Maressa E. Kennedy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maressa E. Kennedy has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Ani E. Smith
Department of Biological Sciences Northern Arizona University Flagstaff Arizona USA
4 shared publications - Christopher J. Mayerl
Department of Biological Sciences Northern Arizona University Flagstaff Arizona USA
4 shared publications - Elska B. Kaczmarek
Department of Biological Sciences Northern Arizona University Flagstaff Arizona USA
4 shared publications - Thomas H. Stroud
Department of Biological Sciences Northern Arizona University Flagstaff Arizona USA
4 shared publications - Dylan J. Anderson
Department of Biological Sciences Northern Arizona University Flagstaff Arizona USA
3 shared publications Emily C. Volpe
Department of Biological Sciences Northern Arizona University Flagstaff Arizona USA
2 shared publications
Latest Publications
- Open Access
- 3 September 2026
- Published by Wiley in The Anatomical Record
A biomimetic ducted nipple reveals gestational age‐dependent deficits in suction generation in a neonatal pig model
All infant mammals must suckle in order to effectively acquire milk from a nipple. Yet, not all infants are able to do so. Preterm infants in particular face significant feeding challenges, often failing to establish successful breastfeeding due to complex neurophysiologic challenges. Unlike the cisternic structure of conventional commercial bottle nipples, often modeled after ruminant anatomy, human and porcine maternal nipples are ducted structures that require intraoral suction for milk release. To investigate how this structural difference impacts feeding success across gestational age, we used a validated infant pig model and high‐speed biplanar fluoroscopy (100 fps), synchronized with intraoral pressure recordings to compare suckling mechanics between term and preterm neonates feeding on either a cisternic or a suction‐dependent ducted (biomimetic) nipple. We found a profound gestational‐age‐dependent divergence in performance. The ducted nipple was successful for term infants because it paralleled natural breastfeeding and replicated its biomechanics by reducing the ability to express milk, thereby enhancing suction generation. While both term and preterm infants positioned the ducted nipple further into the mouth, preterm infants failed to adjust their tongue kinematics to compensate for this change. This inability led to minimal suction generation and poor milk acquisition. The lack of kinematic compensation in preterm infants isolates a critical physiological adaptability deficit, stemming from both neurological (lack of flexible seal adjustment/disordered coordination of the suck‐swallow‐breathe sequence) and anatomical constraints related to an inadequate seal on the nipple. Future research must explore these deficits' interactions to understand suckling physiology and develop targeted interventions for this population.
- 3 September 2026
- Published by Wiley in The Anatomical Record
Open AccessA biomimetic ducted nipple reveals gestational age‐dependent deficits in suction generation in a neonatal pig model
All infant mammals must suckle in order to effectively acquire milk from a nipple. Yet, not all infants are able to do so. Preterm infants in particular face significant feeding challenges, often failing to establish successful breastfeeding due to complex neurophysiologic challenges. Unlike the cisternic structure of conventional commercial bottle nipples, often modeled after ruminant anatomy, human and porcine maternal nipples are ducted structures that require intraoral suction for milk release. To investigate how this structural difference impacts feeding success across gestational age, we used a validated infant pig model and high‐speed biplanar fluoroscopy (100 fps), synchronized with intraoral pressure recordings to compare suckling mechanics between term and preterm neonates feeding on either a cisternic or a suction‐dependent ducted (biomimetic) nipple. We found a profound gestational‐age‐dependent divergence in performance. The ducted nipple was successful for term infants because it paralleled natural breastfeeding and replicated its biomechanics by reducing the ability to express milk, thereby enhancing suction generation. While both term and preterm infants positioned the ducted nipple further into the mouth, preterm infants failed to adjust their tongue kinematics to compensate for this change. This inability led to minimal suction generation and poor milk acquisition. The lack of kinematic compensation in preterm infants isolates a critical physiological adaptability deficit, stemming from both neurological (lack of flexible seal adjustment/disordered coordination of the suck‐swallow‐breathe sequence) and anatomical constraints related to an inadequate seal on the nipple. Future research must explore these deficits' interactions to understand suckling physiology and develop targeted interventions for this population.
- 1 September 2025
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 139 (3) , 719-730
Infant pigs demonstrate motor adaptation across multiple physiologic functions during feeding in response to dynamic changes in milk flow rate
We developed a novel method to dynamically alter milk flow rate mid-feed in infant pigs to assess real-time neurophysiological responses. Unlike prior studies, our approach avoids confounding variables that would result from providing nipples of different flow rates during separate feeding sessions and reveals how motor output adapts to sensory input in real time, offering new insight into the neuromotor control underlying infant feeding.
