Youlian Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Youlian Wang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Xiaolan Li
Tianjin University of Technology
2 shared publications - Yinping Miao
School of Integrated Circuit Science and Engineering, Tianjin University of Technology, Tianjin, China
2 shared publications Changping Xu
Tianjin Key Laboratory of Film Electronic and Communication Device, School of Integrated Circuit Science and Engineering, Tianjin University of Technology 1 , Tianjin 300384
1 shared publicationJianquan Yao
College of Precision Instrument and Optoelectronics Engineering, Institute of Laser and Opto-Electronics, Tianjin University 2 , Tianjin 300072
1 shared publication- Jianquan Yao
Tianjin University
1 shared publication Ning Li
Tianjin University of Technology, School of Integrated Circuit Science and Engineering, Optical-fiber Photonics Research Group, Tianjin, China
1 shared publication
Latest Publications
- 19 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (13) , 19645-19651
High-Sensitivity PDMS Film-Based Fabry–Pérot Interferometer for Magnetic Field Sensing via Magnetic Fluid Volume Effect
reflective fiber-optic magnetic field sensor based on the magnetic fluid (MF) magnetic volume effect is proposed. The sensor incorporates a Fabry-Pérot (F-P) interference structure formed by a single-mode fiber (SMF) and a polydimethylsiloxane (PDMS) film. By detecting the volume changes of MF under varying magnetic field strengths, the sensor achieves highly sensitive magnetic field measurement. When exposed to an external magnetic field, the nanoparticles in the MF undergo oriented alignment, resulting in anisotropic volume changes. These changes are transmitted to the F-P air cavity via the PDMS film, enabling precise measurement of magnetic field intensity. Experimental results demonstrate that with a 48.4 μm-thick PDMS film, the sensor achieves axial and radial magnetic field sensitivities of -2.3 nm/mT and -2.73 nm/mT, respectively, within the 0-12 mT range. Furthermore, we observed that reducing the PDMS film thickness significantly enhances magnetic field sensitivity. After optimization to 46.92 μm, the sensor achieved a radial sensitivity of -9.40 nm/mT, a detection limit of 0.0021 mT, and excellent linearity (R2 = 0.9988). The sensor combines the advantages of simple structure, high sensitivity and low fabrication cost, which provides a new solution for magnetic field measurement in the fields of power equipment monitoring and aerospace.
- 19 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (13) , 19645-19651
High-Sensitivity PDMS Film-Based Fabry–Pérot Interferometer for Magnetic Field Sensing via Magnetic Fluid Volume Effect
reflective fiber-optic magnetic field sensor based on the magnetic fluid (MF) magnetic volume effect is proposed. The sensor incorporates a Fabry-Pérot (F-P) interference structure formed by a single-mode fiber (SMF) and a polydimethylsiloxane (PDMS) film. By detecting the volume changes of MF under varying magnetic field strengths, the sensor achieves highly sensitive magnetic field measurement. When exposed to an external magnetic field, the nanoparticles in the MF undergo oriented alignment, resulting in anisotropic volume changes. These changes are transmitted to the F-P air cavity via the PDMS film, enabling precise measurement of magnetic field intensity. Experimental results demonstrate that with a 48.4 μm-thick PDMS film, the sensor achieves axial and radial magnetic field sensitivities of -2.3 nm/mT and -2.73 nm/mT, respectively, within the 0-12 mT range. Furthermore, we observed that reducing the PDMS film thickness significantly enhances magnetic field sensitivity. After optimization to 46.92 μm, the sensor achieved a radial sensitivity of -9.40 nm/mT, a detection limit of 0.0021 mT, and excellent linearity (R2 = 0.9988). The sensor combines the advantages of simple structure, high sensitivity and low fabrication cost, which provides a new solution for magnetic field measurement in the fields of power equipment monitoring and aerospace.
