Qiang Jia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qiang Jia has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Cuicui Chen
Guangzhou Youdi Bio-Technology Co., Ltd., Guangzhou 510663, China; Jinan Laide Bio-technology Co., Ltd., Jinan 271100, China
4 shared publications Huankun Liang
Guangzhou Youdi Bio-Technology Co., Ltd., Guangzhou 510663, China
4 shared publicationsHongrui Lai
Guangzhou Youdi Bio-Technology Co., Ltd., Guangzhou 510663, China
3 shared publicationsLaiqing Li
College of Food and Health, Guangzhou City Polytechnic, Guangzhou 510405, China
3 shared publicationsYanhong Lu
Guangzhou Youdi Biotechnology Co., Ltd., Guangzhou 510700, China
3 shared publicationsGuiling Guo
Guangzhou Youdi Bio-Technology Co., Ltd., Guangzhou 510663, China
1 shared publication
Latest Publications
- 20 November 2025
- Published by Elsevier in Journal of Virological Methods
- Vol. 340, 115302
Development of a dual-label time-resolved fluorescence immunoassay platform for simultaneous detection of canine distemper virus and parvovirus
- 20 November 2025
- Published by Elsevier in Journal of Virological Methods
- Vol. 340, 115302
Development of a dual-label time-resolved fluorescence immunoassay platform for simultaneous detection of canine distemper virus and parvovirus
- 30 September 2025
- Published by Elsevier in Food Chemistry
- Vol. 495 (Pt 3) , 146578
Quantitative determination of salbutamol residues using a fluorescence immunochromatography assay
- 30 September 2025
- Published by Elsevier in Food Chemistry
- Vol. 495 (Pt 3) , 146578
Quantitative determination of salbutamol residues using a fluorescence immunochromatography assay
- 29 September 2025
- Published by Springer Nature in Journal of Fluorescence
- Vol. 36 (1) , 159-167
Development and Validation of a Multiplex Fluorescent Immunochromatographic Strip for Simultaneous Quantification of MMP-9, LP-PLA2,and hs-CRP
Elevated levels of serum matrix metalloproteinase-9 (MMP-9), lipoprotein-associated phospholipase A2 (LP-PLA2), and high-sensitivity C-reactive protein (hs-CRP) have been shown to be closely associated with the onset and progression of numerous diseases. In light of this, the present study was designed to establish a multiplex fluorescence immunochromatography (FIC) method for the quantitative measurement of MMP-9, LP-PLA2, and hs-CRP in serum. The FIC methods using europium (III) (Eu3+) fluorescent microspheres for quantifying MMP-9, LP-PLA2, and hs-CRP were individually optimized and established. Subsequently, the multiplex FIC test strips (FICTS) were assembled and evaluated. The sensitivity of the multiplex FICTS for detecting MMP-9 was 0.24 ng/mL, for LP-PLA2 it was 0.17 ng/mL, and for hs-CRP it was 0.19 ng/mL. The cross-reactivity with nine potential interferents was consistently low, all below 3.00%. The average recovery rates ranged from 101.62% to 105.55%, with all coefficients of variation being less than 5%. The clinical sensitivity and specificity for all three analytes exceeded 93%. Moreover, a strong Pearson correlation was observed between the results obtained using the multiplex FICTS and those from commercial kits (Pearson r: 0.9246, 0.9009, 0.9697, respectively). The multiplex FICTS that we have designed holds great promise for point-of-care quantitative measurement of MMP-9, LP-PLA2, and hs-CRP. By enabling rapid and accurate on-site detection of these biomarkers, it provides a convenient and efficient alternative to traditional laboratory-based testing methods. This innovative approach has the potential to revolutionize the screening process for diabetic retinopathy.
