Sangjoon Jonathan Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Sangjoon Jonathan Kim has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Jung Kim
Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
6 shared publications - Jose Luis Pons
Shirley Ryan AbilityLab, Chicago, IL, USA
5 shared publications - Yue Wen
Department of Mechanical and Aerospace Engineering at the University of Central Florida, FL, USA
5 shared publications - Emek Barış Küçüktabak
Shirley Ryan AbilityLab, Chicago, IL, USA
3 shared publications - Junghoon Park
Baruch College & The Graduate Center, CUNY
3 shared publications - Kevin M. Lynch
Center for Robotics and Biosystems, Northwestern University, Evanston, IL, USA
3 shared publications
Latest Publications
- Open Access
- 11 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 2438-2446
Forecasting Dropout in Home-Based Movement Rehabilitation After Stroke With Sensors and Machine Learning
Adherence to home-based rehabilitation can support recovery after stroke, yet many patients disengage within the first few weeks. While prior studies have examined perseverance in small samples or under supervised settings, little is known about early behavioral signals of long-term perseverance in large, unsupervised cohorts. This study analyzes one of the largest datasets on home rehabilitation perseverance measured with a sensorized system (N = 2,747 FitMi users) and applies interpretable machine learning models to forecast dropout risk. We focused on generalizable features (features that are readily available in many other home exercise systems). As a starting point for analysis, we used the first three weeks of exercise behavior to predict persistence into the fourth week, the highest-performing model achieved an AUC of 0.810, indicating strong separability between persisters and non-persisters. The precision–recall trade-off was also strong, with prAUC = 0.717, and F1-score = 0.703. For this model, feature importance analysis identified average weekly active days (24.7%), exercise consistency (16.4%), average selected session length (15.2%), and repetition rate (10.1%) as the most predictive behavioral signals. These findings demonstrate that early engagement patterns, which are easily measurable with a wide range of sensor-based systems, contain robust information for identifying users at risk of stopping home movement practice. Such identification could provide a scalable pathway for adaptive, personalized interventions in autonomous rehabilitation systems.
- 11 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 2438-2446
Open AccessForecasting Dropout in Home-Based Movement Rehabilitation After Stroke With Sensors and Machine Learning
Adherence to home-based rehabilitation can support recovery after stroke, yet many patients disengage within the first few weeks. While prior studies have examined perseverance in small samples or under supervised settings, little is known about early behavioral signals of long-term perseverance in large, unsupervised cohorts. This study analyzes one of the largest datasets on home rehabilitation perseverance measured with a sensorized system (N = 2,747 FitMi users) and applies interpretable machine learning models to forecast dropout risk. We focused on generalizable features (features that are readily available in many other home exercise systems). As a starting point for analysis, we used the first three weeks of exercise behavior to predict persistence into the fourth week, the highest-performing model achieved an AUC of 0.810, indicating strong separability between persisters and non-persisters. The precision–recall trade-off was also strong, with prAUC = 0.717, and F1-score = 0.703. For this model, feature importance analysis identified average weekly active days (24.7%), exercise consistency (16.4%), average selected session length (15.2%), and repetition rate (10.1%) as the most predictive behavioral signals. These findings demonstrate that early engagement patterns, which are easily measurable with a wide range of sensor-based systems, contain robust information for identifying users at risk of stopping home movement practice. Such identification could provide a scalable pathway for adaptive, personalized interventions in autonomous rehabilitation systems.