- 18 August 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 127 (7)
In situ detection of sodium nitrate and sodium nitrite using a cascade Fabry–Perot interferometer based on the photothermal effect
Nitrates and nitrites, as food additives, are extensively used in the curing and preservation of meat and vegetable products. Excessive intake can impair the blood's oxygen-carrying capacity and pose serious health risks, including carcinogenic potential. This paper presents a cascaded fiber-optic Fabry–Pérot (F-P) sensing technique for the simultaneous detection of sodium nitrate and sodium nitrite based on the photothermal properties of the target substances. The proposed sensor unit consists of a cascaded F-P cavity made up of a single-mode optical fiber, a polyurethane film, and a gold film. Experimental results demonstrate that under 222 nm pump light source irradiation, the sensor achieves a sensitivity of 55.342 nm/(mg/L) and a detection limit of 0.316 μg/L, four orders of magnitude lower than traditional high-performance liquid chromatography. With its compact structure and high sensitivity, the sensor enables in situ detection, offering significant potential for applications in food safety monitoring, drug testing, and disease diagnostics without requiring sample pretreatment.
- 18 August 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 127 (7)
In situ detection of sodium nitrate and sodium nitrite using a cascade Fabry–Perot interferometer based on the photothermal effect
Nitrates and nitrites, as food additives, are extensively used in the curing and preservation of meat and vegetable products. Excessive intake can impair the blood's oxygen-carrying capacity and pose serious health risks, including carcinogenic potential. This paper presents a cascaded fiber-optic Fabry–Pérot (F-P) sensing technique for the simultaneous detection of sodium nitrate and sodium nitrite based on the photothermal properties of the target substances. The proposed sensor unit consists of a cascaded F-P cavity made up of a single-mode optical fiber, a polyurethane film, and a gold film. Experimental results demonstrate that under 222 nm pump light source irradiation, the sensor achieves a sensitivity of 55.342 nm/(mg/L) and a detection limit of 0.316 μg/L, four orders of magnitude lower than traditional high-performance liquid chromatography. With its compact structure and high sensitivity, the sensor enables in situ detection, offering significant potential for applications in food safety monitoring, drug testing, and disease diagnostics without requiring sample pretreatment.
- 1 December 2024
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 63 (12) , 126103-11
Highly integrated hollow-core anti-resonant fiber magnetic field sensor based on surface plasmon resonance
With the development of information technology, magnetic field detection plays a vital role in fields such as geological exploration. We propose a hollow-core anti-resonant fiber (HC-ARF) magnetic field sensor based on surface plasmon resonance, which is designed to excite surface plasma polariton modes by plating a gold film in the cladding tube of the HC-ARF, and we select an air cladding filled with magnetic fluid for magnetic field sensitivity detection. We analyzed the sensing characteristics of the sensor using the finite element method and studied in depth the effect of the gold film thickness on the magnetic field sensitivity. In our experiment, a maximum wavelength sensitivity of 101.92 pm/Oe was obtained in a magnetic field range of 60 to 180 Oe with a detection limit of 0.1962 Oe. The proposed sensor has the advantages of low loss and high sensitivity, which shows potential applications in the fields of geology, biomedicine, and military.
- 1 December 2024
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 63 (12) , 126103-11
Highly integrated hollow-core anti-resonant fiber magnetic field sensor based on surface plasmon resonance
With the development of information technology, magnetic field detection plays a vital role in fields such as geological exploration. We propose a hollow-core anti-resonant fiber (HC-ARF) magnetic field sensor based on surface plasmon resonance, which is designed to excite surface plasma polariton modes by plating a gold film in the cladding tube of the HC-ARF, and we select an air cladding filled with magnetic fluid for magnetic field sensitivity detection. We analyzed the sensing characteristics of the sensor using the finite element method and studied in depth the effect of the gold film thickness on the magnetic field sensitivity. In our experiment, a maximum wavelength sensitivity of 101.92 pm/Oe was obtained in a magnetic field range of 60 to 180 Oe with a detection limit of 0.1962 Oe. The proposed sensor has the advantages of low loss and high sensitivity, which shows potential applications in the fields of geology, biomedicine, and military.