Issah M. AlHamad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Issah M. AlHamad has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Hanan Taleb
Faculty of Engineering and IT, The British University in Dubai, Dubai, UAE
2 shared publications- Ali Hassan Al-Marzouqi
UAE University
1 shared publication - Essam Zaneldin
Department of Civil and Environmental Engineering, United Arab Emirates University, Al Ain P.O. Box 15551, United Arab Emirates
1 shared publication Hanan Hashaykeh
GameAbove College of Engineering and Technology, Interior Design, EMU, Ypsilanti, USA
1 shared publication- Lindita Bande
College of Engineering, UAE University
1 shared publication Moamin AlSaleem
Faculty of Engineering & IT, The British University in Dubai, Dubai, UAE
1 shared publication
Latest Publications
- Open Access
- 24 December 2025
- Published by Springer Nature in Discover Sustainability
- Vol. 7 (1)
Electric vehicle adoption in Jordan: analyzing consumer motivations and barriers
- 24 December 2025
- Published by Springer Nature in Discover Sustainability
- Vol. 7 (1)
Open AccessElectric vehicle adoption in Jordan: analyzing consumer motivations and barriers
- 31 August 2025
- Published by Springer Nature
- p. 389-405
Integrating 3D Printing Practices Within Academia
- 31 August 2025
- Published by Springer Nature
- p. 389-405
Integrating 3D Printing Practices Within Academia
- Open Access
- 1 August 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1276 (1) , 012059
Passive Heating and Cooling Potential Strategies: A Comparison between Moderate Summers and Warm Winters Climate Zones
In this work, a comparison between different potential natural ventilation strategies used in different climate zones are investigated. As an example of moderate summer climate zone, London city has been selected, while Dubai city has been selected as a warm winter climate zone. The influence of external wind speed and pressure was studied using Autodesk Flow Design Software. Then CFD simulations have been generated inside the building using IES Virtual Environment software to study the indoor ventilation (Micro-Flow analysis) and to demonstrate the success of the adopted potential strategies in enhancing the indoor climate conditions. Hourly Analysis Program (HAP) was used to calculate the cooling/heating load of the building and to check the energy savings. The results demonstrated that comfort conditions within the interior space of the building were met during certain months of the year using passive heating/cooling strategies alone (without the need of HVAC system). HAP energy modeling results showed that the annual space cooling for Dubai model dropped from almost 58,000 kW per year to almost 42,000 kW with a total energy savings of 18.6% (including all energy consumption parameters). On the other hand, London model results showed that the annual interior space heating dropped from almost 36,000 kW to almost 28,000 kW with a total energy savings of 16.4%.
- 1 August 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1276 (1) , 012059
Open AccessPassive Heating and Cooling Potential Strategies: A Comparison between Moderate Summers and Warm Winters Climate Zones
In this work, a comparison between different potential natural ventilation strategies used in different climate zones are investigated. As an example of moderate summer climate zone, London city has been selected, while Dubai city has been selected as a warm winter climate zone. The influence of external wind speed and pressure was studied using Autodesk Flow Design Software. Then CFD simulations have been generated inside the building using IES Virtual Environment software to study the indoor ventilation (Micro-Flow analysis) and to demonstrate the success of the adopted potential strategies in enhancing the indoor climate conditions. Hourly Analysis Program (HAP) was used to calculate the cooling/heating load of the building and to check the energy savings. The results demonstrated that comfort conditions within the interior space of the building were met during certain months of the year using passive heating/cooling strategies alone (without the need of HVAC system). HAP energy modeling results showed that the annual space cooling for Dubai model dropped from almost 58,000 kW per year to almost 42,000 kW with a total energy savings of 18.6% (including all energy consumption parameters). On the other hand, London model results showed that the annual interior space heating dropped from almost 36,000 kW to almost 28,000 kW with a total energy savings of 16.4%.