- 29 September 2025
- Published by Springer Nature in Journal of Fluorescence
- Vol. 36 (1) , 159-167
Development and Validation of a Multiplex Fluorescent Immunochromatographic Strip for Simultaneous Quantification of MMP-9, LP-PLA2,and hs-CRP
Elevated levels of serum matrix metalloproteinase-9 (MMP-9), lipoprotein-associated phospholipase A2 (LP-PLA2), and high-sensitivity C-reactive protein (hs-CRP) have been shown to be closely associated with the onset and progression of numerous diseases. In light of this, the present study was designed to establish a multiplex fluorescence immunochromatography (FIC) method for the quantitative measurement of MMP-9, LP-PLA2, and hs-CRP in serum. The FIC methods using europium (III) (Eu3+) fluorescent microspheres for quantifying MMP-9, LP-PLA2, and hs-CRP were individually optimized and established. Subsequently, the multiplex FIC test strips (FICTS) were assembled and evaluated. The sensitivity of the multiplex FICTS for detecting MMP-9 was 0.24 ng/mL, for LP-PLA2 it was 0.17 ng/mL, and for hs-CRP it was 0.19 ng/mL. The cross-reactivity with nine potential interferents was consistently low, all below 3.00%. The average recovery rates ranged from 101.62% to 105.55%, with all coefficients of variation being less than 5%. The clinical sensitivity and specificity for all three analytes exceeded 93%. Moreover, a strong Pearson correlation was observed between the results obtained using the multiplex FICTS and those from commercial kits (Pearson r: 0.9246, 0.9009, 0.9697, respectively). The multiplex FICTS that we have designed holds great promise for point-of-care quantitative measurement of MMP-9, LP-PLA2, and hs-CRP. By enabling rapid and accurate on-site detection of these biomarkers, it provides a convenient and efficient alternative to traditional laboratory-based testing methods. This innovative approach has the potential to revolutionize the screening process for diabetic retinopathy.
- 22 August 2025
- Published by Springer Nature in Journal of Fluorescence
- Vol. 35 (12) , 12899-12906
A Novel Time-resolved Fluorescence Immunochromatographic Strip for the Diagnosis of Avian Infectious Bronchitis Virus
Avian infectious bronchitis virus (AIBV) is the main pathogen of avian infectious bronchitis (AIB), causing significant economic losses in the poultry industry worldwide. A novel time-resolved fluorescence immunochromatographic (TRFIM) strip for the diagnosis of AIB was developed via sensitive and quantitative detection of AIBV antigen. In this study, a two-steps TRFIM strip based on europiumion (Eu) fluorescence microspheres was first developed for sensitive and quantitative detection of AIBV antigen. The AIBV-MAb usage, T line MAb concentration, Eu-AIBV-MAb complex usage and reaction time were optimized to improve the detection performance and improve the on-site detection efficiency. Finally, prepared and assembled the strips according to the optimal conditions, and then evaluate their sensitivity, specificity, precision, stability, and real sample detection performance. A two-steps TRFIM strips were prepared and assembled, and their sensitivity was 0.17 ng/mL, with high specificity for AIBV. The reference interval of the TRFIM strips is > 0.42 ng/mL, the recoveries of the intra-batch and inter-batch samples ranged from 88.50 to 97.35%, and all coefficient of variations (CVs) were less than 10%. The period of validity is more than 12 month at room temperature. The performance of the TRFIM strips in real sample detection is comparable to RT-PCR. Therefore, the developed strips have high sensitivity, accuracy, specificity and stability for detection of chicken AIBV antigen, exhibiting potential for broad applications in the on-site surveillance of AIBV in the poultry industry.
- 22 August 2025
- Published by Springer Nature in Journal of Fluorescence
- Vol. 35 (12) , 12899-12906
A Novel Time-resolved Fluorescence Immunochromatographic Strip for the Diagnosis of Avian Infectious Bronchitis Virus
Avian infectious bronchitis virus (AIBV) is the main pathogen of avian infectious bronchitis (AIB), causing significant economic losses in the poultry industry worldwide. A novel time-resolved fluorescence immunochromatographic (TRFIM) strip for the diagnosis of AIB was developed via sensitive and quantitative detection of AIBV antigen. In this study, a two-steps TRFIM strip based on europiumion (Eu) fluorescence microspheres was first developed for sensitive and quantitative detection of AIBV antigen. The AIBV-MAb usage, T line MAb concentration, Eu-AIBV-MAb complex usage and reaction time were optimized to improve the detection performance and improve the on-site detection efficiency. Finally, prepared and assembled the strips according to the optimal conditions, and then evaluate their sensitivity, specificity, precision, stability, and real sample detection performance. A two-steps TRFIM strips were prepared and assembled, and their sensitivity was 0.17 ng/mL, with high specificity for AIBV. The reference interval of the TRFIM strips is > 0.42 ng/mL, the recoveries of the intra-batch and inter-batch samples ranged from 88.50 to 97.35%, and all coefficient of variations (CVs) were less than 10%. The period of validity is more than 12 month at room temperature. The performance of the TRFIM strips in real sample detection is comparable to RT-PCR. Therefore, the developed strips have high sensitivity, accuracy, specificity and stability for detection of chicken AIBV antigen, exhibiting potential for broad applications in the on-site surveillance of AIBV in the poultry industry.