LCLiang Chen

Liang Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Liang Chen has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Highly sensitive surface acoustic wave x-ray detector based on piezoelectric ε -phase gallium oxide film

    by Mingming Wang, Haoran Meng, Yujia Tu, Leidang Zhou, Xing Lu, Liang Chen, Wenyu Shu, Peipei Bai, Xiao Ouyang

    ε-phase gallium oxide (ε-Ga2O3), a wide-bandgap semiconductor with intrinsically high resistivity, radiation tolerance, and piezoelectric properties, enables the integration of surface acoustic wave (SAW) operation with x-ray detection, providing a frequency-domain sensing mechanism with enhanced noise immunity. In this work, a single-port resonant SAW x-ray detector based on an ε-Ga2O3 thin film grown on sapphire is demonstrated. The device employs submicrometer interdigital transducers to achieve GHz-frequency operation, exhibiting a Rayleigh-mode resonance at 1.35 GHz. Over x-ray dose rates ranging from 191 to 1149 mGy/s, both the resonance frequency shift and attenuation exhibit monotonic, theoretically consistent behavior governed by the acoustoelectric effect, enabling dual-parameter sensing of radiation-induced changes in conductivity. A high sensitivity of 1.58 ppm/Gy is achieved at 1149 mGy/s. The device also shows stable on–off switching and repeatable responses. Furthermore, compatibility with radio frequency systems makes the proposed device promising for passive wireless sensing and high-capacity multiplexed radiation detection applications.

  • Electrical characteristics and defect evolution in β -Ga2O3 Schottky barrier diodes under 14 MeV neutron irradiation

    by Puyu Zhai, Yushan Song, Liang Chen, Leidang Zhou, Hao Chen, Penghui Zhao, Xiaojing Song, Xiao Ouyang

    The effects of 14 MeV neutron irradiation on β-Ga2O3 Schottky barrier diodes (SBDs) were investigated at a fluence of 4.08 × 1014 cm−2. After irradiation, the forward current density decreased, and the specific on-resistance increased, whereas the reverse leakage current was suppressed, and the breakdown voltage increased. Capacitance–voltage (C–V) measurements revealed a pronounced reduction in the net carrier concentration, indicating irradiation-induced carrier compensation and an enlarged depletion region in β-Ga2O3. In contrast, the ideality factor (η) and Schottky barrier height (ΦB) showed only limited variations, suggesting that the observed electrical changes were not primarily caused by significant Schottky barrier degradation. Complementary material characterizations were performed to identify the defect-related origin of these electrical variations. Optical microscopy and atomic force microscopy revealed crack-like surface damage and increased nanoscale roughness after irradiation. Raman spectroscopy revealed reduced Raman intensity, positive peak shifts, and local stress perturbation, indicating irradiation-induced lattice distortion. X-ray photoelectron spectroscopy provided near-surface chemical evidence of Ga–O bonding perturbation and an enhanced contribution from oxygen-vacancy-related defect states. Photoluminescence and x-ray-excited optical luminescence analyses further showed increased defect-related luminescence contributions and enhanced defect-assisted recombination over different excitation depths. These results establish a consistent link among irradiation-induced morphological, structural, and chemical defect evolution, carrier compensation, defect-assisted recombination, and device-level electrical variation. The findings provide insight into the radiation response of β-Ga2O3 SBDs and the development of radiation-tolerant ultrawide-bandgap electronic devices.

  • Heavy-ion-induced degradation mechanisms and supercritical fluid recovery dynamics in Al2O3/ β -Ga2O3 metal-oxide-semiconductor capacitors

    by Puyu Zhai, Yushan Song, Liang Chen, Mingchao Yang, Leidang Zhou, Song Li, Songquan Yang, Teng Ma, Zhifeng Lei, Xiaoping Ouyang

