A. E. Lisova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
A. E. Lisova has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- A. A. Agafonova
GENERIUM JSC
2 shared publications - Alexander A. Kazarov
GENERIUM JSC
2 shared publications - Ivan V. Lyagoskin
GENERIUM JSC
2 shared publications - I. M. Alaeva
GENERIUM JSC
1 shared publication - Ivan V. Shevchenko
FGBI “Federal Centre for Animal Health” (FGBI “ARRIAH”)
1 shared publication - Ivan Yu. Zhukov
FGBI “ARRIAH
1 shared publication
Latest Publications
- Open Access
- 29 September 2025
- Published by SCEEMP in Biological Products. Prevention, Diagnosis, Treatment
- Vol. 25 (3) , 271-283
Validation of a biolayer interferometry-based method for the determination of binding (total) antibodies to romiplostim in human serum
INTRODUCTION. Romiplostim treatment of patients with idiopathic thrombocytopenic purpura is associated with formation of anti-drug antibodies (ADA), which often leads to the serious adverse events. A method based on biolayer interferometry is proposed for determination of binding (total) ADA (bADA) to romiplostim in human serum. From a technological point of view, instruments using this principle have some advantages (higher throughput, prolonged service intervals, low level of equipment contamination during analysis of biosamples) over those based on surface plasmon resonance, which are used to monitor bADA levels during clinical trials of the original drug. The method should be validated to ensure reproducibility of measurements and standardise clinical laboratory trials of the immunogenicity of a biosimilar drug.AIM. To establish the key validation characteristics of a biolayer interferometry-based method for the determination of total anti-drug antibodies to romiplostim in human serum.MATERIALS AND METHODS. The method is used to detect the specific interaction of binding antibodies with biotinylated romiplostim immobilised on the streptavidin-coated biosensors. The method includes a screening test to determine bADA presence or absence in the samples; a confirmatory test to check the specificity of bADA binding to romiplostim; determination of antibody titer and maximal dilution, that allows to detect bADA in the samples. Positive control samples containing different concentrations of polyclonal rabbit antibodies to romiplostim were used in the work. Detection of protein complex formation was performed in real time mode using an Octet® QKe interferometer.RESULTS. The biological variability factor and the limit of not significant inhibition were 1.481 and 34.2%, respectively. The precision and specificity of the method were confirmed. The lower limit of bADA detection in the absence of romiplostim was 622 ng/mL. The analytical signal of 8 out of 10 blood serum samples after the addition of bADA increased by more than 1.481 times when assessing the matrix effect in the screening test; the percentage inhibition value exceeded 34.2% when analysing 8 out of 10 samples with the addition of bADA in the confirmatory test. There was no high-dose effect at bADA concentrations from 0.8 to 50 μg/mL. The results of bADA determination in the screening test were robust to the presence of 1 ng/mL romiplostim in the samples. Streptavidin-coated biosensors with immobilised romiplostim maintained stability after 14 days of storage at a temperature of (5±3) °С and at least 20 regeneration cycles.CONCLUSIONS. Analysis of the validation results obtained confirms the suitability of the method for reliable and reproducible determination of binding (total) antibodies to romiplostim in human serum.
- 29 September 2025
- Published by SCEEMP in Biological Products. Prevention, Diagnosis, Treatment
- Vol. 25 (3) , 271-283
Open AccessValidation of a biolayer interferometry-based method for the determination of binding (total) antibodies to romiplostim in human serum
INTRODUCTION. Romiplostim treatment of patients with idiopathic thrombocytopenic purpura is associated with formation of anti-drug antibodies (ADA), which often leads to the serious adverse events. A method based on biolayer interferometry is proposed for determination of binding (total) ADA (bADA) to romiplostim in human serum. From a technological point of view, instruments using this principle have some advantages (higher throughput, prolonged service intervals, low level of equipment contamination during analysis of biosamples) over those based on surface plasmon resonance, which are used to monitor bADA levels during clinical trials of the original drug. The method should be validated to ensure reproducibility of measurements and standardise clinical laboratory trials of the immunogenicity of a biosimilar drug.AIM. To establish the key validation characteristics of a biolayer interferometry-based method for the determination of total anti-drug antibodies to romiplostim in human serum.MATERIALS AND METHODS. The method is used to detect the specific interaction of binding antibodies with biotinylated romiplostim immobilised on the streptavidin-coated biosensors. The method includes a screening test to determine bADA presence or absence in the samples; a confirmatory test to check the specificity of bADA binding to romiplostim; determination of antibody titer and maximal dilution, that allows to detect bADA in the samples. Positive control samples containing different concentrations of polyclonal rabbit antibodies to romiplostim were used in the work. Detection of protein complex formation was performed in real time mode using an Octet® QKe interferometer.RESULTS. The biological variability factor and the limit of not significant inhibition were 1.481 and 34.2%, respectively. The precision and specificity of the method were confirmed. The lower limit of bADA detection in the absence of romiplostim was 622 ng/mL. The analytical signal of 8 out of 10 blood serum samples after the addition of bADA increased by more than 1.481 times when assessing the matrix effect in the screening test; the percentage inhibition value exceeded 34.2% when analysing 8 out of 10 samples with the addition of bADA in the confirmatory test. There was no high-dose effect at bADA concentrations from 0.8 to 50 μg/mL. The results of bADA determination in the screening test were robust to the presence of 1 ng/mL romiplostim in the samples. Streptavidin-coated biosensors with immobilised romiplostim maintained stability after 14 days of storage at a temperature of (5±3) °С and at least 20 regeneration cycles.CONCLUSIONS. Analysis of the validation results obtained confirms the suitability of the method for reliable and reproducible determination of binding (total) antibodies to romiplostim in human serum.
