Chi Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chi Zhang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Chenghao He
State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
1 shared publication - Hui Zhang
State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, China
1 shared publication - Xiaobo Rui
Tianjin University
1 shared publication - Yongshuai Ma
State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
1 shared publication - Zhuochen Wang
College of Mechanical and Electrical Engineering, Beijing University of Chemical Technology, Beijing, China
1 shared publication
Latest Publications
- Open Access
- 31 August 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (9) , 1008
Design and Fabrication of Air-Coupled CMUT for Non-Contact Temperature Measurement Applications
Compared with traditional piezoelectric transducers, Capacitive Micromachined Ultrasonic Transducers (CMUTs) have advantages such as better impedance matching with air, smaller size, lighter weight, higher sensitivity, and ease of array formation. Acoustic temperature measurement is a technology that utilizes the relationship between sound velocity and temperature to achieve non-contact temperature detection, with advantages such as fast response and non-invasiveness. CMUT-based acoustic temperature field measurement can achieve temperature detection in situations with narrow spaces, portability, and high measurement accuracy. This paper investigates an air-coupled CMUT device for acoustic temperature measurement, featuring a resonant frequency of 220 kHz, and composed of 16 × 8 cells. The design and fabrication of the CMUT array were completed, and the device characteristics were tested and characterized. A temperature field measurement method using mechanical scanning was proposed. A temperature measurement experimental system based on CMUT devices was constructed, achieving preliminary measurement of acoustic transmission time in both uniform and non-uniform temperature fields. Using a temperature field reconstruction algorithm, the measurement and imaging of the temperature field above an electric heating wire were accomplished and compared with the thermocouple-based temperature measurement experiment. The experimental results verified the feasibility of CMUT devices for non-contact temperature field measurement.
- 31 August 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (9) , 1008
Open AccessDesign and Fabrication of Air-Coupled CMUT for Non-Contact Temperature Measurement Applications
Compared with traditional piezoelectric transducers, Capacitive Micromachined Ultrasonic Transducers (CMUTs) have advantages such as better impedance matching with air, smaller size, lighter weight, higher sensitivity, and ease of array formation. Acoustic temperature measurement is a technology that utilizes the relationship between sound velocity and temperature to achieve non-contact temperature detection, with advantages such as fast response and non-invasiveness. CMUT-based acoustic temperature field measurement can achieve temperature detection in situations with narrow spaces, portability, and high measurement accuracy. This paper investigates an air-coupled CMUT device for acoustic temperature measurement, featuring a resonant frequency of 220 kHz, and composed of 16 × 8 cells. The design and fabrication of the CMUT array were completed, and the device characteristics were tested and characterized. A temperature field measurement method using mechanical scanning was proposed. A temperature measurement experimental system based on CMUT devices was constructed, achieving preliminary measurement of acoustic transmission time in both uniform and non-uniform temperature fields. Using a temperature field reconstruction algorithm, the measurement and imaging of the temperature field above an electric heating wire were accomplished and compared with the thermocouple-based temperature measurement experiment. The experimental results verified the feasibility of CMUT devices for non-contact temperature field measurement.