- Top Cited PapersOpen Access
- 29 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 40 (15523098) , 1842-1859
Haptic Transparency and Interaction Force Control for a Lower Limb Exoskeleton
Controlling the interaction forces between a human and an exoskeleton is crucial for providing transparency or adjusting assistance or resistance levels. However, it is an open problem to control the interaction forces of lower-limb exoskeletons designed for unrestricted overground walking. For these types of exoskeletons, it is challenging to implement force/torque sensors at every contact between the user and the exoskeleton for direct force measurement. Moreover, it is important to compensate for the exoskeleton's whole-body gravitational and dynamical forces, especially for heavy lower-limb exoskeletons. Previous works either simplified the dynamic model by treating the legs as independent double pendulums, or they did not close the loop with interaction force feedback. The proposed whole-exoskeleton closed-loop compensation (WECC) method calculates the interaction torques during the complete gait cycle by using whole-body dynamics and joint torque measurements on a hip-knee exoskeleton. Furthermore, it uses a constrained optimization scheme to track desired interaction torques in a closed loop while considering physical and safety constraints. We evaluated the haptic transparency and dynamic interaction torque tracking of WECC control on three subjects. We also compared the performance of WECC with a controller based on a simplified dynamic model and a passive version of the exoskeleton. The WECC controller results in a consistently low absolute interaction torque error during the whole gait cycle for both zero and nonzero desired interaction torques. In contrast, the simplified controller yields poor performance in tracking desired interaction torques during the stance phase
- 29 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 40 (15523098) , 1842-1859
Top Cited PapersOpen AccessHaptic Transparency and Interaction Force Control for a Lower Limb Exoskeleton
Controlling the interaction forces between a human and an exoskeleton is crucial for providing transparency or adjusting assistance or resistance levels. However, it is an open problem to control the interaction forces of lower-limb exoskeletons designed for unrestricted overground walking. For these types of exoskeletons, it is challenging to implement force/torque sensors at every contact between the user and the exoskeleton for direct force measurement. Moreover, it is important to compensate for the exoskeleton's whole-body gravitational and dynamical forces, especially for heavy lower-limb exoskeletons. Previous works either simplified the dynamic model by treating the legs as independent double pendulums, or they did not close the loop with interaction force feedback. The proposed whole-exoskeleton closed-loop compensation (WECC) method calculates the interaction torques during the complete gait cycle by using whole-body dynamics and joint torque measurements on a hip-knee exoskeleton. Furthermore, it uses a constrained optimization scheme to track desired interaction torques in a closed loop while considering physical and safety constraints. We evaluated the haptic transparency and dynamic interaction torque tracking of WECC control on three subjects. We also compared the performance of WECC with a controller based on a simplified dynamic model and a passive version of the exoskeleton. The WECC controller results in a consistently low absolute interaction torque error during the whole gait cycle for both zero and nonzero desired interaction torques. In contrast, the simplified controller yields poor performance in tracking desired interaction torques during the stance phase
- Open Access
- 18 January 2023
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 20 (1) , 016006
Toward a generalizable deep CNN for neural drive estimation across muscles and participants
Objective. High-density electromyography (HD-EMG) decomposition algorithms are used to identify individual motor unit (MU) spike trains, which collectively constitute the neural code of movements, to predict motor intent. This approach has advanced from offline to online decomposition, from isometric to dynamic contractions, leading to a wide range of neural-machine interface applications. However, current online methods need offline retraining when applied to the same muscle on a different day or to a different person, which limits their applications in a real-time neural-machine interface. We proposed a deep convolutional neural network (CNN) framework for neural drive estimation, which takes in frames of HD-EMG signals as input, extracts general spatiotemporal properties of MU action potentials, and outputs the number of spikes in each frame. The deep CNN can generalize its application without retraining to HD-EMG data recorded in separate sessions, muscles, or participants. Approach. We recorded HD-EMG signals from the vastus medialis and vastus lateralis muscles from five participants while they performed isometric contractions during two sessions separated by ∼20 months. We identified MU spike trains from HD-EMG signals using a convolutive blind source separation (BSS) method, and then used the cumulative spike train (CST) of these MUs and the HD-EMG signals to train and validate the deep CNN. Main results. On average, the correlation coefficients between CST from the BSS and that from deep CNN were 0.983 ± 0.006 for leave-one-out across-sessions-and-muscles validation and 0.989 ± 0.002 for leave-one-out across-participants validation. When trained with more than four datasets, the performance of deep CNN saturated at 0.984 ± 0.001 for cross validations across muscles, sessions, and participants. Significance. We can conclude that the deep CNN is generalizable across the aforementioned conditions without retraining. We could potentially generate a robust deep CNN to estimate neural drive to muscles for neural-machine interfaces.
