AMAlexandre Meynard

Alexandre Meynard

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alexandre Meynard has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • Benjamin Pommier

    Spine Surgery Unit, Hôpital Neurologique Pierre Wertheimer, Hospices Civils de Lyon, and University Claude Bernard of Lyon 1, Bron, France

    1 shared publication
  • Bertrand Fréchède

    LBMC UMR T 9406, Univ Lyon, Univ Claude Bernard Lyon 1, Univ Gustave Eiffel, Lyon, France

    1 shared publication
  • Cyrille B. Confavreux

    Département de Rhumatologie Sud, Centre Expert Des Métastases Osseuses (CEMOS), Institut de Cancérologie Des Hospices Civils de Lyon, Hôpital Lyon Sud, Pierre-Bénite, France

    1 shared publication
  • Cédric Barrey

    Spine Surgery Unit, Hôpital Neurologique Pierre Wertheimer, Hospices Civils de Lyon, and University Claude Bernard of Lyon 1, Bron, France

    1 shared publication
  • Cédric Barrey

    Department of Spine and Spinal Cord Surgery, P. Wertheimer Hospital, Hospices Civils de Lyon, Lyon, France; Univ Gustave Eiffel, Université Lyon 1, LBMC UMR_T9406, Lyon, France

    1 shared publication
  • David Mitton

    LBMC UMR T 9406, Univ Lyon, Univ Claude Bernard Lyon 1, Univ Gustave Eiffel, Lyon, France

    1 shared publication

Latest Publications

  • Predicting mechanical failure in spinal metastases: from clinical scores to patient-specific biomechanical modeling

    by Louis Anzalone, Hélène Follet, Alexandre Meynard, Cyrille Confavreux, Maria-Rossella Fasinella, Evelyne Emery, David Mitton, Cédric Y. Barrey

  • Biomechanical Comparison of Facet Versus Laminar C2 Screws

    by Alexandre Meynard, Bertrand Fréchède, Benjamin Pommier, David Mitton, Cédric Barrey

    BACKGROUND: Transpedicular or transisthmic screws for C2 instrumentation represent the gold standard; however, the anatomy is not always compatible (hypoplastic pedicles, procidentia of the vertebral artery). Laminar screws (LS) have been proposed as a rescue technique and recently, bicortical facet screws (FS). To date, the biomechanical property of FS remains unknown. OBJECTIVE: To compare the pull-out resistance of bicortical facet (FS) vs laminar (LS) C2 screws. METHODS: Thirty-two human cadaveric C2 vertebrae were screened by CT scan imaging and dual x-ray absorptiometry before receiving both techniques and were randomized according to side and sequence (FS or LS first). Screw positioning was validated using 2-dimensional x-rays. Sixty-four mechanical tests were performed using pure tensile loading along the axis of the screws until pull-out. Mean pull-out strengths were compared using paired tests, multivariate and survival analysis (Kaplan-Meier curves). RESULTS: The morphometric data were consistent with previous studies. Over 64 tests, the mean pull-out strength of LS (707 ± 467 N) was significantly higher than that of FS (390 ± 230 N) (P = .0004). Bone mineral density was weakly correlated with pull-out strength (r = 0.42 for FS and r = 0.3 for LS). Both techniques were mechanically equivalent for vertebrae in which intralaminar cortical grip was not achievable for LS. The mean pull-out strength for LS with laminar cortical grip (1071 ± 395 N) was significantly higher than that of LS without (423 ± 291 N) (P < .0001). CONCLUSION: Our results suggest that bicortical FS of C2 offer less mechanical resistance than LS.