Nishant Kumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Nishant Kumar has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Arun Kumar
Electrical Engineering, Indian Institute of Technology (IIT) Jodhpur, Jodhpur, India
10 shared publications - Rituvic Pandey
Department of Electrical Engineering, Indian Institute of Technology Jodhpur, Jodhpur, India
7 shared publications - Keshav Dutt
Indian Institute of Technology Jodhpur
4 shared publications - Naresh Kumar Kumawat
Electrical Engineering, Indian Institute of Technology Jodhpur, Jodhpur, India
4 shared publications - Shobhit Sharma
Indian Institute of Technology Jodhpur (I.I.T-J), Jodhpur, Rajasthan, India
4 shared publications - Jung-Wook Park
Department of Pathology, Duke University School of Medicine, Durham, NC 27710, USA; Duke Cancer Institute Center for Prostate and Urologic Cancer, Durham, NC 27710, USA
2 shared publications
Latest Publications
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (12) , 21759-21769
Hybrid Digital Twin-Based Health Monitoring and Parameter Estimation of Grid-Tied PV Systems
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (12) , 21759-21769
Hybrid Digital Twin-Based Health Monitoring and Parameter Estimation of Grid-Tied PV Systems
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 72 (4) , 10823-10830
Stealthy False Data Injection Attack Detection via LMI-Optimized Luenberger Observer and Finite-Time Sliding Mode Recovery for Consumer IoT Islanded Microgrid Secondary Control
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 72 (4) , 10823-10830
Stealthy False Data Injection Attack Detection via LMI-Optimized Luenberger Observer and Finite-Time Sliding Mode Recovery for Consumer IoT Islanded Microgrid Secondary Control
- 10 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Reliability
- Vol. 75 (00189529) , 2145-2158
System Modeling-Based Verification of Datasets for Reliable Data-Driven Digital Twin Development in Grid-Connected Solar Photovoltaic Inverter
Ensuring reliable operation of grid-tied photovoltaic (PV) inverters is critical as semiconductor aging, environmental variability, and grid disturbances pose major threats to system stability. This work presents a Data-Driven Digital Twin (DD-DT) framework for real-time predictive monitoring of a two-stage single-phase grid-connected PV inverter, incorporating Physics-Aware Statistical Cross Validation (PASCV) and Temporal Convolutional Networks (TCN). The proposed framework addresses critical challenges such as sensor noise, measurement faults, and system variations by integrating a physics-based validation layer with DD learning. PASCV ensures only trusted measurements are used for model training and real-time synchronization, while TCN enables high-fidelity time-domain prediction of key inverter states under dynamic operating conditions. Experimental validation is carried out on an NIsbRIO-OPAL-RT-based hardware testbed under diverse scenarios, including datasets with 2, 3, and 4 corrupted signals with irradiance variations and grid voltage disturbances. Results demonstrate that the DD-DT achieves superior predictive accuracy (MAE ∼ 3.40%, MAPE ∼ 3.17%, and correlation coefficient ≥ 0.971) compared to conventional DT approaches. The proposed reliability-centric DD-DT thus provides a scalable pathway toward reliable DTs for power electronic circuits in renewable energy systems.
- 10 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Reliability
- Vol. 75 (00189529) , 2145-2158
System Modeling-Based Verification of Datasets for Reliable Data-Driven Digital Twin Development in Grid-Connected Solar Photovoltaic Inverter
Ensuring reliable operation of grid-tied photovoltaic (PV) inverters is critical as semiconductor aging, environmental variability, and grid disturbances pose major threats to system stability. This work presents a Data-Driven Digital Twin (DD-DT) framework for real-time predictive monitoring of a two-stage single-phase grid-connected PV inverter, incorporating Physics-Aware Statistical Cross Validation (PASCV) and Temporal Convolutional Networks (TCN). The proposed framework addresses critical challenges such as sensor noise, measurement faults, and system variations by integrating a physics-based validation layer with DD learning. PASCV ensures only trusted measurements are used for model training and real-time synchronization, while TCN enables high-fidelity time-domain prediction of key inverter states under dynamic operating conditions. Experimental validation is carried out on an NIsbRIO-OPAL-RT-based hardware testbed under diverse scenarios, including datasets with 2, 3, and 4 corrupted signals with irradiance variations and grid voltage disturbances. Results demonstrate that the DD-DT achieves superior predictive accuracy (MAE ∼ 3.40%, MAPE ∼ 3.17%, and correlation coefficient ≥ 0.971) compared to conventional DT approaches. The proposed reliability-centric DD-DT thus provides a scalable pathway toward reliable DTs for power electronic circuits in renewable energy systems.