- 18 January 2023
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 20 (1) , 016006
Open AccessToward a generalizable deep CNN for neural drive estimation across muscles and participants
Objective. High-density electromyography (HD-EMG) decomposition algorithms are used to identify individual motor unit (MU) spike trains, which collectively constitute the neural code of movements, to predict motor intent. This approach has advanced from offline to online decomposition, from isometric to dynamic contractions, leading to a wide range of neural-machine interface applications. However, current online methods need offline retraining when applied to the same muscle on a different day or to a different person, which limits their applications in a real-time neural-machine interface. We proposed a deep convolutional neural network (CNN) framework for neural drive estimation, which takes in frames of HD-EMG signals as input, extracts general spatiotemporal properties of MU action potentials, and outputs the number of spikes in each frame. The deep CNN can generalize its application without retraining to HD-EMG data recorded in separate sessions, muscles, or participants. Approach. We recorded HD-EMG signals from the vastus medialis and vastus lateralis muscles from five participants while they performed isometric contractions during two sessions separated by ∼20 months. We identified MU spike trains from HD-EMG signals using a convolutive blind source separation (BSS) method, and then used the cumulative spike train (CST) of these MUs and the HD-EMG signals to train and validate the deep CNN. Main results. On average, the correlation coefficients between CST from the BSS and that from deep CNN were 0.983 ± 0.006 for leave-one-out across-sessions-and-muscles validation and 0.989 ± 0.002 for leave-one-out across-participants validation. When trained with more than four datasets, the performance of deep CNN saturated at 0.984 ± 0.001 for cross validations across muscles, sessions, and participants. Significance. We can conclude that the deep CNN is generalizable across the aforementioned conditions without retraining. We could potentially generate a robust deep CNN to estimate neural drive to muscles for neural-machine interfaces.
- Open Access
- 30 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 416-425
Effect of Dyadic Haptic Collaboration on Ankle Motor Learning and Task Performance
Optimizing skill acquisition during novel motor tasks and regaining lost motor functions have been the interest of many researchers over the past few decades. One approach shown to accelerate motor learning involves haptically coupling two individuals through robotic interfaces. Studies have shown that an individual’s solo performance during upper-limb tracking tasks may improve after haptically-coupled training with a partner. In this study, our goal was to investigate whether these findings can be translated to lower-limb motor tasks, more specifically, during an ankle position tracking task. Using one-degree-of-freedom ankle movements, pairs of participants (i.e., dyads) tracked target trajectories independently. Participants alternated between tracking trials with and without haptic coupling, achieved by rendering a virtual spring between two ankle rehabilitation robots. In our analysis, we compared changes in task performance across trials while training with and without haptic coupling. The tracking performance of both individuals (i.e., dyadic task performance) improved during haptic coupling, which was likely due to averaging of random errors of the dyadic pair during tracking. However, we found that dyadic haptic coupling did not lead to faster individual learning for the tracking task. These results suggest that haptic coupling between unimpaired individuals may not be an effective method of training ankle movements during a simple, one-degree-of-freedom task.
- 30 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 416-425
Open AccessEffect of Dyadic Haptic Collaboration on Ankle Motor Learning and Task Performance
Optimizing skill acquisition during novel motor tasks and regaining lost motor functions have been the interest of many researchers over the past few decades. One approach shown to accelerate motor learning involves haptically coupling two individuals through robotic interfaces. Studies have shown that an individual’s solo performance during upper-limb tracking tasks may improve after haptically-coupled training with a partner. In this study, our goal was to investigate whether these findings can be translated to lower-limb motor tasks, more specifically, during an ankle position tracking task. Using one-degree-of-freedom ankle movements, pairs of participants (i.e., dyads) tracked target trajectories independently. Participants alternated between tracking trials with and without haptic coupling, achieved by rendering a virtual spring between two ankle rehabilitation robots. In our analysis, we compared changes in task performance across trials while training with and without haptic coupling. The tracking performance of both individuals (i.e., dyadic task performance) improved during haptic coupling, which was likely due to averaging of random errors of the dyadic pair during tracking. However, we found that dyadic haptic coupling did not lead to faster individual learning for the tracking task. These results suggest that haptic coupling between unimpaired individuals may not be an effective method of training ankle movements during a simple, one-degree-of-freedom task.
