Claudia-Gabriela Mateias
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Claudia-Gabriela Mateias has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Alexandru-Titus Farcasiu
Department of Prosthodontics, Faculty of Dentistry, “Carol Davila” University of Medicine and Pharmacy, 37 Dionisie Lupu Street, District 2, 020021 Bucharest, Romania
2 shared publications - Ana Maria Cristina Țâncu
Discipline of Prosthodontics, Faculty of Dentistry, “Carol Davila” University of Medicine and Pharmacy, 37 Dionisie Lupu Street, District 2, 020021 Bucharest, Romania
2 shared publications - Lucian Toma Ciocan
Discipline of Dental Prosthesis Technology, Faculty of Dentistry, “Carol Davila” University of Medicine and Pharmacy, 37 Dionisie Lupu Street, District 2, 020021 Bucharest, Romania
2 shared publications - Marina Imre
Department of Prosthodontics, Faculty of Dentistry, “Carol Davila” University of Medicine and Pharmacy, 37 Dionisie Lupu Street, District 2, 020021 Bucharest, Romania
2 shared publications - Adela Banciu
Faculty of Medical Engineering, National University of Science and Technology Politehnica Bucharest, 1-7 Gh. Polizu Street, District 1, 011061 Bucharest, Romania
1 shared publication - Adrian Ionut Nicoara
Department of Science and Engineering of Oxide Materials and Nanomaterials, Faculty of Chemical Engineering and Biotechnologies, National University of Science and Technology POLITEHNICA Bucharest, 1-7 Gheorghe Polizu, 011061 Bucharest, Romania
1 shared publication
Latest Publications
- Open Access
- 26 November 2026
- Published by MDPI AG in Preprints.org
Digital Altered Cast for a Mandibular Distal Extension Removable Partial Denture: Technical Proof-of-Concept and Workflow
Recording the mucosa of distal extension ridges remains difficult in digital prosthodontics. Digital adaptations of the altered cast technique still depend on a plaster cast or a separate tray, or on a printed tray bonded to the framework. This technical report describes a variation in which the framework itself carries the impression and the altered cast is built virtually from scans, without a stone cast or a printed tray. A woman with a mandibular Kennedy Class I partial edentulism was treated. A cobalt-chromium framework was fabricated by selective laser melting from an intraoral scan. Thermoplastic compound was border-molded on the saddles and washed with a low-consistency condensation silicone. The framework with the impression was scanned intraorally and then in a laboratory scanner, and the scans were aligned manually using 14 dental and 18 framework landmarks. The mucosal surfaces of the distal extensions were isolated, their normals reversed, and the surfaces merged with the preliminary scan to produce a printed functional model. Compared with the preliminary scan, the ridge surfaces showed mean deviations of −0.382 mm (right) and −0.142 mm (left), with 6.30% and 8.96% of points within ±0.05 mm; the remaining teeth, used for registration, agreed within ±0.05 mm for 99.84% of points. Without a reference of known accuracy, tissue displacement could not be separated from scanning and alignment error. The denture was in-serted without chairside adjustment, needed minor lingual flange adjustments at 24 and 48 h, and required no relining or repair over 12 months. The workflow was feasible in one patient; its accuracy and clinical benefit remain to be tested.
- 26 November 2026
- Published by MDPI AG in Preprints.org
Open AccessDigital Altered Cast for a Mandibular Distal Extension Removable Partial Denture: Technical Proof-of-Concept and Workflow
Recording the mucosa of distal extension ridges remains difficult in digital prosthodontics. Digital adaptations of the altered cast technique still depend on a plaster cast or a separate tray, or on a printed tray bonded to the framework. This technical report describes a variation in which the framework itself carries the impression and the altered cast is built virtually from scans, without a stone cast or a printed tray. A woman with a mandibular Kennedy Class I partial edentulism was treated. A cobalt-chromium framework was fabricated by selective laser melting from an intraoral scan. Thermoplastic compound was border-molded on the saddles and washed with a low-consistency condensation silicone. The framework with the impression was scanned intraorally and then in a laboratory scanner, and the scans were aligned manually using 14 dental and 18 framework landmarks. The mucosal surfaces of the distal extensions were isolated, their normals reversed, and the surfaces merged with the preliminary scan to produce a printed functional model. Compared with the preliminary scan, the ridge surfaces showed mean deviations of −0.382 mm (right) and −0.142 mm (left), with 6.30% and 8.96% of points within ±0.05 mm; the remaining teeth, used for registration, agreed within ±0.05 mm for 99.84% of points. Without a reference of known accuracy, tissue displacement could not be separated from scanning and alignment error. The denture was in-serted without chairside adjustment, needed minor lingual flange adjustments at 24 and 48 h, and required no relining or repair over 12 months. The workflow was feasible in one patient; its accuracy and clinical benefit remain to be tested.
