ZQZheng Qiu

Zheng Qiu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zheng Qiu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Research on Temperature Distribution Reconstruction of Deflagration Fields via Spectral-Image Fusion

    by Meng Zhao, Maoyong Bai, Zhaojun Wu, Shaodong Bai, Zheng Qiu, Kang Du, Yong Tan, Hongxing Cai

    Multispectral temperature measurement technology based on blackbody radiation theory has been widely applied in the field of non-contact temperature measurement. However, its applicability is limited by the single-point measurement mode. To address this limitation, this study developed a spectral fusion temperature measurement device and proposed a new method for reconstructing the two-dimensional temperature field of deflagration fireballs by fusing spectral and imaging data. The device adopts a CCD sensor and a fiber optic spectrometer placed in parallel with parallel optical axes. To ensure the accuracy of the CCD’s response characteristics at different distances, the photo-response non-uniformity (PRNU) calculation method was used for precision validation. In this study, spectral and imaging data of deflagration fireballs were obtained through experiments. Spectral data of consecutive frames at 189 ms, 192 ms, 195 ms, and 198 ms were extracted and analyzed, confirming that the temperature range at the four time points is 1050 K to 1800 K. The proposed method generates temperature elements with equal temperature intervals and their probabilities within the temperature range, and calculates the theoretical radiation spectrum of each element. Then, least squares optimization fitting is performed on the experimentally measured spectra to obtain the optimal probabilities of the temperature elements in the temperature field. By combining these optimal probabilities with CCD grayscale images, the 2D temperature distribution of the deflagration fireball was reconstructed. Results show that: the PRNU value of the device at a distance of 9 m is less than 2.2% through experimental verification; fused images of the temperature field spectra of four consecutive frames of the deflagration fireball were obtained using the proposed method. The average temperatures reconstructed by the proposed method at 189 ms, 192 ms, 195 ms, and 198 ms were 1382 K, 1373 K, 1366 K, and 1357 K, respectively, while the corresponding temperatures obtained by conventional spectral inversion were 1430 K, 1422 K, 1414 K, and 1406 K. The relative errors were 3.2%, 3.4%, 3.3%, and 3.4%, respectively, with an average relative error of approximately 3.3%.


  • Open Access

    Analysis of the Impact of Multi-Angle Polarization Bidirectional Reflectance Distribution Function Angle Errors on Polarimetric Parameter Fusion

    by Zhong Lv, Zheng Qiu, Hengyi Sun, Jianwei Zhou, Jianbo Wang, Feng Chen, Haoyang Wu, Zhicheng Qin, Zhe Wang, Jingran Zhong, et al.

    This study developed an inertial measurement unit (IMU)-enhanced bidirectional reflectance distribution function (BRDF) imaging system to address angular errors in multi-angle polarimetric measurements. The system integrates IMU-based closed-loop feedback, motorized motion, and image calibration, achieving zenith angle error reduction of up to 1.2° and angular control precision of approximately 0.05°. With a modular and lightweight structure, it supports rapid deployment in field scenarios, while the 2000 mm rail span enables detection of large-scale targets and three-dimensional reconstruction beyond the capability of conventional tabletop devices. Experimental evaluations on six representative materials show that compared with mark-based reference angles, IMU feedback consistently improves polarimetric accuracy. Specifically, the degree of linear polarization (DoLP) mean deviations are reduced by about 5–12%, while standard deviation fluctuations are suppressed by 20–40%, enhancing measurement repeatability. For the angle of polarization (AoP), IMU feedback decreases mean errors by 10–45% and lowers standard deviations by 10–37%, ensuring greater spatial phase continuity even under high-reflection conditions. These results confirm that the proposed system not only eliminates systematic angular errors but also achieves robust stability in global measurements, providing a reliable technical foundation for material characterization, machine vision, and volumetric reconstruction.