- Open Access
- 29 September 2025
- Published by SCEEMP in Biological Products. Prevention, Diagnosis, Treatment
- Vol. 25 (3) , 284-295
Detection of anti-drug antibodies to aflibercept by enzyme-linked immunosorbent assay: Development and validation of the method
INTRODUCTION. Aflibercept is used to treat neovascular age-related macular degeneration, a leading cause of vision loss. Immunogenicity is one of the significant adverse effects that results in the production of anti-drug antibodies (ADAs). The development of a method for detecting ADAs to aflibercept is essential for immunogenicity assessment.AIM. This study aimed to develop and validate an analytical method for detection and stepwise characterisation of total anti-drug antibodies to aflibercept in human serum utilising the enzyme-linked immunosorbent assay.MATERIALS AND METHODS. The method was developed using a solid-phase ELISA. Aflibercept (GNR-098, JSC GENERIUM, Russia) and a conjugate of GNR-098 with horseradish peroxidase were employed. Polyclonal antibodies against GNR-098 were obtained by immunising rats, followed by serum collection and antibody purification via affinity chromatography. ADA detection was performed using labelled GNR-098 in a bridging ELISA. Model samples were prepared by spiking pooled sera from healthy donors with rat polyclonal antibodies. Method validation included the following parameters: cut-off points; precision; limit of detection (LOD); drug tolerance; specificity; matrix effect; minimum required dilution; robustness; reagent stability; hook effect.RESULTS. An analytical method includes a screening assay for the presumptive detection of ADAs; a confirmatory assay to establish ADA specificity and assay for ADA titer determination and IgE isotyping. The cut-off points for the screening assay and IgE-specific assay were 1.3 and 1.2, respectively; for the confirmatory assay, 15.2%. The LOD of the screening assay was 185 ng/mL. The method demonstrated drug tolerance (interference from soluble target, hrVEGF165) at concentrations up to 2,000 pg/mL. No matrix effects were observed in the screening or confirmatory assays across 13 test samples containing ADAs at 280 ng/mL. The absence of a hook effect was confirmed in both assays using samples with ADA concentrations five times higher than the high-positive control.CONCLUSIONS. An analytical method was developed for the ELISA-based detection and stepwise characterisation of total anti-drug antibodies to aflibercept (GNR-098) in human serum. The method’s suitability was confirmed through validation. This analytical procedure will facilitate the immunogenicity assessment of aflibercept.
- 29 September 2025
- Published by SCEEMP in Biological Products. Prevention, Diagnosis, Treatment
- Vol. 25 (3) , 284-295
Open AccessDetection of anti-drug antibodies to aflibercept by enzyme-linked immunosorbent assay: Development and validation of the method
INTRODUCTION. Aflibercept is used to treat neovascular age-related macular degeneration, a leading cause of vision loss. Immunogenicity is one of the significant adverse effects that results in the production of anti-drug antibodies (ADAs). The development of a method for detecting ADAs to aflibercept is essential for immunogenicity assessment.AIM. This study aimed to develop and validate an analytical method for detection and stepwise characterisation of total anti-drug antibodies to aflibercept in human serum utilising the enzyme-linked immunosorbent assay.MATERIALS AND METHODS. The method was developed using a solid-phase ELISA. Aflibercept (GNR-098, JSC GENERIUM, Russia) and a conjugate of GNR-098 with horseradish peroxidase were employed. Polyclonal antibodies against GNR-098 were obtained by immunising rats, followed by serum collection and antibody purification via affinity chromatography. ADA detection was performed using labelled GNR-098 in a bridging ELISA. Model samples were prepared by spiking pooled sera from healthy donors with rat polyclonal antibodies. Method validation included the following parameters: cut-off points; precision; limit of detection (LOD); drug tolerance; specificity; matrix effect; minimum required dilution; robustness; reagent stability; hook effect.RESULTS. An analytical method includes a screening assay for the presumptive detection of ADAs; a confirmatory assay to establish ADA specificity and assay for ADA titer determination and IgE isotyping. The cut-off points for the screening assay and IgE-specific assay were 1.3 and 1.2, respectively; for the confirmatory assay, 15.2%. The LOD of the screening assay was 185 ng/mL. The method demonstrated drug tolerance (interference from soluble target, hrVEGF165) at concentrations up to 2,000 pg/mL. No matrix effects were observed in the screening or confirmatory assays across 13 test samples containing ADAs at 280 ng/mL. The absence of a hook effect was confirmed in both assays using samples with ADA concentrations five times higher than the high-positive control.CONCLUSIONS. An analytical method was developed for the ELISA-based detection and stepwise characterisation of total anti-drug antibodies to aflibercept (GNR-098) in human serum. The method’s suitability was confirmed through validation. This analytical procedure will facilitate the immunogenicity assessment of aflibercept.