- 1 September 2025
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 139 (3) , 719-730
Infant pigs demonstrate motor adaptation across multiple physiologic functions during feeding in response to dynamic changes in milk flow rate
We developed a novel method to dynamically alter milk flow rate mid-feed in infant pigs to assess real-time neurophysiological responses. Unlike prior studies, our approach avoids confounding variables that would result from providing nipples of different flow rates during separate feeding sessions and reveals how motor output adapts to sensory input in real time, offering new insight into the neuromotor control underlying infant feeding.
- 22 August 2025
- Published by Springer Nature in Pediatric Research
- Vol. 99 (3) , 1212-1221
A ducted, biomimetic nipple replicates breastfeeding mechanics through ontogeny in an infant animal model
Background Although there are known physiological and developmental benefits for breastfed infants, many infants must be bottle-fed for a variety of reasons. We hypothesize that some of these health disparities are caused by biomechanical differences in milk acquisition between breastfeeding and bottle feeding (suction versus expression) that are caused by fundamental structural differences between breast tissue (which has narrow ducts) and bottle nipples (which are hollow). Methods To evaluate if a biomimetic, ducted bottle nipple elicits suckling physiology that is more similar to breastfeeding than conventional bottle feeding, we studied suckling in full-term infant pigs, a validated animal model for infant feeding. We raised one group on each nipple type and fed all pigs from both nipple types at the end of infancy. We recorded synchronous videofluoroscopy and intraoral suction and calculated the rate of milk consumption. Results Infants raised on ducted nipples generated greater intraoral suction throughout most of infancy. In contrast, infants raised on cisternic nipples compressed the nipples more, swallowed larger boluses, and consumed milk at a faster rate. Conclusions These differences mirror those reported between breastfeeding and bottle feeding, suggesting that a biomimetic nipple elicits mechanics that are similar to breastfeeding and can improve feeding outcomes. Impact Milk acquisition from ducted, biomimetic bottle nipples mirrored the mechanics of breastfeeding by eliciting greater suction generation, reduced nipple compression, and a slower rate of milk consumption compared to feeding from cisternic nipples. Differences in the physiology and mechanics of milk acquisition between breastfeeding and bottle feeding can be attributed to the structural differences between ducted breast tissue and hollow bottle nipples. The use of ducted bottle nipples has the potential to reduce disparities in physiological and developmental health outcomes between breastfed and bottle-fed infants and improve the ability for caretakers to transition between breast and bottles for feeding.
- 22 August 2025
- Published by Springer Nature in Pediatric Research
- Vol. 99 (3) , 1212-1221
A ducted, biomimetic nipple replicates breastfeeding mechanics through ontogeny in an infant animal model
Background Although there are known physiological and developmental benefits for breastfed infants, many infants must be bottle-fed for a variety of reasons. We hypothesize that some of these health disparities are caused by biomechanical differences in milk acquisition between breastfeeding and bottle feeding (suction versus expression) that are caused by fundamental structural differences between breast tissue (which has narrow ducts) and bottle nipples (which are hollow). Methods To evaluate if a biomimetic, ducted bottle nipple elicits suckling physiology that is more similar to breastfeeding than conventional bottle feeding, we studied suckling in full-term infant pigs, a validated animal model for infant feeding. We raised one group on each nipple type and fed all pigs from both nipple types at the end of infancy. We recorded synchronous videofluoroscopy and intraoral suction and calculated the rate of milk consumption. Results Infants raised on ducted nipples generated greater intraoral suction throughout most of infancy. In contrast, infants raised on cisternic nipples compressed the nipples more, swallowed larger boluses, and consumed milk at a faster rate. Conclusions These differences mirror those reported between breastfeeding and bottle feeding, suggesting that a biomimetic nipple elicits mechanics that are similar to breastfeeding and can improve feeding outcomes. Impact Milk acquisition from ducted, biomimetic bottle nipples mirrored the mechanics of breastfeeding by eliciting greater suction generation, reduced nipple compression, and a slower rate of milk consumption compared to feeding from cisternic nipples. Differences in the physiology and mechanics of milk acquisition between breastfeeding and bottle feeding can be attributed to the structural differences between ducted breast tissue and hollow bottle nipples. The use of ducted bottle nipples has the potential to reduce disparities in physiological and developmental health outcomes between breastfed and bottle-fed infants and improve the ability for caretakers to transition between breast and bottles for feeding.
