Hassan Al Kanti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hassan Al Kanti has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Maged Mohammed
Abdelmalek Essaadi Universit , Faculty of Sciences , Tetouan , Morocco
2 shared publications- Otman El Hajjaji
Radiations and Nuclear Systems Laboratory, University Abdelmalek Essaadi, Faculty of Sciences, Tetouan, Morocco
2 shared publications - Tarek EL Bardouni
Radiations and Nuclear Systems Laboratory, Faculty of Sciences, Abdelmalek Essaadi University, Tetouan, Morocco
2 shared publications A. Arectout
1 shared publicationMurad Al Mugahed
1 shared publicationO. El Hajjaji
1 shared publication
Latest Publications
- Open Access
- 1 March 2022
- Published by Walter de Gruyter GmbH in Polish Journal of Medical Physics And Engineering
- Vol. 28 (1) , 52-59
Neutron conversion coefficients of ambient dose equivalent and personal dose equivalent
Introduction: This work aims to calculate the ambient and personal dose equivalent conversion coefficients. Material and methods: The conversion coefficients have been calculated using MC simulation. Additionally, this paper proposes a new method that depends on an analytical approach. Results: The obtained results in good agreement between MC and an analytical approach were observed. The obtained results were compared to those published in ICRU 57 report. Conclusions: We deduced that the analytical approach is as effective and suitable as the MC simulation to calculate the operational quantity conversion coefficients.
- 1 March 2022
- Published by Walter de Gruyter GmbH in Polish Journal of Medical Physics And Engineering
- Vol. 28 (1) , 52-59
Open AccessNeutron conversion coefficients of ambient dose equivalent and personal dose equivalent
Introduction: This work aims to calculate the ambient and personal dose equivalent conversion coefficients. Material and methods: The conversion coefficients have been calculated using MC simulation. Additionally, this paper proposes a new method that depends on an analytical approach. Results: The obtained results in good agreement between MC and an analytical approach were observed. The obtained results were compared to those published in ICRU 57 report. Conclusions: We deduced that the analytical approach is as effective and suitable as the MC simulation to calculate the operational quantity conversion coefficients.
- 1 September 2021
- Published by Allerton Press in Moscow University Physics Bulletin
- Vol. 76 (5) , 380-383
A Novel Approach for Photon Ambient Dose Equivalent Conversion Coefficients Calculation
This work aims to calculate the air Kerma to ambient dose equivalent conversion coefficients
- 1 September 2021
- Published by Allerton Press in Moscow University Physics Bulletin
- Vol. 76 (5) , 380-383
A Novel Approach for Photon Ambient Dose Equivalent Conversion Coefficients Calculation
This work aims to calculate the air Kerma to ambient dose equivalent conversion coefficients