VGVinay Gupta

Vinay Gupta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Vinay Gupta has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comprehensive device optimization and thermal stability investigation of mixed-cation (FAPbI₃)₀.₉₅(MAPbBr₃)₀.₀₅ perovskite solar cells using SCAPS-1D

    by Sakshi Sharma, Jai Govind Singh, Rupendra Kumar Pachauri, Vinay Gupta

    Nowadays, lead halide perovskite material has gained considerable interest among researchers because of its outstanding properties like excellent absorption coefficient, abundant availability and extreme defect tolerance. Perovskite solar cells are made up of an absorber layer inserted between the electron transport layer (ETL) and hole transport layer (HTL). Previously, the scientists had announced power conversion efficiency (PCE) of 26.48% in lead halide based perovskite solar cells (PSCs). But the thickness of the absorber layer, the density of defect at the interface, the doping density and operating temperature of the device influence the performance of PSC. Narrow-bandgap halide (NBH) based perovskite solar cell with the absorber layer of (FAPbI3)0.95(MAPbBr3)0.05, TiO2 (electron transport layer) and P3HT (hole transport layer) are designed and simulated in this work. Firstly, the device is analyzed by varying the thickness of the absorber layer from 250 nm to 550 nm, which yields a maximum Jsc of 28.08 mA/cm2 and a PCE of 16.94% at 550 nm. Further results have been analyzed by varying the interface defect density at the ETL/NBH and NBH/HTL interfaces from 1 × 10 9 cm − 2 to 1 × 10 14 cm − 2 , yielding J sc of 24.08 mA/cm2 and PCE of 16.56% at 1 × 10 9 cm − 2 on the NBH/HTL interface. Moreover, the analysis was carried out by varying the doping densities of both the electron transport layer (ETL) and the hole transport layer (HTL) from 1 × 10 14 cm − 3 to 1 × 10 18 cm − 3 , yielding a J sc of 24.09 mA/cm 2 and a PCE of 15.64%. Furthermore, the effect of operating temperature on the NBH-based PSC absorber layer is also examined over the range of 270 K to 300 K to assess the environmental impact. The overall examination of NBH-based PSC enhanced the device’s efficiency by 16.13%. These observations can also be applied to lead-free halide perovskite solar cells and tandem applications.

  • Open Access

    Twin perturbation parameter based flexible power point tracking technique for grid-connected PV systems

    by Sakshi Sharma, Rupendra Kumar Pachauri, Piyush Kuchhal, Jyoti Joshi, Vinay Gupta, Vibhu Jately

    Photovoltaic (PV) systems are fundamentally designed in two main configurations: standalone and grid-tied architectures. Although Maximum Power Point Tracking (MPPT) is commonly implemented to optimize energy extraction from photovoltaic systems, it may jeopardize grid stability in the event of voltage or frequency fluctuations by compelling maximum power injection. To tackle this challenge, Flexible Power Point Tracking (FPPT) has surfaced as a viable solution that improves grid stability in grid-connected PV systems. This research introduces an efficient FPPT algorithm that is optimized for grid-connected photovoltaic systems. The suggested algorithm incorporates two control strategies: current regulation on the left side and voltage regulation on the right side of the power-voltage (P–V) curve so named as twin perturbation parameter (TPP). This method led to rapid convergence towards the FPP, thereby enhancing the algorithm''s efficiency. Simulations were performed at varying irradiance levels of 1000 W/m 2 and 500 W/m 2 , incorporating abrupt changes in irradiance. The proposed method shows 0.6% and 0.8% steady state oscillations for the abrupt change in irradiance conditions respectively. Further, the findings indicate that the introduced drift-free FPPT algorithm reaches an impressive tracking efficiency of 99.87%, with a response time of merely 3 ms, surpassing current leading technique by 1.5% and power technique by 3.2%. This method is appropriate for real-world application in advanced photovoltaic inverters.

