ZZZhiruo Zhang

Zhiruo Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhiruo Zhang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Reactive Power Control Strategy for Isolated Single-Stage Three-Phase SWISS AC–DC Converter Based on Dual Active Bridge Converters

    by Zhiqiang Guo, Zhiruo Zhang, Guoen Cao

    This paper proposes a reactive power control strategy for a three-phase single-stage isolated SWISS AC-DC converter based on the dual active bridge (DAB). By analyzing the conduction states of the SWISS converter, the relationship between the input currents of the two DAB converters and the grid current in different voltage sectors is examined. A triple phase shift (TPS) control strategy is applied to ensure the DAB converter works in the globally optimal working modes, thereby achieving zero-voltage switching (ZVS) of the high-frequency switching devices and effectively reducing conduction losses. Based on TPS control, an analytical expression relating the phase shift angle and the input current of the DAB converter is derived, with the sign of the phase shift angle determined according to the polarity of the grid current in each sector, thereby enabling precise control over both the magnitude and direction of the input current. A dual-loop control strategy is proposed to achieve reactive power control on the grid side and output regulation on the load side, thereby improving the power quality of the system. The variations in the working modes and control variables under the reactive power control strategy at different load powers are analyzed, demonstrating the strategy's adaptability to a wide range of loads. In addition, the design method for the series inductor is analyzed to achieve reactive power control while meeting the load power requirements. Finally, the proposed control strategy is applied to a 1.4 kW three-phase single-stage SWISS converter based on DAB with 200V/50Hz input line voltage and 200V output voltage. The experimental results validate the feasibility and effectiveness of the proposed control strategy.

  • Reactive Power Control Strategy for Isolated Single-Stage AC–DC Converter Based on Dual Active Bridge

    by Zhiqiang Guo, Zhiruo Zhang, Bin Zhang

    This article presents a reactive power control strategy for the isolated single-stage dual active bridge (DAB) ac–dc converter. Triple phase shift (TPS) control is employed to achieve zero-voltage switching and reduce conduction losses, ensuring globally optimal working modes. The impact of the phase difference between the grid voltage and current on the input current direction of the DAB dc–dc converter is analyzed. Under TPS control, the input current direction is regulated by adjusting the polarity of the phase shift angle (i.e., positive or negative values). A control algorithm for the DAB ac–dc converter is proposed to enable reactive power control on the grid side and output regulation on the load side, thereby improving the power quality of the system. The variations in working modes concerning load power and line-frequency angle under the reactive power control strategy are investigated. Based on the control strategy for optimal working modes, the proposed method ensures that the DAB ac–dc converter operates efficiently across a wide range of load power. In addition, the design methodology of the series inductor is analyzed to achieve reactive power control while meeting target load power requirements. Finally, the proposed control strategy is applied to a 1-kW DAB ac–dc converter with a 220 V/50 Hz input voltage and a 200-V output voltage. The experimental results validate the feasibility and effectiveness of the reactive power control strategy.


  • Single-Stage Isolated Three-Phase SWISS AC–DC Converter Based on Dual Active Bridge Converters

    by Zhiqiang Guo, Zhiruo Zhang, Ge Zou

    This article proposes a single-stage three-phase ac–dc converter composed of a SWISS converter and two dual active bridge (DAB) converters connected in parallel at the output. The input current relationship between the SWISS and DAB converters is analyzed, and the optimal triple-phase-shift (TPS) control of the DAB converter is introduced to achieve the unity power factor for the entire load power. Under optimal TPS control, zero voltage switching and minimal current stress can be achieved. Based on the optimal working modes of TPS control, the analytical expression is derived to describe the relationship between the phase-shift angle and the input current of the DAB converter. A dual-loop control strategy is proposed to achieve good power quality and output regulation. The ranges of working modes and the control variables under different load power conditions are analyzed, demonstrating the adaptability of this strategy to a wide range of load powers. The design of the series inductor and the calculation of losses are discussed, and the loss distribution under different power conditions is presented. Finally, the proposed control strategy is applied to a 1.6 kW three-phase single-stage DAB-based SWISS converter with 200 V/50 Hz input line voltage and 200 V output voltage. The experimental results validate the feasibility and effectiveness of the control strategy.