    Research on FOPID Controller and CMOPSO Optimization for Prevention and Control of Oscillatory Instability at the PCC in a Hydro–Wind–Photovoltaic Grid-Connected System

    by Bojin Tang, Weiwei Yao, Teng Yi, Rui Lv, Zhi Wang, Chaoshun Li

    To address the key problems of low-frequency oscillation and insufficient regulation accuracy at the Point of Common Coupling (PCC) in hydro–wind–photovoltaic hybrid systems, which are caused by the randomness of wind and photovoltaic output, the water-hammer effect of hydropower units, and multi-source power coupling, a joint control strategy based on Fractional-Order Proportional Integral Derivative (FOPID) and Co-evolutionary Multi-objective Particle Swarm Optimization (CMOPSO) is proposed. First, a small-signal transfer function model of the system covering photovoltaic inverters, doubly fed induction generators (DFIGs), hydropower units and voltage-source converter-based high-voltage direct current (VSC-HVDC) converter stations is established to accurately characterize the water-hammer effect and multi-source dynamic coupling characteristics. Second, a Caputo-type FOPID controller is designed. Compared with traditional integer-order controllers with limited tuning flexibility, the FOPID controller utilizes its five degrees of freedom to address specific multi-source coupling challenges. This precisely compensates for the non-minimum phase lag caused by the water-hammer effect in hydropower units via the fractional derivative link, and effectively smooths the impact of stochastic wind–solar fluctuations on PCC voltage through the memory characteristics of the fractional integral link. This multi-parameter regulation mechanism prevents a trade-off between response speed and overshoot suppression, achieving effective decoupling of complex multi-source dynamic interactions. Third, a dual-objective optimization framework with the Integral of Time-weighted Absolute Error (ITAE) and Oscillatory Disturbance Risk Index (ODRI) as the objectives is constructed. The multi-population co-evolution mechanism of the CMOPSO algorithm is adopted to solve the Pareto-optimal solution set, realizing the coordinated optimization of dynamic response accuracy and oscillation instability risk. Finally, comparative simulations are carried out on the Simulink platform with traditional PI/FOPI controllers and optimization algorithms such as Multi-objective Particle Swarm Optimization based on the Decomposition/Simple Indicator-Based Evolutionary Algorithm (MPSOD/SIBEA). The results show that the proposed strategy can effectively suppress low-frequency oscillations in the range of 0~30 Hz. Compared with the traditional PI controller, the PCC voltage overshoot is reduced by more than 40%, the oscillation decay time is shortened by 33%, the ITAE and ODRI indices are decreased by 12.58% and 2.47%, respectively, and the stability of DC bus voltage is significantly improved. Its robustness and comprehensive control performance are superior to existing methods, providing an efficient and stable control scheme for power electronics-dominated complex new energy grid-connected systems.


  • Open Access

    Multi-Scenario Optimization of PID Controllers for Hydro-Wind-Solar Complementary Systems Based on the DEAGNG Algorithm

    by Jun Yan, Zhi Wang, Yuye Li, An Yan, Shaoyong Liu, Jinwen Luo, Chu Zhang, Chaoshun Li

    This paper focuses on the hydro–solar–wind complementary system, targeting two typical scenarios (both include PV output fluctuations driven by solar radiation intensity: wind power not participating in frequency regulation and wind power participating in frequency regulation) to conduct research on system frequency characteristic analysis and Proportional-Integral-Derivative (PID) controller parameter (KP, KI) optimization. By constructing a frequency response model that accounts for wind power penetration and output fluctuations, the dynamic regulation characteristics of the system under different scenarios are quantitatively analyzed. Given the limitations of single-objective optimization algorithms in balancing multiple performance indicators, the Decomposition-based Evolutionary Algorithm Guided by Growing Neural Gas (DEAGNG) multi-objective algorithm is introduced, with the Integral Time Absolute Error (ITAE) and the Integral Time Squared Error (ITSE) as the objective functions for parameter collaborative optimization. The results show that the optimization method based on DEAGNG can effectively improve the frequency stability of the system, reduce the mean value and maximum deviation of frequency fluctuations, and exhibit good adaptability in both scenarios. This study provides a multi-scenario-adapted PID parameter optimization scheme for hydro–solar–wind complementary systems, offering theoretical and technical support for achieving high-precision frequency control and enhancing the operational reliability of the system.

  • Open Access

    Multi-Objective Optimized Fuzzy Fractional-Order PID Control for Frequency Regulation in Hydro–Wind–Solar–Storage Systems

    by Yuye Li, Chenghao Sun, Jun Yan, An Yan, Shaoyong Liu, Jinwen Luo, Zhi Wang, Chu Zhang, Chaoshun Li

    In the integrated hydro–wind–solar–storage system, the strong output fluctuations of wind and solar power, along with prominent system nonlinearity and time-varying characteristics, make it difficult for traditional PID controllers to achieve high-precision and robust dynamic control. This paper proposes a fuzzy fractional-order PID control strategy based on a multi-objective optimization algorithm, aiming to enhance the system’s frequency regulation, power balance, and disturbance rejection capabilities. The strategy combines the adaptive decision-making ability of fuzzy control with the high-degree-of-freedom tuning features of fractional-order PID. The multi-objective optimization algorithm AGE-MOEA-II is employed to jointly optimize five core parameters of the fuzzy fractional-order PID controller (Kp, Ki, Kd, λ, and μ), balancing multiple objectives such as system dynamic response speed, steady-state accuracy, suppression of wind–solar fluctuations, and hydropower regulation cost. Simulation results show that compared to traditional PID, single fractional-order PID, or fuzzy PID controllers, the proposed method significantly reduces system frequency deviation by 35.6%, decreases power overshoot by 42.1%, and improves renewable energy utilization by 17.3%. This provides an effective and adaptive solution for the stable operation of hydro–wind–solar–storage systems under uncertain and variable conditions.