Andrea Matamoros
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Andrea Matamoros has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Hrvoje Brkić
Faculty of Dental Medicine and Health, Department of Biophysics, Biology and Chemistry, J. J. Strossmayer University of Osijek, HR-31000 Osijek, Croatia
2 shared publications - Marijke De Saint-Hubert
Radiation protection Dosimetry and Calibration Expert Group, Belgian Nuclear Research Centre (SCK•CEN), Boeretang 200, Mol, 2400, BELGIUM
2 shared publications - Mladen Kasabašić
Faculty of Medicine MEFOS, Osijek, Croatia
2 shared publications A. Cravo Sa
Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, Campus Tecnológico e Nuclear, Estrada Nacional 10, Km 139.7, 2695-066 Bobadela LRS, Portugal; Center for Translational Health and Medical Biotechnology Research, School of Health, Polytechnic of Porto, Rua Dr. António Bernardino de Almeida, 400, 4200-072 Porto, Portugal
1 shared publication- A. Ivkovic
Faculty of Medicine MEFOS, Osijek, Croatia
1 shared publication A. Vukoja
Faculty of Dental Medicine and Health FDMZ, Osijek, Croatia
1 shared publication
Latest Publications
- Open Access
- 17 June 2026
- Published by Elsevier in Physica Medica
- Vol. 148, 105845
Fetal dose assessment in radiotherapy: A systematic review and results of survey on assessment tools and methods, dose ranges, optimization strategies and imaging dose
- 17 June 2026
- Published by Elsevier in Physica Medica
- Vol. 148, 105845
Open AccessFetal dose assessment in radiotherapy: A systematic review and results of survey on assessment tools and methods, dose ranges, optimization strategies and imaging dose
- 6 January 2026
- Published by Elsevier in Physica Medica
- Vol. 142, 105718
Validation of the Tena pregnancy phantom and fetal dose assessment in proton scanning beam therapy
- 6 January 2026
- Published by Elsevier in Physica Medica
- Vol. 142, 105718
Validation of the Tena pregnancy phantom and fetal dose assessment in proton scanning beam therapy
- 25 July 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (16)
Analysis of the mixed secondary radiation field in proton therapy using a Timepix detector
Objective: One major advantage of proton therapy (PT) over conventional photon radiotherapy is reduced dose delivered to normal tissue. However, the complexity of the secondary radiation field composed of a mixture of particles with a wide energy range makes its characterization a challenging task. Approach: Measurements with a miniaturized Timepix detector were carried out in three positions out-of-field (7.4 cm, 14.1 cm, and 18.5 cm from the isocenter), inside a phantom resembling a 5 year old undergoing proton pencil beam scanning treatment for a brain tumor. Total and particle-specific deposited energy, absorbed dose, and dose equivalent in water were calculated. Results were compared with thermoluminescent detectors (TLDs) measurements and Monte Carlo (MC) simulations modelling the experimental setup. Main results: The proton absorbed dose in water normalized to the target dose, ranged from 4.8 mGy/Gy to 65.5 µGy/Gy, while the gamma dose, which remained consistently lower, ranged between 88.4 µGy/Gy and 6.1 µGy/Gy. The measured dose equivalent varied between 6.3 mSv/Gy and 82.3 µSv/Gy. Good agreement was observed for the two farthest-locations when comparing the absorbed dose in water estimated by the MiniPIX Timepix detector with TLD measurements and MC simulations. However, the closest position showed an overestimation for both the absorbed dose and the dose equivalent, while the farthest position exhibited an underestimation for the dose equivalent. Significance: Out-of-field dosimetry in proton therapy is challenging due to the complexity of the secondary mixed radiation field. Multiple detectors are typically required, but many are too large for use in anthropomorphic phantoms. This study demonstrates that the MiniPIX Timepix detector can accurately determine absorbed dose, dose equivalent and particle-specific contributions (electrons/gammas, protons, and ions). Unlike passive detectors such as TLDs, it enables active measurements with high time resolution, allowing dose rates analysis. The results, validated through experimental data and MC simulations, support the detector’s potential for reliable out-of-field dose assessment and improved patient safety.
- 25 July 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (16)
Analysis of the mixed secondary radiation field in proton therapy using a Timepix detector
Objective: One major advantage of proton therapy (PT) over conventional photon radiotherapy is reduced dose delivered to normal tissue. However, the complexity of the secondary radiation field composed of a mixture of particles with a wide energy range makes its characterization a challenging task. Approach: Measurements with a miniaturized Timepix detector were carried out in three positions out-of-field (7.4 cm, 14.1 cm, and 18.5 cm from the isocenter), inside a phantom resembling a 5 year old undergoing proton pencil beam scanning treatment for a brain tumor. Total and particle-specific deposited energy, absorbed dose, and dose equivalent in water were calculated. Results were compared with thermoluminescent detectors (TLDs) measurements and Monte Carlo (MC) simulations modelling the experimental setup. Main results: The proton absorbed dose in water normalized to the target dose, ranged from 4.8 mGy/Gy to 65.5 µGy/Gy, while the gamma dose, which remained consistently lower, ranged between 88.4 µGy/Gy and 6.1 µGy/Gy. The measured dose equivalent varied between 6.3 mSv/Gy and 82.3 µSv/Gy. Good agreement was observed for the two farthest-locations when comparing the absorbed dose in water estimated by the MiniPIX Timepix detector with TLD measurements and MC simulations. However, the closest position showed an overestimation for both the absorbed dose and the dose equivalent, while the farthest position exhibited an underestimation for the dose equivalent. Significance: Out-of-field dosimetry in proton therapy is challenging due to the complexity of the secondary mixed radiation field. Multiple detectors are typically required, but many are too large for use in anthropomorphic phantoms. This study demonstrates that the MiniPIX Timepix detector can accurately determine absorbed dose, dose equivalent and particle-specific contributions (electrons/gammas, protons, and ions). Unlike passive detectors such as TLDs, it enables active measurements with high time resolution, allowing dose rates analysis. The results, validated through experimental data and MC simulations, support the detector’s potential for reliable out-of-field dose assessment and improved patient safety.