KKKathrin Korff

Kathrin Korff

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kathrin Korff has a total of 57 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    In situ polymerized monolith tips for reproducible, format-flexible proteomic sample preparation applied to biofluids

    by Kathrin Korff, Lukas T. Henneberg, Denys Oliinyk, Nils Eikmeier, Anton M. Schüle, Tim Heymann, Alicia-Sophie Schebesta, Vincent Albrecht, Michael Roehrl, Christoph J.O. Kaiser, et al.

  • Open Access

    FastaLake selects compact metaproteomic databases from large sequence reservoirs by de novo peptide lookup

    by Peter V. Treit, Florian A. Rosenberger, Philip Hartout, Mikhail Lebedev, Jinqiu Xiao, Maximilian Zwiebel, Philipp E. Geyer, Ankit Sinha, Georg Wallmann, Vincenth Brennsteiner, et al.

    Metaproteomics analyses require protein sequence databases, yet the microbial proteins present in complex communities are not known in advance. Searching reference catalogs containing hundreds of millions of candidate sequences reduces identification sensitivity, while generating sample-specific databases through metagenomic sequencing adds time and cost. We introduce FastaLake, a computational workflow that uses full-length de novo peptide predictions by AlphaNovo to retrieve complete proteins from broad sequence resources and selects compact databases for conventional searching. In a defined eight-member community, FastaLake approached reference-search peptide yields without knowing its members. Using public sequence catalogs, FastaLake identified about as many peptides as matched metagenomic databases in two stool cohorts and 20–35% more in intestinal fluid at the same nominal 1% peptide false discovery rate. The resulting proteomes reveal personal functional profiles that persist across intestinal regions despite differences in leading species between intestinal fluid and stool. DNA, RNA and protein profiles agreed on broad differences between patients but only weakly on individual functions. All 726 acquisition-specific databases were smaller than the human reference proteome. Compact databases allowed non-specific searches of all 347 CapScan acquisitions, revealing histidine enrichment at peptide C termini in intestinal fluid. FastaLake enables metaproteomics analysis without matched metagenomic sequencing by constructing search databases from sequence resources and de novo peptide sequencing.

  • Open Access

    Differentiating benign from malignant adnexal masses by biomarker-agnostic plasma proteomics using adaptive machine learning

    by Johannes B. Müller-Reif, Sarah Ackroyd, Vincent Albrecht, Melanie Weigert, Kathrin Korff, Alicia-Sophie Schebesta, Roni Yoeli-Bik, Maryam Siddiqui, Andrew Rausch, Emese Zsiros, et al.

    Summary: Background: Pre-operative triage of adnexal masses with serum CA-125, HE4, and ultrasound (O-RADS) has limited accuracy, contributing to unnecessary surgery. We develop and validate a first of its kind, biomarker panel-free plasma proteomic classifier that distinguishes malignant from benign adnexal masses from a single blood draw, operating directly on discovery-mode mass spectrometry. Methods: In this multicenter prospective observational study, plasma from women with adnexal masses and from healthy controls at a large urban academic center (discovery and four validation cohorts) and an external academic center from another Urban-suburban area (external validation) was analyzed by data-independent-acquisition mass spectrometry (Orbitrap Astral), quantifying >1,000 proteins per sample. Cancerous (malignant, borderline adnexal mass, or metastasis to ovary) versus benign adnexal masses were classified with ADAPT-MS (Adaptive Diagnostic Architecture for Personalized Testing by Mass Spectrometry), which retrains an ElasticNet model for each sample based on the proteins measured. The primary outcome was discrimination (area under the receiver operating characteristic curve [AUC]). Pre-operative O-RADS scores and serum CA-125 were compared and combined with proteomics on matched subsets. Findings: Using a discovery cohort (n=1062), an ADAPT-MS classifier, validated across five independent cohorts (n=623), achieved a summary AUC of 0.835 (cohort range 0.779–0.904). Among patients with pre-operative O-RADS (n=231), proteomics (AUC 0.852) was comparable to O-RADS alone (0.863) and combining them raised discrimination to 0.922. Proteomics outperformed serum CA-125 (0.915 versus 0.777; n=125) and proteome-derived ROMA-like and two-marker surrogates. Biologically, the classification-relevant proteins are enriched for host response proteins rather than tumor cell associated protein changes, comprising ECM remodeling, complement and innate immune response pathways. This explains good detection of tumor with heterogenous pathology and also metastasis to ovary. Interpretation: A single plasma proteomic measurement interpreted using adaptive machine learning discriminates malignant from benign adnexal masses with good internal and external validation, and is complementary to ultrasound, warranting prospective evaluation as a panel-free diagnostic adjunct to imaging. Funding: Funded by the Max Planck Society for the Advancement of Sciences (MM), an NIH R35 grant (EL), and support from Arthur and Nicole Herbst (EL). Research in context: Evidence before this study: Presence of protein biomarkers for ovarian cancer and in detail, adnexal mass triage is historically present e.g. by CA-125 or HE4. Proteomics studies have shown many more potential protein markers that might be used as biomarkers instead or additional to the presently used ones. Classification algorithms however do currently rely on single or few biomarkers only, limiting sensitivity and specificity. Added value of this study: To our knowledge, this study is the first example of a proteomics classifier that uses ML on discovery-based MS-proteomics data at the single-sample level and thus has the potential for diagnostic use. While in the past, proteomics has been used as a discovery tool and potential markers needed to be subjected to a follow-up assay development, we show by application to 5 different independent validation cohorts that a proteomics classifier based on the recently developed architecture Adaptive Diagnostic Architecture for Personalized Testing by Mass Spectrometry (ADAPT-MS) generalizes in performance between discovery and validation cohorts and can be applied at the single sample level. Implications of all the available evidence: We demonstrate that proteomics can be applied beyond discovery and classify adnexal masses together with ultrasound at an AUC of 0.922. This sets a precedence case for other diagnostic applications of proteomics, both in study design (plasma proteomics is always measured and used to best of ability in discovery and validation), and in single-sample application mode by ADAPT-MS.

