Arkadiy Klebaner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Arkadiy Klebaner has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Al Zeller
FRIB/NSCL Michigan State University East Lansing, MI, 48825, USA
1 shared publication - Andrew Dalesandro
Cryogenic Sector, Fermi National Accelerator Laboratory, Batavia, IL 60510, USA
1 shared publication G Burger
Field-portable Capillary Electrophoresis Instrument with Conductivity Detection H F Zhang X W Liu W Wang et al
1 shared publication- Gregory Nellis
University of Wisconsin, Madison
1 shared publication - J. G. Weisend
European Spallation Source
1 shared publication - Jennifer Marquardt
Ball Aerospace & Technologies Corp 1600 Commerce Street Boulder 80301 CO USA
1 shared publication
Latest Publications
- Open Access
Thermodynamic Analyses of the LCLS-II Cryogenic Distribution System
The Linac Coherent Light Source (LCLS) at Stanford Linear Accelerator Center (SLAC) is in the process of being upgraded to a superconducting radio frequency (SRF) accelerator and renamed LCLS-II. This upgrade requires thirty five 1.3 GHz SRF cryomodules (CM) and two 3.9 GHz CM. A cryogenic distribution system (CDS) is in development by Fermi National Accelerator Laboratory to interconnect the CM Linac with the cryogenic plant (CP). The CDS design utilizes cryogenic helium to support the CM operations with a high temperature thermal shield around 55 K, a low temperature thermal intercepts around 5 K, and a SRF cavity liquid helium supply and subatmospheric vapor return both around 2 K. Additionally the design must accommodate a Linac consisting of two parallel cryogenic strings, supported by two independent CP utilizing CDS components such as distribution boxes, transfer lines, feed caps and endcaps. The paper describes the overall layout of the cryogenic distribution system and the major thermodynamic factors which influence the CDS design including heat loads, pressure drops, temperature profiles, and pressure relieving requirements. In addition the paper describes how the models are created to perform the analyses.
Open AccessThermodynamic Analyses of the LCLS-II Cryogenic Distribution System
The Linac Coherent Light Source (LCLS) at Stanford Linear Accelerator Center (SLAC) is in the process of being upgraded to a superconducting radio frequency (SRF) accelerator and renamed LCLS-II. This upgrade requires thirty five 1.3 GHz SRF cryomodules (CM) and two 3.9 GHz CM. A cryogenic distribution system (CDS) is in development by Fermi National Accelerator Laboratory to interconnect the CM Linac with the cryogenic plant (CP). The CDS design utilizes cryogenic helium to support the CM operations with a high temperature thermal shield around 55 K, a low temperature thermal intercepts around 5 K, and a SRF cavity liquid helium supply and subatmospheric vapor return both around 2 K. Additionally the design must accommodate a Linac consisting of two parallel cryogenic strings, supported by two independent CP utilizing CDS components such as distribution boxes, transfer lines, feed caps and endcaps. The paper describes the overall layout of the cryogenic distribution system and the major thermodynamic factors which influence the CDS design including heat loads, pressure drops, temperature profiles, and pressure relieving requirements. In addition the paper describes how the models are created to perform the analyses.
- Open Access
- 18 December 2015
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 101 (1) , 011004
CEC Technical Editors
A list of the names and contact details of the CEC Technical Editors is available in the PDF.
- 18 December 2015
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 101 (1) , 011004
Open AccessCEC Technical Editors
A list of the names and contact details of the CEC Technical Editors is available in the PDF.