Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kaisheng Wu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers

    Interfacial shear behavior between precast UHPC girder and cast-in-place NC slab with large groove and rebars

    by Haibo Jiang, Kaisheng Wu, Ruyu Shen, Boxiang Li, Jie Xiao, Fan Mo, Yueqiang Tian


  • Open Access

    Experimental and Numerical Investigation on Flexural Behaviors of a 30 m Full-Scale Prestressed UHPC-NC Composite Box Girder

    by Chengan Zhou, Shengze Wu, Kaisheng Wu, Fan Mo, Haibo Jiang, Yueqiang Tian, Junfa Fang

    Ultra-high-performance concrete (UHPC) exhibits significantly superior compressive and tensile properties compared to conventional concrete, demonstrating substantial application potential in bridge engineering. This study conducted full-scale bending tests on a 30 m prestressed UHPC-NC composite box girder within an actual engineering context. The testing flexural capacity Mt=34,469.2 kN·m exceeded the design requirement Md=18,138.0 kN·m, with Mt/Md=1.90. Finite element modeling (FEM) was employed to analyze and predict experimental outcomes, revealing a simulated flexural capacity of approximately 37,597.1 kN·m. The finite element models further explored failure mode transitions governed by the loading position while the concentrated load-to-support distance exceeds 9.62 m (shear span to effective depth ratio λ = 6.3), and the box girder fails in flexure; while less than 9.62 m, the box girder fails in shear. The flexural capacity of the test girder was also estimated using Response-2000 software and the recommended formulas from the Chinese code T/CCES 27-2021 (Technical specification for ultra-high-performance concrete girder bridge). The Response-2000 software yielded a flexural capacity estimate of Mr=30,816.1 kN·m. The technical specification provided two estimating results: (with safety factors) Mu1=25,414.4 kN·m and (without safety factors)  Mu2=33,810.9 kN·m. All estimated values of Response-2000 and Chinese code were rationally conservative (Mr, Mu1, Mu2<Mt). Comparative analysis demonstrates that Abaqus FEM accurately simulates the flexural behavior of the prestressed UHPC-NC composite box girders. Both Response-2000 calculations and the Chinese code T/CCES 27-2021 provide critical references for similar applications of prestressed UHPC-NC composite box girders.


  • Open Access

    Experimental Study of the Interfacial Shear Behavior Between NRC and UHPC in UHPC-Jacketing Rehabilitation of Concrete Bridges

    by Kaisheng Wu, Ruyu Shen, Kaijie Luo, Fan Mo, Haibo Jiang, Haozhen Fang, Bingxiong Xian

    Ultra-High-Performance Concrete (UHPC) jacketing is an effective and innovative strengthening method in the renovation projects of concrete bridges. In December 2021, the UHPC-jacketing method was first applied to rehabilitate a seriously damaged bridge in the Changzhou Bridge rehabilitation project in Guangzhou, China. However, the interfacial shear behavior between the Normal Reinforced Concrete (NRC) substrate and UHPC is a crucial factor for the effectiveness of the UHPC-jacketing strengthening method. Therefore, four push-out specimens were designed in this paper to investigate the effects of the embedded bolt diameter (12 mm and 16 mm) and construction method (cast-in-place UHPC layer (ZJ group) and precast UHPC panels with infilled high-strength mortar (GJ group)) on the shear behavior of the NRC–UHPC interface. The results indicated that with the increased bolt diameter from 12 mm to 16 mm, the first peak load (P1) rose from 920.17 kN to 1048.07 kN (+13.9%) in the ZJ group and from 838.08 kN to 1204.20 kN (+43.7%) in the GJ group. The residual loads (Pr) of the GJ group were smaller than those of the ZJ group, at 41.9% and 30.2% lower for bolt diameters of 12 mm and 16 mm, respectively. The construction method of high-strength mortar filling was significantly influenced by the bolt diameter, with a diameter of 16 mm required to fully utilize its shear resistance. Predictions from ACI 318-19 underestimated experimental shear capacity by 70.6% on average, while AASHTO (2017) and Fib provided accurate estimations (within 9.8–10.9% of experimental values).