Carter B. Macdonald
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Carter B. Macdonald has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Aditya Bhattacharya
Department of Neuroscience Georgia Institute of Technology Atlanta Georgia USA
1 shared publication - Benjamin B. Risk
Department of Biostatistics and Bioinformatics, Emory University, Atlanta, Georgia, USA
1 shared publication - Candace C. Fleischer
Department of Radiology and Imaging Sciences Emory University School of Medicine Atlanta Georgia USA
1 shared publication Ralph Noeske
GE Healthcare Waukesha Wisconsin USA
1 shared publication- Sagar Mandava
GE Healthcare Waukesha Wisconsin USA
1 shared publication - Taylor M. Zuleger
Emory Sports Performance And Research Center (SPARC), Flowery Branch, GA, USA; Emory Sports Medicine Center, Atlanta, GA, USA; Department of Orthopaedics, Emory University School of Medicine, Atlanta, GA, USA; Department of Veterans Affairs, Atlanta VA Medical Center, Decatur, GA, USA
1 shared publication
Latest Publications
- Open Access
- 4 August 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 62 (6) , 1854-1865
Comparison of Magnetic Resonance Spectra Acquired With Hybrid PET / MR and Standalone MR Scanners
Background: The effect of the positron emission tomography (PET) modality in hybrid PET/MR scanners on MR spectral quality is unclear. Purpose: To evaluate spectral quality, quantification, and repeatability of brain MR spectroscopy (MRS) acquired on PET/MR and standalone MR scanners. Study Type: Prospective. Subjects: 23 healthy adults (male/female = 11/12, age = 27 ± 11 years). Field Strength/Sequence: 3T, semi‐localized by adiabatic selective refocusing. Assessment: Single voxel MR spectra were acquired with GE Signa PET/MR and Siemens Prisma Fit MR scanners in healthy volunteers, and additionally with a GE Premier MR scanner in vitro. Spectral quality, metabolite concentrations, and repeatability were evaluated. Statistical Tests: Linear mixed models assessed signal‐to‐noise ratio (SNR), full width at half maximum (FWHM), and metabolites/total creatine (tCr). Intraclass correlation coefficients (ICCs) determined repeatability; mean squared error (MSE) evaluated accuracy of quantification. Values are reported as mean ± standard deviation. Significance was determined by p ≤ 0.05. Results: In vivo spectra acquired using the Siemens standalone MR showed significantly higher SNR (PET/MR: 118.8 ± 19.1, MR: 132.2 ± 24.4) but significantly broader FWHM (PET/MR: 7.2 ± 1.8 Hz, MR: 8.4 ± 2.5 Hz) compared to PET/MR. All metabolite ratios were significantly higher in spectra acquired on the standalone MR. Within‐session repeatability was good (ICC > 0.75), and between‐session repeatability was moderate to excellent (ICC 0.5 to > 0.90) for all metabolites in vivo. In vitro spectra acquired with the PET/MR had significantly higher SNR (329.1 ± 46.1) than the Siemens standalone MR (150.8 ± 49.3) but significantly lower than the GE standalone MR (395.9 ± 33.7). The PET/MR produced narrower FWHM (2.1 ± 0.4 Hz) than the Siemens standalone MR (4.1 ± 1.7 Hz) but broader than the GE standalone MR (1.6 ± 0.1 Hz) and lower MSE for some metabolites. Data Conclusion: MR spectral quality appears uncompromised when acquired with hybrid PET/MR compared to standalone MR.
- 4 August 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 62 (6) , 1854-1865
Open AccessComparison of Magnetic Resonance Spectra Acquired With Hybrid PET / MR and Standalone MR Scanners
Background: The effect of the positron emission tomography (PET) modality in hybrid PET/MR scanners on MR spectral quality is unclear. Purpose: To evaluate spectral quality, quantification, and repeatability of brain MR spectroscopy (MRS) acquired on PET/MR and standalone MR scanners. Study Type: Prospective. Subjects: 23 healthy adults (male/female = 11/12, age = 27 ± 11 years). Field Strength/Sequence: 3T, semi‐localized by adiabatic selective refocusing. Assessment: Single voxel MR spectra were acquired with GE Signa PET/MR and Siemens Prisma Fit MR scanners in healthy volunteers, and additionally with a GE Premier MR scanner in vitro. Spectral quality, metabolite concentrations, and repeatability were evaluated. Statistical Tests: Linear mixed models assessed signal‐to‐noise ratio (SNR), full width at half maximum (FWHM), and metabolites/total creatine (tCr). Intraclass correlation coefficients (ICCs) determined repeatability; mean squared error (MSE) evaluated accuracy of quantification. Values are reported as mean ± standard deviation. Significance was determined by p ≤ 0.05. Results: In vivo spectra acquired using the Siemens standalone MR showed significantly higher SNR (PET/MR: 118.8 ± 19.1, MR: 132.2 ± 24.4) but significantly broader FWHM (PET/MR: 7.2 ± 1.8 Hz, MR: 8.4 ± 2.5 Hz) compared to PET/MR. All metabolite ratios were significantly higher in spectra acquired on the standalone MR. Within‐session repeatability was good (ICC > 0.75), and between‐session repeatability was moderate to excellent (ICC 0.5 to > 0.90) for all metabolites in vivo. In vitro spectra acquired with the PET/MR had significantly higher SNR (329.1 ± 46.1) than the Siemens standalone MR (150.8 ± 49.3) but significantly lower than the GE standalone MR (395.9 ± 33.7). The PET/MR produced narrower FWHM (2.1 ± 0.4 Hz) than the Siemens standalone MR (4.1 ± 1.7 Hz) but broader than the GE standalone MR (1.6 ± 0.1 Hz) and lower MSE for some metabolites. Data Conclusion: MR spectral quality appears uncompromised when acquired with hybrid PET/MR compared to standalone MR.