- 15 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 23 (15455955) , 9858-9869
Digital-Twin-Based Parameter Estimation and Health Monitoring of Single-Stage Grid-Connected PV Systems via C-EFOm and Control Automation
This paper presents an enhanced digital twin framework for a single-stage three-phase grid-connected solar PV system, addressing limitations of existing digital twin approaches that rely on offline calibration or data-driven surrogates with limited interpretability. Prior studies often infer component aging indirectly and struggle to reconstruct internal electrical parameters under switching operation. To overcome these gaps, a unified digital twin architecture integrating real-time parameter estimation, control automation, and health monitoring is developed. A Predictive Drift-Free Maximum Power Point Tracking (PDF-MPPT) algorithm enables fast, oscillation-free power extraction without training data. Current regulation is achieved using a Delay-Compensated Predictive Deadbeat Model Predictive Control (DCP-DBC-MPC) strategy to mitigate delay effects and improve dynamic response. Internal parameter estimation is performed using a modified Coulomb-based Electromagnetic Field Optimization algorithm (C-EFOm), enabling online estimation of interfacing inductors, inverter switching resistances, ripple-filter elements, and DC-link capacitor parameters. To quantify accuracy, a Digital Twin Fidelity Score (DTFS) is introduced for waveform-level comparison between physical and virtual systems. Health monitoring is demonstrated through controlled degradation of inductors, capacitors, and switches using radar plots and waveform analysis. Experimental validation confirms fidelity and parameter tracking.
- 15 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 23 (15455955) , 9858-9869
Digital-Twin-Based Parameter Estimation and Health Monitoring of Single-Stage Grid-Connected PV Systems via C-EFOm and Control Automation
This paper presents an enhanced digital twin framework for a single-stage three-phase grid-connected solar PV system, addressing limitations of existing digital twin approaches that rely on offline calibration or data-driven surrogates with limited interpretability. Prior studies often infer component aging indirectly and struggle to reconstruct internal electrical parameters under switching operation. To overcome these gaps, a unified digital twin architecture integrating real-time parameter estimation, control automation, and health monitoring is developed. A Predictive Drift-Free Maximum Power Point Tracking (PDF-MPPT) algorithm enables fast, oscillation-free power extraction without training data. Current regulation is achieved using a Delay-Compensated Predictive Deadbeat Model Predictive Control (DCP-DBC-MPC) strategy to mitigate delay effects and improve dynamic response. Internal parameter estimation is performed using a modified Coulomb-based Electromagnetic Field Optimization algorithm (C-EFOm), enabling online estimation of interfacing inductors, inverter switching resistances, ripple-filter elements, and DC-link capacitor parameters. To quantify accuracy, a Digital Twin Fidelity Score (DTFS) is introduced for waveform-level comparison between physical and virtual systems. Health monitoring is demonstrated through controlled degradation of inductors, capacitors, and switches using radar plots and waveform analysis. Experimental validation confirms fidelity and parameter tracking.
