Jianfeng Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jianfeng Guo has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Gang Li
Department of Ultrasound, The Affiliated Yixing Hospital of Jiangsu University, Wuxi, Jiangsu Province, China
1 shared publication - Xiufeng Yin
Department of Gynaecology and Obstetrics, The Affiliated Yixing Hospital of Jiangsu University, Wuxi, Jiangsu Province, China
1 shared publication - Yeping He
Department of Ultrasound, The Affiliated Yixing Hospital of Jiangsu University, Wuxi, Jiangsu Province, China
1 shared publication
Latest Publications
- Open Access
- 15 August 2025
- Published by Wolters Kluwer Health in Medicine
- Vol. 104 (33) , e43776
Prenatal suspicion and ultrasound diagnosis of umbilical artery thrombosis: A case report with targeted Doppler evaluation and timely delivery
Rationale: Umbilical artery thrombosis (UAT) is a rare complication that is strongly associated with adverse neonatal outcomes, and the diagnosis and selection of an appropriate delivery time for good neonatal outcomes is challenging. Here, we present a case of prenatal suspicion and ultrasound diagnosis of UAT: a case report with targeted Doppler evaluation and timely delivery. Patient concerns: A 35-year-old (gravida 6, para 1) with reduced fetal movement at 32 weeks gestation, Doppler ultrasound showed that for gestational age, the pulsatility index (PI), resistance index, and peak systolic velocity/end-diastolic velocity ratio of the umbilical artery (UA), PI of the left uterine artery, and PI of the middle cerebral artery were all <5th centile; the systolic/atrial wave ratio of the ductus venosus was 50th to 95th centile. Then the examination focused on the umbilical cord, excessive torsion of the umbilical cord and 2 hyperechoic lesions in 1 UA were observed. Only 1 UA was detected in the bladder section by color Doppler flow, whereas previous ultrasound screening results in the mid-trimester showed 2 umbilical arteries in the same section. Additionally, electronic heart rate monitoring revealed a noncontractile stimulation test abnormality. Diagnoses: UAT with fetal and hemodynamic changes were observed. Interventions: Urgent cesarean section was performed 2 days later after comprehensive prenatal counseling. Outcomes: The infant was born alive at 1740 g, and Apgar scores were 9-10-10 in 1-5-10 minutes respectively. Postoperative recovery of the pregnant woman was unremarkable. Lessons: Targeted Doppler evaluation and timely delivery are helpful for the diagnosis of UAT and obtaining a fine pregnancy result.
- 15 August 2025
- Published by Wolters Kluwer Health in Medicine
- Vol. 104 (33) , e43776
Open AccessPrenatal suspicion and ultrasound diagnosis of umbilical artery thrombosis: A case report with targeted Doppler evaluation and timely delivery
Rationale: Umbilical artery thrombosis (UAT) is a rare complication that is strongly associated with adverse neonatal outcomes, and the diagnosis and selection of an appropriate delivery time for good neonatal outcomes is challenging. Here, we present a case of prenatal suspicion and ultrasound diagnosis of UAT: a case report with targeted Doppler evaluation and timely delivery. Patient concerns: A 35-year-old (gravida 6, para 1) with reduced fetal movement at 32 weeks gestation, Doppler ultrasound showed that for gestational age, the pulsatility index (PI), resistance index, and peak systolic velocity/end-diastolic velocity ratio of the umbilical artery (UA), PI of the left uterine artery, and PI of the middle cerebral artery were all <5th centile; the systolic/atrial wave ratio of the ductus venosus was 50th to 95th centile. Then the examination focused on the umbilical cord, excessive torsion of the umbilical cord and 2 hyperechoic lesions in 1 UA were observed. Only 1 UA was detected in the bladder section by color Doppler flow, whereas previous ultrasound screening results in the mid-trimester showed 2 umbilical arteries in the same section. Additionally, electronic heart rate monitoring revealed a noncontractile stimulation test abnormality. Diagnoses: UAT with fetal and hemodynamic changes were observed. Interventions: Urgent cesarean section was performed 2 days later after comprehensive prenatal counseling. Outcomes: The infant was born alive at 1740 g, and Apgar scores were 9-10-10 in 1-5-10 minutes respectively. Postoperative recovery of the pregnant woman was unremarkable. Lessons: Targeted Doppler evaluation and timely delivery are helpful for the diagnosis of UAT and obtaining a fine pregnancy result.