Cassidy Yoshida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Cassidy Yoshida has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Peter Kennealey
Department of Surgery, University of Colorado School of Medicine, Aurora, CO, 80045, USA
3 shared publications- Rashikh Ahmed Choudhury
Department of Surgery, University of Colorado Anschutz Medical Campus, Aurora, CO
3 shared publications James Cooper
Department of Medicine, University of Colorado School of Medicine, Aurora, CO, 80045, USA
2 shared publications- Keith S. Hansen
Department of Surgery University of Colorado School of Medicine Aurora Colorado USA
2 shared publications - Marissa Di Napoli
University of Colorado, Department of Surgery, Division of Transplant Surgery, Aurora, CO, USA; Willis-Knighton Health System, Department of Surgery, Shreveport, LA, USA
2 shared publications - Phillipe Abreu
Department of Surgery Tufts Medical Center Boston Massachusetts USA
2 shared publications
Latest Publications
- 19 September 2026
- Published by Elsevier in The American Journal of Surgery
- Vol. 262, 117245
Outcomes after robotic and open kidney transplant: A propensity score-matched analysis
- 19 September 2026
- Published by Elsevier in The American Journal of Surgery
- Vol. 262, 117245
Outcomes after robotic and open kidney transplant: A propensity score-matched analysis
- Open Access
- 1 July 2026
- Published by Wolters Kluwer Health in Kidney360
- Vol. 7 (10) , 2355-2362
Safety in Robotic Kidney Transplant for All-Comers
Key Points: Robotic kidney transplantation demonstrates equivalent perioperative safety across body mass index strata, including body mass index ≥40 kg/m 2 . High body mass index alone was not associated with higher surgical complexity, delayed graft function, or early graft loss. Robotic kidney transplant may expand equitable access to transplantation by mitigating traditional obesity-related surgical risks. Background: Obesity remains a common barrier to kidney transplantation, with many centers enforcing strict body mass index (BMI) cutoffs because of concerns regarding surgical complexity and postoperative complications. Robotic kidney transplantation (RKT) has emerged as a minimally invasive alternative that may mitigate obesity-associated surgical risks. However, outcomes across granular BMI subgroups, particularly among patients with morbid obesity (BMI ≥40 kg/m 2 ), remain incompletely characterized. Methods: We performed a retrospective cohort study of adult patients undergoing RKT at a single academic transplant center between November 2021 and September 2025. Patients were stratified by BMI into two primary cohorts (BMI 2 ) with a secondary subgroup analysis comparing those with BMI 30–40 versus ≥40 kg/m 2 . Demographic characteristics, intraoperative metrics, and 30-day postoperative outcomes were compared. Results: A total of 104 patients underwent RKT, with 26 patients with BMI 2 , 53 with BMI between 30 and 40 kg/m 2 , and 25 with BMI ≥40 kg/m 2 . No significant differences were observed between BMI P = 0.03). In subgroup analysis, patients with BMI ≥40 demonstrated comparable intraoperative parameters and postoperative complication rates to those with BMI 30–40, with no significant differences in graft or patient survival. Conclusions: RKT is associated with comparable perioperative outcomes across BMI categories, including among patients with morbid obesity. These findings challenge rigid BMI-based exclusion criteria and support a more individualized approach to transplant candidacy in the era of robotic surgery.
- 1 July 2026
- Published by Wolters Kluwer Health in Kidney360
- Vol. 7 (10) , 2355-2362
Open AccessSafety in Robotic Kidney Transplant for All-Comers
Key Points: Robotic kidney transplantation demonstrates equivalent perioperative safety across body mass index strata, including body mass index ≥40 kg/m 2 . High body mass index alone was not associated with higher surgical complexity, delayed graft function, or early graft loss. Robotic kidney transplant may expand equitable access to transplantation by mitigating traditional obesity-related surgical risks. Background: Obesity remains a common barrier to kidney transplantation, with many centers enforcing strict body mass index (BMI) cutoffs because of concerns regarding surgical complexity and postoperative complications. Robotic kidney transplantation (RKT) has emerged as a minimally invasive alternative that may mitigate obesity-associated surgical risks. However, outcomes across granular BMI subgroups, particularly among patients with morbid obesity (BMI ≥40 kg/m 2 ), remain incompletely characterized. Methods: We performed a retrospective cohort study of adult patients undergoing RKT at a single academic transplant center between November 2021 and September 2025. Patients were stratified by BMI into two primary cohorts (BMI 2 ) with a secondary subgroup analysis comparing those with BMI 30–40 versus ≥40 kg/m 2 . Demographic characteristics, intraoperative metrics, and 30-day postoperative outcomes were compared. Results: A total of 104 patients underwent RKT, with 26 patients with BMI 2 , 53 with BMI between 30 and 40 kg/m 2 , and 25 with BMI ≥40 kg/m 2 . No significant differences were observed between BMI P = 0.03). In subgroup analysis, patients with BMI ≥40 demonstrated comparable intraoperative parameters and postoperative complication rates to those with BMI 30–40, with no significant differences in graft or patient survival. Conclusions: RKT is associated with comparable perioperative outcomes across BMI categories, including among patients with morbid obesity. These findings challenge rigid BMI-based exclusion criteria and support a more individualized approach to transplant candidacy in the era of robotic surgery.
