse detection
Flexible pressure sensors are widely applied in tactile sensing, gait testing, and wearable devices due to their flexibility and repeatability. However, measuring weaker signals needs ultrahigh sensitivity and an extensive detection range. Herein, we propose a novel ionic–electronic sensor featuring a cavity structure made up of Ag electrodes, a PDMS space layer, and an ionic gel. The latter was created by combining polyvinyl alcohol (PVA), chitosan (CS), and 1-ethyl-3-methylimidazole chloride (ionic liquid) after three freeze–thaw cycles. This sensor demonstrated remarkable maximum sensitivity of up to 48 584.56 kPa−1 within the range of 1–10 kPa, a broad pressure range of 0.1–200 kPa, and excellent repeatability over 1000 loading–unloading cycles. Owing to a capacitive effect, a sensor and array sensor were used to detect pulse signals and space pressure distribution, respectively. The signals of each channel of the array sensor were collected through a data-acquisition system. The main peak of the pulse wave was represented by a histogram, and a three-dimensional (3D) pulse wave shape was reconstructed. The 3D pulse wave provides the possibility for the extraction of waveform characteristics. In conclusion, our sensor could be used in portable wearable and flexible smart electronics.