  • Open Access

    Machine learning-based prediction of soiling losses in photovoltaic modules under different cleaning frequencies: an experimental investigation

    by Ashutosh Shukla, Rupendra Kumar Pachauri, Ranjan Walia, Vinay Gupta

    Accumulation of dust on solar panels lowers performance and limits energy production, particularly in dry locations. Dust accumulation on photovoltaic panels diminishes performance and reduces energy output, especially in arid regions. This study uses four identical modules in Roorkee, India, from October to December to examine the impact of cleaning frequency on photovoltaic (PV) performance. The reference panel is cleaned daily, while the remaining panels are cleaned weekly, biweekly, and monthly. Alongside short-circuit current measurements, environmental parameters including global horizontal irradiance, ambient temperature, wind speed, and relative humidity are continuously recorded. In this study, soiling loss (%) is examined as the primary performance indicator under various cleaning intervals to observe dust accumulation progression and its impact on the performance of the solar photovoltaic module. Experimental data are utilized to develop an empirical regression model that describes the trend of dust accumulation. The daily average soiling loss ranges between 0.17 and 0.21%. Furthermore, machine learning models, including Decision Tree, K-Nearest Neighbour, support vector regression, artificial neural network, and a stacking ensemble method, are developed for accurate prediction of soiling loss from environmental variables and cleaning frequency. The stacking model consistently achieves the best performance across all months, with root mean square error as low as 0.03–0.045, mean absolute error below 0.03, and R² = 0.999 compared to other models. Moreover, statistical analyses such as Bland–Altman plots and the Wilcoxon signed-rank test are employed to validate the significance and agreement of the predicted outcomes. The study highlights the benefits of data-driven solutions for predictive operation and maintenance of solar photovoltaic systems and provides valuable insights into the impact of cleaning frequency on reducing soiling losses.


  • Machine Learning-Based Forecasting of Global Horizontal Irradiance for Solar Energy Applications

    by Nitin Kumar, Vinay Gupta, Priyanka Sharma, Khadiza Akter, Ankur Kumar Gupta, Rupendra Kumar Pachauri


  • Top Cited Papers
    Open Access

    Multi-class classification of brain tumors using optimized CNN and transfer learning techniques

    by Vatsala Anand, Ajay Khajuria, Rupendra Kumar Pachauri, Vinay Gupta

    Brain tumors are abnormal cell growths within the brain or central nervous system that disrupt normal brain function and can be life-threatening. Early detection and precise classification of brain tumors are critical for effective treatment and improved patient prognosis. In this research, a Convolutional Neural Networks model with four convolution blocks is proposed for automated brain tumor detection and classification. The proposed scheme is applied to four types of MRI images, i.e., glioma tumor, meningioma tumor, no tumor, and pituitary tumor. The proposed architecture is optimized using the Adam optimizer, and the model is trained to minimize cross-entropy loss, enhancing classification accuracy across all four categories. The proposed model is compared with the three transfer learning models namely ResNet50, VGG19 and DenseNet121. Out of these models the proposed CNN model has outperformed with the value of accuracy as 98.5%, followed by second best accuracy at ResNet50 with value as 93.2%. After that, the category-wise analysis is performed on the proposed CNN model. Category 0 is numbered as Glioma, Category 1 as Meningioma, Category 2 as Pituitary, and Category 3 as No_tumor. Category 3 has obtained the highest value of accuracy as 0.98, followed by 0.96, 0.89 and 0.86 in category 2, category 1 and category 0 respectively. This analysis improves diagnostic accuracy for brain tumors and has the potential to aid radiologists in clinical settings.


  • Open Access

    Optimized machine learning based comparative analysis of predictive models for classification of kidney tumors

    by Vatsala Anand, Ajay Khajuria, Rupendra Kumar Pachauri, Vinay Gupta

    The kidney is an important organ that helps clean the blood by removing waste, extra fluids, and harmful substances. It also keeps the balance of minerals in the body and helps control blood pressure. But if the kidney gets sick, like from a tumor, it can cause big health problems. Finding kidney issues early and knowing what kind of problem it has is very important for good treatment and better results for patients. In this study, different machine learning models were used to detect and classify kidney tumors. These models included Decision Tree, XGBoost Classifier, K-Nearest Neighbors (KNN), Random Forest, and Support Vector Machine (SVM). The dataset splitting is done in two ways 80:20 and 75:25 and the models worked best with the 80:20 split. Among them, the top three models—SVM, KNN, and XGBoost—were tested with different batch sizes, which are 16 and 32. SVM performed best when the batch size was 32. These models were also trained using two types of optimizers, called Adam and SGD. SVM did better when using the Adam method. SVM had the highest accuracy of 98. 5%, then came KNN with 90.4%. This method will help healthcare professionals in the early diagnosis of disease.