- 21 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-10
State-Space Based Digital Twin of Single-Stage PV Inverter With Predictive Control for Real-Time Stability Monitoring
Real-time monitoring and predictive control are critical for ensuring stability and efficiency in grid-connected photovoltaic (PV) systems. However, conventional methods often lack dynamic system representation and stability assurance under inverter switching conditions. This article presents a digital twin (DT) framework based on discrete-time state-space modeling in the frequency domain for a single-stage three-phase grid-connected PV inverter. The proposed Digital Twin operates in parallel with the physical system to reconstruct internal states and continuously monitor stability under practical inverter switching conditions. The DT integrates a cascaded second and third-order generalized integrator–noise suppression block–compact generalized integrator (CSTOGI–NSB–CGI) filtering structure for robust voltage template extraction, a second horizon–loss minimized voltage-regulated model predictive control (SH-LMVR-MPC) strategy for dynamic current regulation, real-time internal parameter estimation using magnetic-domain alignment electromagnetic field optimization (MDA-EFO), and real-time stability monitoring. Controller and system stability are rigorously verified using discrete-time Lyapunov criteria, with real-time evaluation performed every 10 ms for control and every 20 ms for system verification. Experimental validation is conducted on an OPAL-RT (OP4512) real-time simulator and a NI sbRIO-9636 FPGA controller. Performance evaluation shows grid current THD consistently below 4.5% (IEEE-519 compliant), digital twin fidelity score (DTFS) exceeding 97% across test scenarios, and parameter estimation converging within 20 iterations, confirming high-fidelity system replication and reliable real-time operation.
- 21 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-10
State-Space Based Digital Twin of Single-Stage PV Inverter With Predictive Control for Real-Time Stability Monitoring
Real-time monitoring and predictive control are critical for ensuring stability and efficiency in grid-connected photovoltaic (PV) systems. However, conventional methods often lack dynamic system representation and stability assurance under inverter switching conditions. This article presents a digital twin (DT) framework based on discrete-time state-space modeling in the frequency domain for a single-stage three-phase grid-connected PV inverter. The proposed Digital Twin operates in parallel with the physical system to reconstruct internal states and continuously monitor stability under practical inverter switching conditions. The DT integrates a cascaded second and third-order generalized integrator–noise suppression block–compact generalized integrator (CSTOGI–NSB–CGI) filtering structure for robust voltage template extraction, a second horizon–loss minimized voltage-regulated model predictive control (SH-LMVR-MPC) strategy for dynamic current regulation, real-time internal parameter estimation using magnetic-domain alignment electromagnetic field optimization (MDA-EFO), and real-time stability monitoring. Controller and system stability are rigorously verified using discrete-time Lyapunov criteria, with real-time evaluation performed every 10 ms for control and every 20 ms for system verification. Experimental validation is conducted on an OPAL-RT (OP4512) real-time simulator and a NI sbRIO-9636 FPGA controller. Performance evaluation shows grid current THD consistently below 4.5% (IEEE-519 compliant), digital twin fidelity score (DTFS) exceeding 97% across test scenarios, and parameter estimation converging within 20 iterations, confirming high-fidelity system replication and reliable real-time operation.
- 9 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Cyber-Physical Systems
- Vol. 4, 238-245
Predictive ConvFormer-LSTM Digital Twin for Intelligent Cyber-Physical Operation of Grid-Connected Photovoltaic Systems
In this paper, an intelligent cyber physical data driven Digital Twin (DT) framework is developed for monitoring and performance enhancement of grid-connected photovoltaic (PV) systems. The developed DT framework integrates sensing, modeling, and learning within a unified cyber-physical environment for accurate system state representation and effective control. The proposed framework employs a hybrid ConvFormer-LSTM architecture, which integrates convolutional feature extraction, Transformer-based attention mechanism, and Long Short-Term Memory (LSTM) to jointly capture local transients and long-range temporal dependencies in multivariate time-series signals. The framework enables accurate estimation of voltage and current stresses, as well as non-invasive parameter identification of critical components, using predicted voltage and current signals. Validation on a 2-stage, 3-phase grid-connected photovoltaic (PV) energy conversion system demonstrates that the proposed method achieves a coefficient of determination (R²) of 0.9573 under hybrid dynamic conditions, with low MAPE values such as 1.78. These results confirm that the proposed DT methodology provides a robust and generalizable solution for monitoring and parameter estimation in nonlinear circuit and system environments.
