JYJianhua Yang

Jianhua Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jianhua Yang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Zhijuan Zhao

    Key Laboratory of Special Equipment Safety and Energy-saving for State Market Regulation, China Special Equipment Inspection & Research Institute, Beijing 100029, China

    2 shared publications
  • Dexin Kong

    Key Laboratory of Special Equipment Safety and Energy-saving for State Market Regulation, China Special Equipment Inspection & Research Institute, Beijing 100029, China

    1 shared publication
  • Dong Jin

    Key Laboratory of Special Equipment Safety and Energy-saving for State Market Regulation, China Special Equipment Inspection & Research Institute, Beijing 100029, China

    1 shared publication
  • Qiang Dai

    Key Laboratory of Special Equipment Safety and Energy-saving for State Market Regulation, China Special Equipment Inspection & Research Institute, Beijing 100029, China

    1 shared publication
  • Shichun Feng

    Key Laboratory of Special Equipment Safety and Energy-saving for State Market Regulation, China Special Equipment Inspection & Research Institute, Beijing 100029, China

    1 shared publication
  • Yunyan Peng

    Key Laboratory of Special Equipment Safety and Energy-saving for State Market Regulation, China Special Equipment Inspection & Research Institute, Beijing 100029, China

    1 shared publication

Latest Publications

  • Open Access

    Effects of Surface Modification on the Electrodialysis Performance of Anion-Exchange Membranes

    by Zhijuan Zhao, Qiang Dai, Shichun Feng, Jianhua Yang

    A commercial anion-exchange membrane was modified via the electrodeposition of different water-soluble polymers to study the effects of surface modification on electrodialysis performance. X-ray photoelectron spectroscopy and attenuated total reflectance Fourier transform infrared spectroscopy analyses showed that the different polymers were successfully electrodeposited on the membrane surface. The surface morphology and electrical resistance of the modified AEMs were almost unchanged. Contact angle and zeta potential measurements indicated differences in the surface hydrophilicity and surface charge density of the modified AEMs. The electrodialysis performance of the pristine AEM declined significantly in the presence of the foulant. In contrast, the electrodialysis performance of the AEMs modified with poly (vinylsulfonic acid, sodium salt) showed almost no decline and exhibited the best antifouling property in the presence of the foulant, followed by those modified with poly (sodium acrylate) and poly (vinyl alcohol). The results indicated that an increase in surface negative charge density and surface hydrophilicity increased the resistance of the modified AEMs to the foulant and improved their electrodialysis performance.


  • Open Access

    Effects of Operational Parameters on Mg2+/Li+ Separation Performance in Electrodialysis System

    by Zhijuan Zhao, Jianhua Yang, Dexin Kong, Yunyan Peng, Dong Jin

    Brine with a high magnesium-to-lithium ratio was separated by electrodialysis equipped with a monovalent cation exchange membrane under differing operational parameters. The ionic concentration variations, separation coefficients, lithium recovery ratio, permselectivity coefficient, and Li+ flux were analyzed to evaluate the effect of the initial Li+/Mg2+ mass concentration ratio, applied voltage, and initial volume ratio between the dilute and concentrated compartments on the separation performance of magnesium and lithium. The results showed that the increase in initial Li+/Mg2+ concentration ratio significantly increased the separation coefficient, lithium recovery ratio, and Li+ flux, demonstrating an improvement in the separation performance since the Li+ migration was accelerated when less Mg2+ competed with Li+. As the applied voltage increased from 10 V to 15 V, the separation coefficient increased, and the lithium recovery ratio and Li+ flux increased within 60 min; however, as the applied voltage increased to 20 V, the separation coefficient, the lithium recovery ratio, and the Li+ flux did not increase, which indicated that an increase in the applied voltage within the limits would contribute to the separation performance. The increase in the initial volume ratio between the dilute and concentrated compartments decreased the separation coefficient and lithium recovery ratio, indicating that the separation performance had declined.