- 12 July 2025
- Published by Oxford University Press (OUP) in Integrative and Comparative Biology
- Vol. 65 (6) , 1498-1511
Evaluating the Impact of Nipple Design on Tongue Function in Infant Feeding Using a Dynamic Endocast
Synopsis: The mammalian tongue is a muscular hydrostat composed of multiple muscles, each with complex fiber architecture and small motor units. This allows it to move and deform in three dimensions (3D) to function in several complex behaviors, including suckling. The ability of infant mammals to successfully suckle is dependent on these variable deformations, as the tongue must perform multiple functions simultaneously. The lateral margins of the tongue curl to seal around a nipple, while the middle of the tongue moves in an anteroposterior wave to suck milk into the mouth, transport it posteriorly, and swallow it. The kinematics, mechanics, and coordination of the tongue during suckling are impacted by nipple properties, as evidenced by differences between feeding from nipples with narrow ducts (e.g., breastfeeding) and nipples that are hollow cisterns (e.g., bottle feeding). These structural differences result in different feeding outcomes, yet their effect on tongue function and kinematics is poorly understood. In addition, despite the 3D shape of the tongue during suckling, measurements of tongue movement have been limited to motion along the midsagittal plane and have not assessed suck volume. To evaluate how tongue function differs between ducted and cisternic nipples, we used X-ray Reconstruction of Moving Morphology and a dynamic endocast, synchronized with intraoral suction, to quantify 3D tongue kinematics and suck volume. We found that pigs generated less suction but had greater suck volumes when they fed on cisternic nipples compared to ducted nipples. This is likely because the pigs compressed the cisternic nipple to express milk, resulting in higher flow, which we hypothesize slowed the accumulation of suction and permitted the tongue to achieve a larger suck volume. These results suggest that nipple design impacts the relationship between fluid dynamics and tongue function during feeding. In addition, we found that infants moved the surface of their tongue ventrally and posteriorly throughout the suck, but they did not increase the width of the suck volume. The use of a digital endocast to measure suck volume represents an important advance in our ability to evaluate the mechanics of feeding and could be used in the future to understand the relationships between tongue function and performance as infants mature, as well as in a comparative framework.
- 12 July 2025
- Published by Oxford University Press (OUP) in Integrative and Comparative Biology
- Vol. 65 (6) , 1498-1511
Evaluating the Impact of Nipple Design on Tongue Function in Infant Feeding Using a Dynamic Endocast
Synopsis: The mammalian tongue is a muscular hydrostat composed of multiple muscles, each with complex fiber architecture and small motor units. This allows it to move and deform in three dimensions (3D) to function in several complex behaviors, including suckling. The ability of infant mammals to successfully suckle is dependent on these variable deformations, as the tongue must perform multiple functions simultaneously. The lateral margins of the tongue curl to seal around a nipple, while the middle of the tongue moves in an anteroposterior wave to suck milk into the mouth, transport it posteriorly, and swallow it. The kinematics, mechanics, and coordination of the tongue during suckling are impacted by nipple properties, as evidenced by differences between feeding from nipples with narrow ducts (e.g., breastfeeding) and nipples that are hollow cisterns (e.g., bottle feeding). These structural differences result in different feeding outcomes, yet their effect on tongue function and kinematics is poorly understood. In addition, despite the 3D shape of the tongue during suckling, measurements of tongue movement have been limited to motion along the midsagittal plane and have not assessed suck volume. To evaluate how tongue function differs between ducted and cisternic nipples, we used X-ray Reconstruction of Moving Morphology and a dynamic endocast, synchronized with intraoral suction, to quantify 3D tongue kinematics and suck volume. We found that pigs generated less suction but had greater suck volumes when they fed on cisternic nipples compared to ducted nipples. This is likely because the pigs compressed the cisternic nipple to express milk, resulting in higher flow, which we hypothesize slowed the accumulation of suction and permitted the tongue to achieve a larger suck volume. These results suggest that nipple design impacts the relationship between fluid dynamics and tongue function during feeding. In addition, we found that infants moved the surface of their tongue ventrally and posteriorly throughout the suck, but they did not increase the width of the suck volume. The use of a digital endocast to measure suck volume represents an important advance in our ability to evaluate the mechanics of feeding and could be used in the future to understand the relationships between tongue function and performance as infants mature, as well as in a comparative framework.