    This study investigated heavy-ion irradiation effects on Al2O3/beta-gallium (β-Ga2O3) metal-oxide-semiconductor capacitors (MOSCAPs), which serve as essential building blocks for metal-oxide-semiconductor field effect transistors (MOSFETs), and evaluated the restorative efficacy of N2O-based supercritical fluid (SCF) treatment. Following tantalum (Ta) ion irradiation at a cumulative fluence of 4 × 107 ions/cm2, the net carrier concentration (Nd) degraded from 2.91 × 1016 to 1.92 × 1016 cm−3. The interface state density (Dit) and interface oxide trap charge density (Niot) exhibited a slight decrease due to heavy-ion-induced defect restructuring, while the effective oxide charge density (Neff) declined from 4.22 × 1011 to 3.87 × 1011 cm−2 via electron capture by oxygen vacancies in the oxide layer. Irradiation-induced latent tracks and a reduction in trap energy level (φt) from 1.72 to 1.62 eV led to a tenfold increase in leakage current and reduced breakdown voltage, with trap-assisted tunneling identified as the dominant transport mechanism. To mitigate these effects, N2O-based SCF treatments were employed to achieve recovery through mild nitridation and oxygen compensation. Initial SCF treatment increased φt to 1.78 eV, though persistent latent tracks limited the restoration of leakage characteristics. Subsequent SCF treatments further suppressed leakage current primarily by reducing electrically active trap density and passivating track-associated defects, despite a marginal decline in φt. Recovery saturation and Neff polarity reversal were observed during prolonged exposure, indicating complex charge dynamics. These findings elucidated heavy-ion damage physics in Al2O3/β-Ga2O3 MOS structures and defined SCF operational boundaries, providing a critical reference for predicting the operational lifetime of future radiation-tolerant MOSFETs.


  • A neutron spectrometer based on recoil proton track imaging for high-yield inertial confinement fusion primary deuterium–tritium neutrons

    by Yaodong Sang, Qingmin Zhang, Jinliang Liu, Haoxuan Guo, Silong Zhang, Kangfu Zhu, Naizhe Zhao, Shiyi He, Yapeng Zhang, Yang Li, et al.

    The energy spectra of primary deuterium–tritium (DT) neutrons provide essential information about the implosion performance in inertial confinement fusion (ICF) experiments. Recoil proton track imaging is a recently developed technique for measuring neutron energy spectra, which optically records the track image of recoil protons in a gas scintillator using high-performance imaging devices, then derives the neutron spectrum through an unfolding procedure. Here, focusing on the ICF primary DT neutrons with a yield of up to 1019, we design a neutron spectrometer based on this method. Considering the trade-off between energy resolution and detection efficiency, we optimize key system parameters, including recoil angle, recoil proton flight distance, aperture size, polyethylene foil thickness, and gas scintillator pressure through simulation, achieving a recoil proton conversion efficiency of 8.68×10−7 for 14.1 MeV neutrons. In addition, since the high-precision spectrum unfolding requires a high-quality track image, we specially design a large-aperture fixed-focus lens to enhance the efficiency of scintillation photon collection. Furthermore, we propose a realistic track image simulation method that combines Monte Carlo simulation with optical imaging simulation, allowing for a more accurate calculation of the neutron energy response. Based on the designed system, we simulate track images for mono-energetic neutrons, neutrons with spectra from National Ignition Facility ignition experiments, and neutrons with a Gaussian spectrum. The results demonstrate that high-quality track images can be obtained under the designed system. Subsequently, the spectrum unfolding for simulated track images corresponding to energy spectra is performed using MLEM and GRAVEL algorithms. The high quality of the unfolded spectra indicates that the recoil proton track imaging is a promising approach for diagnosing ICF primary DT neutron spectra.


  • Open Access

    Measurement of relative neutron energy response curve of plastic scintillator detector based on the back-n-white neutron source at CSNS

    by Yapeng Zhang, Jinlu Ruan, Liang Chen, Jianfu Zhang, Shiyi He, Kuo Zhao, Leidang Zhou, Silong Zhang, Naizhe Zhao, Yang Li, et al.

    The plastic scintillator detector is widely used to measure pulsed radiation fields, and a high-quality neutron energy response curve is crucial for accurately determining neutron yields. Traditionally, the neutron energy response curve can be obtained by the simulation of the performance of neutron detectors via the knowledge of the light yield of secondary particles or direct measuring energy response. Both methods record signals by a data acquisition system in the counting mode. This work establishes a new model to directly measure the energy response to neutrons of a plastic scintillator detector in current mode with white source spectra. The plastic scintillator detector can be triggered externally. There is no signal loss and dead time, and it is possible to calibrate the neutron detector with a high-intensity neutron source. Efficiencies can be determined at all energies simultaneously, and a rapid calibration of the plastic scintillator detector is available. To validate the experimental results, the theoretical values are obtained by Geant4 simulation, and the results reproduce the shapes of the experimental curves reasonably well. The neutron energy response curves of the detector show that when the thickness of the scintillator is reduced from 3 to 1 mm, the reduction ratio of gamma signal intensity is greater than that of neutron signal intensity, which leads to an increase in the neutron–gamma sensitivity ratio. Meanwhile, the thin scintillator thickness can obtain a somewhat flatter neutron energy response curve compared with other thicknesses.