Aleesa Mardirossian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aleesa Mardirossian has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Brett Andrew Dolezal
Airway and UC Fit Digital Health-Exercise Physiology Laboratory, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA 90024, USA
1 shared publication - Dylan Cho
University of California, Los Angeles
1 shared publication - Eric V. Neufeld
Northwell New Hyde Park New York U.S.A.
1 shared publication - Jacob J. Bright
University of California, Los Angeles
1 shared publication - Trent Yamamoto
Airway and UC Fit Digital Health-Exercise Physiology Laboratory, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA 90024, USA
1 shared publication
Latest Publications
- Open Access
- 23 August 2025
- Published by Asociacion Espanola de Analisis del Rendimiento Deportivo in Scientific Journal of Sport and Performance
- Vol. 4 (4) , 612-622
Accuracy of body fat percentage measurements from a smartphone-based 3D application compared to a bioelectrical impedance analyser
Conventional methods of assessing body composition are accurate but may not be accessible beyond clinical settings. While technological advances have led to the development of more convenient alternative measures, their accuracy has yet to be determined. The present investigation assessed the accuracy of a smartphone-based 3D application’s measurements of body fat percentage in comparison to a bioelectrical impedance analyser (BIA), a well-established criterion measure. Sixty-nine apparently healthy, college-aged adults had their body fat percentage measured with BIA followed by the smartphone-based application. Spearman’s rank correlation was calculated to be 0.98 (95% CI: 0.92, 0.99), indicating a very strong correlation between the two BF percentage measures. The bias observed between the two devices was low (0.2% [95% CI: -0.1, 0.5]) with limits of agreement spanning from -2.9% (95% CI: -3.4, -2.3) to 3.2% (95% CI: 2.7, 3.8). Given the strong overall agreement between the two modalities, this smartphone-based application may have the potential to make accurate body fat measurements more accessible. Further validation is needed in more diverse populations and against other criterion measures, such as dual-energy x-ray absorptiometry (DXA).
- 23 August 2025
- Published by Asociacion Espanola de Analisis del Rendimiento Deportivo in Scientific Journal of Sport and Performance
- Vol. 4 (4) , 612-622
Open AccessAccuracy of body fat percentage measurements from a smartphone-based 3D application compared to a bioelectrical impedance analyser
Conventional methods of assessing body composition are accurate but may not be accessible beyond clinical settings. While technological advances have led to the development of more convenient alternative measures, their accuracy has yet to be determined. The present investigation assessed the accuracy of a smartphone-based 3D application’s measurements of body fat percentage in comparison to a bioelectrical impedance analyser (BIA), a well-established criterion measure. Sixty-nine apparently healthy, college-aged adults had their body fat percentage measured with BIA followed by the smartphone-based application. Spearman’s rank correlation was calculated to be 0.98 (95% CI: 0.92, 0.99), indicating a very strong correlation between the two BF percentage measures. The bias observed between the two devices was low (0.2% [95% CI: -0.1, 0.5]) with limits of agreement spanning from -2.9% (95% CI: -3.4, -2.3) to 3.2% (95% CI: 2.7, 3.8). Given the strong overall agreement between the two modalities, this smartphone-based application may have the potential to make accurate body fat measurements more accessible. Further validation is needed in more diverse populations and against other criterion measures, such as dual-energy x-ray absorptiometry (DXA).