  • Open Access

    Limited impact of column chemistry and length on proteome coverage under high-speed DIA

    by Alicia-Sophie Schebesta, Kathrin Korff, Ericka C.M. Itang, Vincent Albrecht, Philipp E. Geyer, Johannes B. Mueller-Reif

  • Open Access

    In situ polymerized monolith tips for reproducible, format-flexible proteomic sample preparation applied to biofluids

    by Kathrin Korff, Lukas Henneberg, Denys Oliinyk, Nils Eikmeier, Anton M. Schuele, Tim Heymann, Alicia-Sophie Schebesta, Vincent Albrecht, Christoph J.O. Kaiser, Matthias Mann, et al.

    Sample preparation increasingly sets the throughput and reproducibility of mass spectrometry (MS)-based proteomics. StageTips (stop-and-go extraction tips) and variants thereof have long been common implements to purify samples, and we recently extended the concept to solid-phase extraction capture (SPEC) tips, in which the entire digestion takes place in sub-microliter volumes. Here we replace the hand-packed bed with a strong anion-exchange (SAX) monolith photopolymerized directly inside the pipette tip from a defined recipe (pSPEC). A liquid-handling robot casts 384 tunable tips in minutes, at low cost and in any format, adding negligibly to the workflow's variance. Across biofluids, pSPEC added ~20% more identifications than in-solution plasma and reached 3,500 protein groups from a single injection of healthy urine and 4,800 from saliva at 100 samples per day, depths usually requiring depletion or fractionation. The same light-cast chemistry should extend to single cells, affinity capture, and population-scale studies.

  • Deeper is not always better in plasma proteomics

    by Huanhuan Gao, Kathrin Korff, Matthias Mann, Tiannan Guo


  • Open Access

    Pre-analytical drivers of bias in bead-enriched plasma proteomics

    by Kathrin Korff, Johannes B Müller-Reif, Dorothea Fichtl, Vincent Albrecht, Alicia-Sophie Schebesta, Ericka C M Itang, Sebastian Virreira Winter, Lesca M Holdt, Daniel Teupser, Matthias Mann, et al.

    Bead-based enrichment is a promising strategy to improve depth in plasma proteomics by overcoming the dynamic range barrier. However, its robustness against pre-analytical variation has not been sufficiently characterized. Here, we systematically evaluate five plasma proteomics workflows, including three bead-based methods, a neat workflow, and a precipitation protocol using spike-ins of low-abundance proteins and defined cellular contaminants. We find that bead-based approaches enhance detection of low-abundance proteins but can be highly susceptible to systematic bias from platelet and PBMC contamination. This can inflate results by thousands of proteins, potentially explaining some of the high literature-reported numbers. A perchloric acid-based workflow shows resistance to erythrocyte and platelet-derived contamination. We investigate how centrifugation conditions, anticoagulant choice, and buffer-bead combinations modulate contamination profiles and demonstrate that bias can be mitigated by optimized sample handling. Altogether, we identify more than 13,000 different protein groups, including cellular components from the circulating proteome. Our results provide a quantitative framework for assessing workflow performance under variable sample quality and offer guidance for both biomarker discovery and quality control in clinical proteomics studies.


  • Open Access

    Exploring chromatographic dimensions for state-of-the-art proteomics applications

    by Alicia-Sophie Schebesta, Kathrin Korff, Ericka C.M. Itang, Vincent Albrecht, Philipp E. Geyer, Johannes B. Mueller-Reif

    The evolution of mass spectrometry (MS)-based proteomics has been driven by continuous technological advances in sample preparation, instrumentation, and data acquisition. While chromatographic separation has historically been considered a critical bottleneck in achieving comprehensive proteome coverage, recent developments in ultra-fast data acquisition fundamentally challenge this paradigm. We investigated whether the traditional paradigm that chromatographic performance directly correlates with proteome depth still holds true. Spanning a matrix of experiments with five distinct stationary phases, including C18 chemistries, C8, and Phenyl-Hexyl, across eight column lengths (40-140 mm), we evaluate protein identification performance using data-independent acquisition (DIA) on the Orbitrap Astral mass spectrometer. Despite substantial chromatographic differences, we observed remarkably convergent proteome coverage metrics. All C18 and C8 phases consistently achieved over 150,000 precursor- and approximately 9,000 protein group identifications, regardless of column length variations. While distinct selectivity fingerprints persisted across chemistries, these chromatographic differences did not translate into meaningful variations in proteome coverage under high-speed acquisition conditions at 200 Hz. We conclude that the analytical bottleneck has fundamentally shifted from chromatographic resolution to mass spectrometric sampling efficiency, where comprehensive peptide identification is now gained through advanced spectral deconvolution rather than physical separation alone. This paradigmatic shift is reflected in modern proteomics by method development priorities being directed beyond traditional separation optimization, with greater emphasis placed on operational robustness, analytical throughput, and reproducibility.