- Open Access
- 20 August 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (8) , 421
In Vitro Cytotoxicity of Three Dimethacrylate-Based Photopolymer Resins for 3D-Printed Dental Restorations: A Qualitative Morphological Screening on Human Fibroblasts
The rapid adoption of vat photopolymerization (3D printing) in restorative and prosthetic dentistry has outpaced the independent biological characterization of the dimethacrylate resins on which it relies, even though incompletely converted networks can release residual monomers that are cytotoxic to the adjacent oral tissues. This study reports a qualitative in vitro cytotoxicity screening of three commercial photopolymer resins optimized for additive manufacturing: a general-purpose resin (ANYCUBIC) and two resins with a declared dental indication (TEMP PRINT and V-PRINT) performed according to the morphological evaluation described in ISO 10993-5. Aqueous extracts were prepared following ISO 10993-12 and applied to normal human fibroblasts (BJ line, ATCC CRL-2522) at 100% and 50% concentration for 24 h; morphological reactivity was graded on the standardized 0–4 scale by inverted light microscopy against an unexposed control, and supported by a semi-quantitative visual estimate of the proportion of affected cells. All three materials produced a concentration-dependent response. TEMP PRINT retained the best cellular compatibility (grade 1 at 50%, grade 2 at 100%), V-PRINT was intermediate, and ANYCUBIC showed the most pronounced reactivity (approaching grade 3 at 100%), giving an estimated cytotoxicity order of ANYCUBIC > V-PRINT > TEMP PRINT. As a qualitative morphological screening, the findings indicate that the dental-grade resins elicited a milder fibroblast response than the general-purpose photopolymer and support the recommendation that general-purpose resins should not be substituted for certified materials in intraoral use. Confirmation by quantitative viability assays with independent replicates is required before firm conclusions are drawn. In line with the qualitative nature of ISO 10993-5 morphological screening, the reported proportions of morphologically affected cells represent visual scoring rather than direct measurements of cell viability, and the study is therefore presented as an initial biological screening.
- 20 August 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (8) , 421
Open AccessIn Vitro Cytotoxicity of Three Dimethacrylate-Based Photopolymer Resins for 3D-Printed Dental Restorations: A Qualitative Morphological Screening on Human Fibroblasts
The rapid adoption of vat photopolymerization (3D printing) in restorative and prosthetic dentistry has outpaced the independent biological characterization of the dimethacrylate resins on which it relies, even though incompletely converted networks can release residual monomers that are cytotoxic to the adjacent oral tissues. This study reports a qualitative in vitro cytotoxicity screening of three commercial photopolymer resins optimized for additive manufacturing: a general-purpose resin (ANYCUBIC) and two resins with a declared dental indication (TEMP PRINT and V-PRINT) performed according to the morphological evaluation described in ISO 10993-5. Aqueous extracts were prepared following ISO 10993-12 and applied to normal human fibroblasts (BJ line, ATCC CRL-2522) at 100% and 50% concentration for 24 h; morphological reactivity was graded on the standardized 0–4 scale by inverted light microscopy against an unexposed control, and supported by a semi-quantitative visual estimate of the proportion of affected cells. All three materials produced a concentration-dependent response. TEMP PRINT retained the best cellular compatibility (grade 1 at 50%, grade 2 at 100%), V-PRINT was intermediate, and ANYCUBIC showed the most pronounced reactivity (approaching grade 3 at 100%), giving an estimated cytotoxicity order of ANYCUBIC > V-PRINT > TEMP PRINT. As a qualitative morphological screening, the findings indicate that the dental-grade resins elicited a milder fibroblast response than the general-purpose photopolymer and support the recommendation that general-purpose resins should not be substituted for certified materials in intraoral use. Confirmation by quantitative viability assays with independent replicates is required before firm conclusions are drawn. In line with the qualitative nature of ISO 10993-5 morphological screening, the reported proportions of morphologically affected cells represent visual scoring rather than direct measurements of cell viability, and the study is therefore presented as an initial biological screening.
- Open Access
- 9 April 2025
- Published by Romanian Association of Oral Rehabilitation in Romanian Journal of Oral Rehabilitation
- Vol. 17 (2) , 242-251
THE INCLUSION OF NANOPARTICLES IN THE MANUFACTURING OF 3D PRINTED COMPLETE DENTURES - A REVIEW OF CURRENT LITERATURE
Incorporating nanoparticles into the resin used for 3D printing represents a novel approach to counteracting the limitations of the material. Thus, this review is structured to address the interaction between the inorganic nanoparticles and organic matrix and to critically analyze the impact of various nanoparticles on the qualities of the resin. Furthermore, it examines the cytocompatibility and antibacterial properties gained by the inclusion of nanoparticles. The study concludes that, provided the percentage of nanoparticles does not exceed the saturation level of inter-polymeric chains, inorganic nanoparticles can improve the mechanical, physical, and antibacterial properties of the resin used for 3D printed complete dentures.
- 9 April 2025
- Published by Romanian Association of Oral Rehabilitation in Romanian Journal of Oral Rehabilitation
- Vol. 17 (2) , 242-251
Open AccessTHE INCLUSION OF NANOPARTICLES IN THE MANUFACTURING OF 3D PRINTED COMPLETE DENTURES - A REVIEW OF CURRENT LITERATURE
Incorporating nanoparticles into the resin used for 3D printing represents a novel approach to counteracting the limitations of the material. Thus, this review is structured to address the interaction between the inorganic nanoparticles and organic matrix and to critically analyze the impact of various nanoparticles on the qualities of the resin. Furthermore, it examines the cytocompatibility and antibacterial properties gained by the inclusion of nanoparticles. The study concludes that, provided the percentage of nanoparticles does not exceed the saturation level of inter-polymeric chains, inorganic nanoparticles can improve the mechanical, physical, and antibacterial properties of the resin used for 3D printed complete dentures.