SASk Mintajuddin Ahamed

Sk Mintajuddin Ahamed

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sk Mintajuddin Ahamed has a total of 2 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Electroosmotic vortices-mediated active micromixer: Unveiling the performance of mixing quality

    by Sk Mintajuddin Ahamed, Amitava Dutta, Nirmalendu Biswas

    This work presents a micromixer with a diamond-shaped electroosmotic mixing chamber designed to improve fluid mixing at the microscale. The micromixer employs alternating current (AC) electroosmosis, facilitated by symmetrically positioned microelectrodes, which generate vortices that disturb laminar flow and promote enhanced convective mixing. The research examines how different operational parameters, such as average inlet velocity (U0), AC frequency (f), voltage amplitude (V0), and the inclination angle (α = 0°, 20°, 40°, and 60°) of the mixing chamber, affect mixing efficiency. The investigation is carried out systematically to analyze the performance of the mixing chamber at various inclination angles to maximize the mixing quality. A comprehensive numerical investigation is conducted to evaluate the influence of key parameters, including average inlet velocity (U0), AC frequency (f), voltage amplitude (V0), and the inclination angle of the mixing chamber (α). The governing equations for laminar flow, electric currents, and species transport are solved using the finite element-based solver. The results indicate that the diamond-shaped chamber geometry is critical in creating stable, symmetric vortices, which enhance the interaction between the two fluid streams. The optimal mixing performance is achieved at α = 20° with U0 = 0.05 mm/s, V0 = 0.5 V, and f = 8 Hz, reaching a maximum mixing quality of 98.47%, while maintaining a relatively low mixing cost of 0.001 485, under these conditions. Moreover, the study evaluates the relationship between mixing cost, mixing quality, and pressure drop, emphasizing how different inclination angles affect both. Pressure variation along the microchannel is also analyzed for different inclination angles, showing a trade-off between mixing quality and pressure drop. The findings highlight the potential of electrode-driven micromixers in achieving efficient mixing for low-Reynolds-number microfluidic systems, with potential applications in lab-on-a-chip devices and biochemical processes.


  • Optimizing electroosmotic micromixing performance in converging–diverging microchannels: Effect of mixing chamber shape

    by Sk Mintajuddin Ahamed, Amitava Dutta, Nirmalendu Biswas

    Efficient mixing of fluids in microfluidic systems is a challenging task due to the dominance of laminar flow at small scales. This study numerically explores the electroosmotic micromixing in a converging–diverging microchannel using four distinct mixing chamber geometry shapes: straight (MM1), circular (MM2), diamond (MM3), and square (MM4). All designs are free of baffles and utilize electroosmotic flow (EOF) generated by diagonally placed two pairs of microelectrodes to induce efficient mixing. In particular, such design has not been extensively explored in relation to EOF-driven micromixing, and the present study explores new insights into its effectiveness for enhancing mixing and optimizing energy efficiency in microfluidic devices. The transport equations are solved utilizing the finite element method-based computing technique. The parametric simulations explore the effects of average inlet velocity (U0), voltage amplitude (V0), and alternating current (AC) frequency (f) on the mixing performance and pressure drop features. The results revealed that, among all the configurations, the diamond-shaped mixing chamber (MM3) shows the highest mixing quality, reaching 98.95% under optimal operating conditions (U0 = 0.05 mm/s, V0 = 0.5 V, and f = 8 Hz). This geometry facilitated strong, stable vortex generation and improved convective mixing without increasing pressure drop significantly. Additionally, the pressure distribution analysis of MM3 demonstrated that the geometry maintains favorable pressure gradients, promoting efficient recirculation and mixing. This research demonstrates that the mixing chamber geometry, in conjunction with controlled electrokinetic parameters, plays a critical role in mixing enhancement. The diamond shape configuration presents a robust, baffle-free solution for advanced lab-on-a-chip applications requiring high mixing efficiency.