- 15 May 2026
- Published by Elsevier in The American Journal of Surgery
- Vol. 261, 117027
Sleeve gastrectomy versus tirzepatide to improve survival among patients with stage 5 CKD: A Markov decision analysis
- 15 May 2026
- Published by Elsevier in The American Journal of Surgery
- Vol. 261, 117027
Sleeve gastrectomy versus tirzepatide to improve survival among patients with stage 5 CKD: A Markov decision analysis
- 9 April 2026
- Published by Elsevier in The American Journal of Surgery
- Vol. 260, 116979
Patient-reported outcomes and attitudes in patients at high-risk for breast cancer
- 9 April 2026
- Published by Elsevier in The American Journal of Surgery
- Vol. 260, 116979
Patient-reported outcomes and attitudes in patients at high-risk for breast cancer
- Open Access
- 27 August 2025
- Published by California Digital Library (CDL) in Clinical Practice and Cases in Emergency Medicine
- Vol. 9 (4) , 404-406
Female Menstrual Cup Causing Renal Colic, Hydronephrosis, and Ureteral Stricture: A Case Report
Introduction: Renal colic is a common reason for patients to present to the emergency department (ED). The most common reasons for this pain are usually renal in origin. Here we present the case of a 45-year-old woman with severe right-sided flank pain and associated hydronephrosis secondary to ureteral obstruction caused by the suction of a menstrual cup. Case Report: A 45-year-old female presented to the ED with sudden severe right-sided flank pain. The patient endorsed nausea without vomiting, fever, chills, hematuria, or dysuria. She stated that she was currently having her menstrual period. On physical exam, the patient was in distress but had no tenderness with palpation of the flank or abdomen. A computed tomography of the kidneys, ureters, and bladder did not show renal or ureteral stones but demonstrated right-sided hydronephrosis secondary to an anatomical blockage of the ureter, which had been suctioned and involuted into a malpositioned menstrual cup. The patient removed her menstrual cup and had immediate relief of her symptoms. She was observed and remained completely asymptomatic upon reassessment two hours later. Conclusion: Ureteral obstruction and hydronephrosis is a rare complication of menstrual cup use. As these devices become more common, emergency physicians must be aware of this complication as a cause of severe back pain in menstruating women.
- 27 August 2025
- Published by California Digital Library (CDL) in Clinical Practice and Cases in Emergency Medicine
- Vol. 9 (4) , 404-406
Open AccessFemale Menstrual Cup Causing Renal Colic, Hydronephrosis, and Ureteral Stricture: A Case Report
Introduction: Renal colic is a common reason for patients to present to the emergency department (ED). The most common reasons for this pain are usually renal in origin. Here we present the case of a 45-year-old woman with severe right-sided flank pain and associated hydronephrosis secondary to ureteral obstruction caused by the suction of a menstrual cup. Case Report: A 45-year-old female presented to the ED with sudden severe right-sided flank pain. The patient endorsed nausea without vomiting, fever, chills, hematuria, or dysuria. She stated that she was currently having her menstrual period. On physical exam, the patient was in distress but had no tenderness with palpation of the flank or abdomen. A computed tomography of the kidneys, ureters, and bladder did not show renal or ureteral stones but demonstrated right-sided hydronephrosis secondary to an anatomical blockage of the ureter, which had been suctioned and involuted into a malpositioned menstrual cup. The patient removed her menstrual cup and had immediate relief of her symptoms. She was observed and remained completely asymptomatic upon reassessment two hours later. Conclusion: Ureteral obstruction and hydronephrosis is a rare complication of menstrual cup use. As these devices become more common, emergency physicians must be aware of this complication as a cause of severe back pain in menstruating women.