- Open Access
- 4 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 30 (15344320) , 2175-2185
sEMG-Triggered Fast Assistance Strategy for a Pneumatic Back Support Exoskeleton
To prevent lower back pain (LBP) in the industrial workplace, various powered back support exoskeletons (BSEs) have been developed. However, conventional kinematics-triggered assistance (KA) strategies induce latency, degrading assistance efficiency. Therefore, we proposed and experimentally evaluated a surface electromyography (sEMG)-triggered assistance (EA) strategy. Nine healthy subjects participated in the lifting experiments: 1) external loads test, 2) extra latency test, and 3) repetitive lifting test. In the external loads test, subject performed lifting with four different external loads (0 kg, 7.5 kg, 15 kg, and 22.5 kg). The assistance was triggered earlier by EA compared to KA from 114 ms to 202 ms, 163 ms to 269 ms for squat and stoop lifting respectively, as external loads increased from 0 kg to 22.5 kg. In the extra latency test, the effects of extra latency (manual switch, 0 ms, 100 ms and 200 ms) in EA on muscle activities were investigated. Muscle activities were minimized in the fast assistance (0 ms and 100 ms) condition and increased with extra latency. In the repetitive lifting test, the EA strategy significantly reduced L1 muscle fatigue by 70.4% in stoop lifting, compared to KA strategy. Based on the experimental results, we concluded that fast assistance triggered by sEMG improved assistance efficiency in BSE and was particularly beneficial in heavy external loads situations. The proposed assistive strategy can be used to prevent LBP by reducing back muscle fatigue and is easily applicable to various industrial exoskeleton applications.
- 4 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 30 (15344320) , 2175-2185
Open AccesssEMG-Triggered Fast Assistance Strategy for a Pneumatic Back Support Exoskeleton
To prevent lower back pain (LBP) in the industrial workplace, various powered back support exoskeletons (BSEs) have been developed. However, conventional kinematics-triggered assistance (KA) strategies induce latency, degrading assistance efficiency. Therefore, we proposed and experimentally evaluated a surface electromyography (sEMG)-triggered assistance (EA) strategy. Nine healthy subjects participated in the lifting experiments: 1) external loads test, 2) extra latency test, and 3) repetitive lifting test. In the external loads test, subject performed lifting with four different external loads (0 kg, 7.5 kg, 15 kg, and 22.5 kg). The assistance was triggered earlier by EA compared to KA from 114 ms to 202 ms, 163 ms to 269 ms for squat and stoop lifting respectively, as external loads increased from 0 kg to 22.5 kg. In the extra latency test, the effects of extra latency (manual switch, 0 ms, 100 ms and 200 ms) in EA on muscle activities were investigated. Muscle activities were minimized in the fast assistance (0 ms and 100 ms) condition and increased with extra latency. In the repetitive lifting test, the EA strategy significantly reduced L1 muscle fatigue by 70.4% in stoop lifting, compared to KA strategy. Based on the experimental results, we concluded that fast assistance triggered by sEMG improved assistance efficiency in BSE and was particularly beneficial in heavy external loads situations. The proposed assistive strategy can be used to prevent LBP by reducing back muscle fatigue and is easily applicable to various industrial exoskeleton applications.