- 9 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Cyber-Physical Systems
- Vol. 4, 238-245
Predictive ConvFormer-LSTM Digital Twin for Intelligent Cyber-Physical Operation of Grid-Connected Photovoltaic Systems
In this paper, an intelligent cyber physical data driven Digital Twin (DT) framework is developed for monitoring and performance enhancement of grid-connected photovoltaic (PV) systems. The developed DT framework integrates sensing, modeling, and learning within a unified cyber-physical environment for accurate system state representation and effective control. The proposed framework employs a hybrid ConvFormer-LSTM architecture, which integrates convolutional feature extraction, Transformer-based attention mechanism, and Long Short-Term Memory (LSTM) to jointly capture local transients and long-range temporal dependencies in multivariate time-series signals. The framework enables accurate estimation of voltage and current stresses, as well as non-invasive parameter identification of critical components, using predicted voltage and current signals. Validation on a 2-stage, 3-phase grid-connected photovoltaic (PV) energy conversion system demonstrates that the proposed method achieves a coefficient of determination (R²) of 0.9573 under hybrid dynamic conditions, with low MAPE values such as 1.78. These results confirm that the proposed DT methodology provides a robust and generalizable solution for monitoring and parameter estimation in nonlinear circuit and system environments.
- 3 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 72 (2) , 3018-3026
Seamless Dual Mode Control Strategy for Wide Soft Switching Range in Consumer-Centric Dual Active Bridge Converters
The realization of Zero Voltage Switching (ZVS) for all active switches throughout the operating range is critical to achieve high efficiency and meet the power density requirements of modern isolated bidirectional single-stage DC–DC converters. This paper proposes a novel Seamless Dual Mode Control (SDMC) strategy for the Dual Active Bridge (DAB) converter, enabling the full load range ZVS of all switches while minimizing transformer peak current. Two control variables are introduced to govern the respective operating modes, facilitating optimal control across a wide output voltage range. A detailed analysis of ZVS conditions and transformer peak current behaviour are presented for each mode, explicitly considering the impact of switch junction capacitance and transformer magnetizing inductance. Based on these analytical models, a unified control scheme is developed to ensure complete ZVS, minimized peak current, and seamless mode transitions without compromising system performance. Comparative evaluations demonstrate that SDMC significantly improves conversion efficiency relative to conventional phase shift (CPS) control, extended phase shift with current stress optimization (EPS-CSO), and other state-of-the-art techniques. Experimental results obtained from a 5.5 kW laboratory prototype validate the effectiveness of the proposed SDMC method. The proposed approach offers a promising solution for enhancing the performance and reliability of high-power isolated bidirectional DC-DC converters operating under wide voltage.
- 3 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 72 (2) , 3018-3026
Seamless Dual Mode Control Strategy for Wide Soft Switching Range in Consumer-Centric Dual Active Bridge Converters
The realization of Zero Voltage Switching (ZVS) for all active switches throughout the operating range is critical to achieve high efficiency and meet the power density requirements of modern isolated bidirectional single-stage DC–DC converters. This paper proposes a novel Seamless Dual Mode Control (SDMC) strategy for the Dual Active Bridge (DAB) converter, enabling the full load range ZVS of all switches while minimizing transformer peak current. Two control variables are introduced to govern the respective operating modes, facilitating optimal control across a wide output voltage range. A detailed analysis of ZVS conditions and transformer peak current behaviour are presented for each mode, explicitly considering the impact of switch junction capacitance and transformer magnetizing inductance. Based on these analytical models, a unified control scheme is developed to ensure complete ZVS, minimized peak current, and seamless mode transitions without compromising system performance. Comparative evaluations demonstrate that SDMC significantly improves conversion efficiency relative to conventional phase shift (CPS) control, extended phase shift with current stress optimization (EPS-CSO), and other state-of-the-art techniques. Experimental results obtained from a 5.5 kW laboratory prototype validate the effectiveness of the proposed SDMC method. The proposed approach offers a promising solution for enhancing the performance and reliability of high-power isolated bidirectional DC-DC converters operating under wide voltage.
