Magnus Benke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Magnus Benke has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Michael Kübler
3rd Institute of Physics, Zentrum für Angewandte Quantuntechnologie (ZAQuant), University of Stuttgart, Allmandring 13, Stuttgart 70569, Germany
3 shared publications - Jixing Zhang
3rd Institute of Physics, Zentrum für Angewandte Quantuntechnologie (ZAQuant), University of Stuttgart, Allmandring 13, Stuttgart 70569, Germany
2 shared publications Jörg Wrachtrup
3rd Institute of Physics, University of Stuttgart 1 , Allmandring 13, Stuttgart 70569
2 shared publications- Yihua Wang
3rd Institute of Physics, Zentrum für Angewandte Quantuntechnologie (ZAQuant), University of Stuttgart, Allmandring 13, Stuttgart 70569, Germany
2 shared publications - Andrew Mark Edmonds
Element Six Innovation, Fermi Avenue, Harwell Oxford, Didcot, Oxfordshire OX11 0QR, UK
1 shared publication - Ara Rahimpour
Helmholtz-Institut Mainz, GSI Helmholtzzentrum für Schwerionenforschung, Staudingerweg 18, Mainz 55128, Germany
1 shared publication
Latest Publications
- 18 September 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (38)
Human cardiac measurements with diamond magnetometers
The heart produces small magnetic signals, but detecting them without touching the body and without heavy shielding equipment remains a major challenge. In this study, we demonstrate a noninvasive method to measure these signals using compact quantum sensors made from diamond. These sensors operate at room temperature and can detect extremely weak magnetic fields produced by the heart, even outside highly shielded environments. By averaging signals over many heartbeats and using noise suppression techniques, we successfully recorded clear magnetocardiography traces. Although current measurements require averaging, our results show a clear path toward real-time detection. We also explored a gradiometry protocol for unshielded noisy environments, paving the way for contactless cardiac detection in challenging clinical conditions. This work points toward a path for using quantum sensors in practical medical diagnostics of the heart and brain.
- 18 September 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (38)
Human cardiac measurements with diamond magnetometers
The heart produces small magnetic signals, but detecting them without touching the body and without heavy shielding equipment remains a major challenge. In this study, we demonstrate a noninvasive method to measure these signals using compact quantum sensors made from diamond. These sensors operate at room temperature and can detect extremely weak magnetic fields produced by the heart, even outside highly shielded environments. By averaging signals over many heartbeats and using noise suppression techniques, we successfully recorded clear magnetocardiography traces. Although current measurements require averaging, our results show a clear path toward real-time detection. We also explored a gradiometry protocol for unshielded noisy environments, paving the way for contactless cardiac detection in challenging clinical conditions. This work points toward a path for using quantum sensors in practical medical diagnostics of the heart and brain.
- 16 March 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (11)
High-dynamic-range vector magnetometry in solid-state systems
Nitrogen vacancy (NV) center magnetometers offer theoretical advantages such as high sensitivity, wide dynamic range, and vector capability; however, achieving all these performance metrics simultaneously in a single device remains a significant challenge. Our study presents an NV-based vector magnetometry system optimized for high-sensitivity, wide-range magnetic field measurements to overcome this issue. Our approach utilizes a frequency-locking technique combined with frequency hopping, enabling robust tracking of resonance frequencies over a wide magnetic field range via a high-speed direct digital synthesizer. We achieve real-time vector field reconstruction with high temporal resolution by continuously monitoring the resonance frequency. The proposed system demonstrates significant improvements in dynamic range, sensitivity, and tracking speed, positioning it as an essential tool for a variety of quantum sensing applications.
- 16 March 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (11)
High-dynamic-range vector magnetometry in solid-state systems
Nitrogen vacancy (NV) center magnetometers offer theoretical advantages such as high sensitivity, wide dynamic range, and vector capability; however, achieving all these performance metrics simultaneously in a single device remains a significant challenge. Our study presents an NV-based vector magnetometry system optimized for high-sensitivity, wide-range magnetic field measurements to overcome this issue. Our approach utilizes a frequency-locking technique combined with frequency hopping, enabling robust tracking of resonance frequencies over a wide magnetic field range via a high-speed direct digital synthesizer. We achieve real-time vector field reconstruction with high temporal resolution by continuously monitoring the resonance frequency. The proposed system demonstrates significant improvements in dynamic range, sensitivity, and tracking speed, positioning it as an essential tool for a variety of quantum sensing applications.
- Open Access
- 18 August 2025
- Published by Elsevier in European Journal of Control
- Vol. 86
Adaptive modelling and filtering of periodic signals with non-stationary fundamental frequency
- 18 August 2025
- Published by Elsevier in European Journal of Control
- Vol. 86
Open AccessAdaptive modelling and filtering of periodic signals with non-stationary fundamental frequency