- 24 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (4) , 6876-6883
A Framework for Dyadic Physical Interaction Studies During Ankle Motor Tasks
Over the past few decades, there have been many studies of human-human physical interaction to better understand why humans physically interact so effectively and how dyads outperform individuals in certain motor tasks. Because of the different methodologies and experimental setups in these studies, however, it is difficult to draw general conclusions as to the reasons for this improved performance. In this study, we propose an open-source experimental system for the systematic study of the effect of human-human interaction, as mediated by robots, at the ankle joint. We also propose a new framework to study various interactive behaviors (i.e., collaborative, cooperative, and competitive tasks) that can be emulated using a virtual spring connecting human pairs. To validate the proposed experimental framework, we perform a transparency analysis, which is closely related to haptic rendering performance. We compare muscle EMG and ankle motion data while subjects are barefoot, attached to the unpowered robot, and attached to the powered robot implementing transparency control. We also validate the performance in rendering virtual springs covering a range of stiffness values (5-50 Nm/rad) while the subjects track several desired trajectories (sine waves at frequencies between 0.1 and 1.1 Hz). Finally, we demonstrate the feasibility of the system in studying human-human interaction under different interactive behaviors.
- 24 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (4) , 6876-6883
A Framework for Dyadic Physical Interaction Studies During Ankle Motor Tasks
Over the past few decades, there have been many studies of human-human physical interaction to better understand why humans physically interact so effectively and how dyads outperform individuals in certain motor tasks. Because of the different methodologies and experimental setups in these studies, however, it is difficult to draw general conclusions as to the reasons for this improved performance. In this study, we propose an open-source experimental system for the systematic study of the effect of human-human interaction, as mediated by robots, at the ankle joint. We also propose a new framework to study various interactive behaviors (i.e., collaborative, cooperative, and competitive tasks) that can be emulated using a virtual spring connecting human pairs. To validate the proposed experimental framework, we perform a transparency analysis, which is closely related to haptic rendering performance. We compare muscle EMG and ankle motion data while subjects are barefoot, attached to the unpowered robot, and attached to the powered robot implementing transparency control. We also validate the performance in rendering virtual springs covering a range of stiffness values (5-50 Nm/rad) while the subjects track several desired trajectories (sine waves at frequencies between 0.1 and 1.1 Hz). Finally, we demonstrate the feasibility of the system in studying human-human interaction under different interactive behaviors.
- Open Access
- 6 April 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (5) , 056003
A convolutional neural network to identify motor units from high-density surface electromyography signals in real time
Objectives. This paper aims to investigate the feasibility and the validity of applying deep convolutional neural networks (CNN) to identify motor unit (MU) spike trains and estimate the neural drive to muscles from high-density electromyography (HD-EMG) signals in real time. Two distinct deep CNNs are compared with the convolution kernel compensation (CKC) algorithm using simulated and experimentally recorded signals. The effects of window size and step size of the input HD-EMG signals are also investigated. Approach. The MU spike trains were first identified with the CKC algorithm. The HD-EMG signals and spike trains were used to train the deep CNN. Then, the deep CNN decomposed the HD-EMG signals into MU discharge times in real time. Two CNN approaches are compared with the CKC: (a) multiple single-output deep CNN (SO-DCNN) with one MU decomposed per network, and (b) one multiple-output deep CNN (MO-DCNN) to decompose all MUs (up to 23) with one network. Main results. The MO-DCNN outperformed the SO-DCNN in terms of training time (3.2–21.4 s epoch−1 vs 6.5–47.8 s epoch−1, respectively) and prediction time (0.04 vs 0.27 s sample−1, respectively). The optimal window size and step size for MO-DCNN were 120 and 20 data points, respectively. It results in sensitivity of 98% and 85% with simulated and experimentally recorded HD-EMG signals, respectively. There is a high cross-correlation coefficient between the neural drive estimated with CKC and that estimated with MO-DCNN (range of r-value across conditions: 0.88–0.95). Significance. We demonstrate the feasibility and the validity of using deep CNN to accurately identify MU activity from HD-EMG with a latency lower than 80 ms, which falls within the lower bound of the human electromechanical delay. This method opens many opportunities for using the neural drive to interface humans with assistive devices.