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. PP (00983063) , 1
Consumer-Oriented Stability Augmentation of 2-Stage 1-Phase Solar PV Systems Using Digital Twin
This paper presents the stability monitoring of a consumer-oriented two-stage single-phase grid-connected solar photovoltaic (SPV) system using Digital Twin (DT) subjected to various perturbations. The DT is meticulously developed utilizing discretized equations derived from the Backward-Euler method augmented by the Enhanced Momentum Search Optimization (EMSA) algorithm to optimize system tuning and facilitate effective data collaboration and proposed Limit Cycle Oscillator Tuned Generalized Integrator-Unit Vector Template (LCOGI-UVT) for the pre-eminent control of inverter. This integration ensures a more refined and efficient modeling process, enhancing the overall performance and reliability of the DT. Following the establishment of the DT’s operational integrity, the stability of this model is systematically assessed at every operational point through the application of the Lyapunov approach. Additionally, the stability of a proposed control strategy is monitored using the Jacobian methodology. The DT for the system is implemented in OPAL-RT, with experimental validation conducted on a physical testbed, confirming the model's robustness, accuracy (> 98%), and relevance for intelligent consumer electronic systems.
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. PP (00983063) , 1
Consumer-Oriented Stability Augmentation of 2-Stage 1-Phase Solar PV Systems Using Digital Twin
This paper presents the stability monitoring of a consumer-oriented two-stage single-phase grid-connected solar photovoltaic (SPV) system using Digital Twin (DT) subjected to various perturbations. The DT is meticulously developed utilizing discretized equations derived from the Backward-Euler method augmented by the Enhanced Momentum Search Optimization (EMSA) algorithm to optimize system tuning and facilitate effective data collaboration and proposed Limit Cycle Oscillator Tuned Generalized Integrator-Unit Vector Template (LCOGI-UVT) for the pre-eminent control of inverter. This integration ensures a more refined and efficient modeling process, enhancing the overall performance and reliability of the DT. Following the establishment of the DT’s operational integrity, the stability of this model is systematically assessed at every operational point through the application of the Lyapunov approach. Additionally, the stability of a proposed control strategy is monitored using the Jacobian methodology. The DT for the system is implemented in OPAL-RT, with experimental validation conducted on a physical testbed, confirming the model's robustness, accuracy (> 98%), and relevance for intelligent consumer electronic systems.
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. PP (00983063) , 1
Consumer-Centric Control of Grid-Interactive PV Systems Using AGI-CTS-MPC-SODA for Enhanced Power Quality and Reliability
The integration of renewable energy sources with weak distribution grid and local highly nonlinear loads, such as solar photovoltaics (PV), demands the development of advanced control strategies to address key challenges, including the optimization of controller parameters, ensuring DC-link voltage stability, supply optimal nonlinear power to local consumers, and achieving robust synchronization with the grid at Point of Common Coupling (PCC). This paper introduces a novel AGI (Advanced Generalised Integrator)-CTS (Chi-square Teager-Kaiser energy operator Selfish herd optimizer)-MPC (Model Predictive Control) with SODA (Second Order Derivative based Adaptive) control strategy for 3-phase single-stage grid-interactive PV systems. Here, AGI is used to filter the harmonics from the grid voltage, which is used for unit template generation for accurate grid synchronization. It is also used with consumer load to estimate the active and nonlinear power requirement. CTS is used for controller parameter tuning in dynamic condition, specially when variation is large and rapid. MPC is used for optimal switching pulse generation for inverter by minimizing error and improving grid current quality. SODA is used for accurate maximum power peak detection, specially when solar PV irradiation is changing very drastically. This AGI-CTS-MPC-SODA control strategy is dedicatedly designed and developed for 3-phase single-stage grid-interactive PV systems. The developed control strategy is tested on hardware prototype under different adverse grid, load and solar condition, demonstrates significant improvements in DC-link voltage stability, power quality, and system reliability, making this approach highly suitable for next-generation consumer power electronics.
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. PP (00983063) , 1
Consumer-Centric Control of Grid-Interactive PV Systems Using AGI-CTS-MPC-SODA for Enhanced Power Quality and Reliability
The integration of renewable energy sources with weak distribution grid and local highly nonlinear loads, such as solar photovoltaics (PV), demands the development of advanced control strategies to address key challenges, including the optimization of controller parameters, ensuring DC-link voltage stability, supply optimal nonlinear power to local consumers, and achieving robust synchronization with the grid at Point of Common Coupling (PCC). This paper introduces a novel AGI (Advanced Generalised Integrator)-CTS (Chi-square Teager-Kaiser energy operator Selfish herd optimizer)-MPC (Model Predictive Control) with SODA (Second Order Derivative based Adaptive) control strategy for 3-phase single-stage grid-interactive PV systems. Here, AGI is used to filter the harmonics from the grid voltage, which is used for unit template generation for accurate grid synchronization. It is also used with consumer load to estimate the active and nonlinear power requirement. CTS is used for controller parameter tuning in dynamic condition, specially when variation is large and rapid. MPC is used for optimal switching pulse generation for inverter by minimizing error and improving grid current quality. SODA is used for accurate maximum power peak detection, specially when solar PV irradiation is changing very drastically. This AGI-CTS-MPC-SODA control strategy is dedicatedly designed and developed for 3-phase single-stage grid-interactive PV systems. The developed control strategy is tested on hardware prototype under different adverse grid, load and solar condition, demonstrates significant improvements in DC-link voltage stability, power quality, and system reliability, making this approach highly suitable for next-generation consumer power electronics.
- 20 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. PP (15498328) , 1-12
State-Space Model-Based Digital Twin With Real-Time Parameter Optimization Using MDA-EFO for Grid-Connected PV Inverter Systems
This paper proposes a Digital Twin (DT) framework for a single-stage, three-phase grid-connected photovoltaic (PV) inverter system, leveraging discrete-time state-space modelling in frequency domain for accurate dynamic representation under all switching conditions. The DT integrates a novel CSTOGI-NSB-CGI (Cascaded Second and Third-Order Generalized Integrator, Noise Suppression Block, Compact Generalized Integrator) filter for robust extraction of the fundamental grid voltage, even during voltage unbalance, distortion, and harmonic conditions. To maintain precise current regulation and consistent switching frequency, an Adaptive Hysteresis Band Current Controller (AHBCC) is implemented. For real-time tuning of inverter parameters, a Magnetic-Domain Alignment Electromagnetic Field Optimization (MDA-EFO) algorithm is introduced, offering fast convergence through dual-force interaction involving global best and peer alignment. MDA-EFO is deployed on an OPAL-RT HIL platform for real-time experiments; the algorithm is platform-agnostic and can also be implemented in MATLAB/Simulink or other real-time environments. The DT framework accurately estimates internal system parameters, such as inductances, resistances, and filter capacitances, without relying on external training data. Experimental validation using real-time hardware measurements confirms the DT’s high-fidelity performance, as supported by the Digital Twin Fidelity Score (DTFS) metric. The results demonstrate the DT’s capability for real-time monitoring, adaptive optimization, and predictive diagnostics in grid-connected PV applications.
- 20 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. PP (15498328) , 1-12
State-Space Model-Based Digital Twin With Real-Time Parameter Optimization Using MDA-EFO for Grid-Connected PV Inverter Systems
This paper proposes a Digital Twin (DT) framework for a single-stage, three-phase grid-connected photovoltaic (PV) inverter system, leveraging discrete-time state-space modelling in frequency domain for accurate dynamic representation under all switching conditions. The DT integrates a novel CSTOGI-NSB-CGI (Cascaded Second and Third-Order Generalized Integrator, Noise Suppression Block, Compact Generalized Integrator) filter for robust extraction of the fundamental grid voltage, even during voltage unbalance, distortion, and harmonic conditions. To maintain precise current regulation and consistent switching frequency, an Adaptive Hysteresis Band Current Controller (AHBCC) is implemented. For real-time tuning of inverter parameters, a Magnetic-Domain Alignment Electromagnetic Field Optimization (MDA-EFO) algorithm is introduced, offering fast convergence through dual-force interaction involving global best and peer alignment. MDA-EFO is deployed on an OPAL-RT HIL platform for real-time experiments; the algorithm is platform-agnostic and can also be implemented in MATLAB/Simulink or other real-time environments. The DT framework accurately estimates internal system parameters, such as inductances, resistances, and filter capacitances, without relying on external training data. Experimental validation using real-time hardware measurements confirms the DT’s high-fidelity performance, as supported by the Digital Twin Fidelity Score (DTFS) metric. The results demonstrate the DT’s capability for real-time monitoring, adaptive optimization, and predictive diagnostics in grid-connected PV applications.