- 6 April 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (5) , 056003
Open AccessA convolutional neural network to identify motor units from high-density surface electromyography signals in real time
Objectives. This paper aims to investigate the feasibility and the validity of applying deep convolutional neural networks (CNN) to identify motor unit (MU) spike trains and estimate the neural drive to muscles from high-density electromyography (HD-EMG) signals in real time. Two distinct deep CNNs are compared with the convolution kernel compensation (CKC) algorithm using simulated and experimentally recorded signals. The effects of window size and step size of the input HD-EMG signals are also investigated. Approach. The MU spike trains were first identified with the CKC algorithm. The HD-EMG signals and spike trains were used to train the deep CNN. Then, the deep CNN decomposed the HD-EMG signals into MU discharge times in real time. Two CNN approaches are compared with the CKC: (a) multiple single-output deep CNN (SO-DCNN) with one MU decomposed per network, and (b) one multiple-output deep CNN (MO-DCNN) to decompose all MUs (up to 23) with one network. Main results. The MO-DCNN outperformed the SO-DCNN in terms of training time (3.2–21.4 s epoch−1 vs 6.5–47.8 s epoch−1, respectively) and prediction time (0.04 vs 0.27 s sample−1, respectively). The optimal window size and step size for MO-DCNN were 120 and 20 data points, respectively. It results in sensitivity of 98% and 85% with simulated and experimentally recorded HD-EMG signals, respectively. There is a high cross-correlation coefficient between the neural drive estimated with CKC and that estimated with MO-DCNN (range of r-value across conditions: 0.88–0.95). Significance. We demonstrate the feasibility and the validity of using deep CNN to accurately identify MU activity from HD-EMG with a latency lower than 80 ms, which falls within the lower bound of the human electromechanical delay. This method opens many opportunities for using the neural drive to interface humans with assistive devices.
- 26 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 5 (3) , 3799-3805
Design of an Inflatable Wrinkle Actuator With Fast Inflation/Deflation Responses for Wearable Suits
In recent years, inflatable actuators have been widely used in wearable suits to assist humans who need help in moving their joints. Despite their lightweight and simple structure, they have long inflation and deflation times, which make their quick use difficult. To resolve this issue, we propose an inflatable wrinkle actuator with fast inflation and deflation responses. First, a theoretical model is proposed to develop an actuator that satisfies the design requirements: the desired assistive torque and the foam factor based on the wearability. Second, we reduce the inflation and deflation times by partially controlling the actuator layers and by designing pneumatic circuits using a vacuum ejector. To validate the usability of the actuator in wearable suits, we applied it to a wearable knee suit, and the inflation and deflation times were 0.40 s and 0.16 s, respectively. As a result, we ensured that the actuator did not interfere with human knee joint movement during walking by creating any residual resistance.
- 26 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 5 (3) , 3799-3805
Design of an Inflatable Wrinkle Actuator With Fast Inflation/Deflation Responses for Wearable Suits
In recent years, inflatable actuators have been widely used in wearable suits to assist humans who need help in moving their joints. Despite their lightweight and simple structure, they have long inflation and deflation times, which make their quick use difficult. To resolve this issue, we propose an inflatable wrinkle actuator with fast inflation and deflation responses. First, a theoretical model is proposed to develop an actuator that satisfies the design requirements: the desired assistive torque and the foam factor based on the wearability. Second, we reduce the inflation and deflation times by partially controlling the actuator layers and by designing pneumatic circuits using a vacuum ejector. To validate the usability of the actuator in wearable suits, we applied it to a wearable knee suit, and the inflation and deflation times were 0.40 s and 0.16 s, respectively. As a result, we ensured that the actuator did not interfere with human knee joint movement during walking by creating any residual resistance.
- 24 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 5 (2) , 2047-2053
Backdrivable and Fully-Portable Pneumatic Back Support Exoskeleton for Lifting Assistance
- 24 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 5 (2) , 2047-2053
Backdrivable and Fully-Portable Pneumatic Back Support Exoskeleton for Lifting Assistance
- 21 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 25 (1) , 66-75
Wireless Ground Reaction Force Sensing System Using a Mechanically Decoupled Two-Dimensional Force Sensor
- 21 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 25 (1) , 66-75
Wireless Ground Reaction Force Sensing System Using a Mechanically Decoupled Two-Dimensional Force Sensor