Fei Deng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fei Deng has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Xiaobin Zhang
Northwestern Polytechnical University
2 shared publications - Bocong Zhang
AVIC Tianjin Aviation Electro-Mechanical Co., Ltd., Tianjin 300308, China
1 shared publication - Shuhao Deng
School of Automation, Northwestern Polytechnical University, Xi’an 710060, China
1 shared publication - Tao Lei
Northwestern Polytechnical University
1 shared publication - Ting Wang
Department of Electrical Engineering, Northwestern Polytechnical University, Xi’an 710072, China
1 shared publication - Weilin Li
Northwestern Polytechnical University
1 shared publication
Latest Publications
- Open Access
Effect Analysis of Unbalanced Input Voltage on Diode Open-Circuit in 12-Pulse Transformer Rectifier Units
Unbalanced input voltage can significantly affect the electrical behavior of transformer rectifier units (TRUs), especially when a diode open-circuit (OC) fault breaks the original diode conduction symmetry. However, the effect of unbalanced input voltage on the diode OC fault has not been sufficiently clarified from the perspective of a conduction mechanism. This paper analyzes the effect of unbalanced input voltage on diode OC faults in TRUs by establishing a conduction-oriented mechanism. Unbalanced input voltage is divided into two forms, namely, unequal magnitude and phase-shift deviation. The effects on diode conduction boundaries, conduction angles, and conduction intervals are first derived theoretically. Then, using a 12-pulse TRU with and OC faults as representative cases, current and voltage responses are investigated in both time and frequency domains. The experimental results show that the two forms change diode conduction intervals in different ways. In particular, an unequal magnitude changes the relative driving voltage dominance near the conduction boundaries, resulting in the stretching or compression of diode conduction intervals; phase-shift deviation shifts the angular positions of the driving voltages and modifies the commutation timing. Two forms further aggravate waveform asymmetry and enhance low-order and non-characteristic harmonics under diode OC fault conditions. This effect analysis provides a more comprehensive basis for understanding diode OC fault responses in 12-pulse TRUs and supports the development of more robust diode OC fault diagnosis methods under non-ideal input voltage conditions.Open AccessEffect Analysis of Unbalanced Input Voltage on Diode Open-Circuit in 12-Pulse Transformer Rectifier Units
Unbalanced input voltage can significantly affect the electrical behavior of transformer rectifier units (TRUs), especially when a diode open-circuit (OC) fault breaks the original diode conduction symmetry. However, the effect of unbalanced input voltage on the diode OC fault has not been sufficiently clarified from the perspective of a conduction mechanism. This paper analyzes the effect of unbalanced input voltage on diode OC faults in TRUs by establishing a conduction-oriented mechanism. Unbalanced input voltage is divided into two forms, namely, unequal magnitude and phase-shift deviation. The effects on diode conduction boundaries, conduction angles, and conduction intervals are first derived theoretically. Then, using a 12-pulse TRU with and OC faults as representative cases, current and voltage responses are investigated in both time and frequency domains. The experimental results show that the two forms change diode conduction intervals in different ways. In particular, an unequal magnitude changes the relative driving voltage dominance near the conduction boundaries, resulting in the stretching or compression of diode conduction intervals; phase-shift deviation shifts the angular positions of the driving voltages and modifies the commutation timing. Two forms further aggravate waveform asymmetry and enhance low-order and non-characteristic harmonics under diode OC fault conditions. This effect analysis provides a more comprehensive basis for understanding diode OC fault responses in 12-pulse TRUs and supports the development of more robust diode OC fault diagnosis methods under non-ideal input voltage conditions. - Open Access
Optimization Strategy for Multi-Motor Cooperative Energy Recovery in Distributed Electric Propulsion Aircraft
Distributed Electric Propulsion aircraft have gained significant attention for advancing green aviation. However, their application is constrained by the limited energy density of batteries, resulting in weight compensation and flight range limitation. Current research on DEP energy management predominantly focuses on thrust allocation during the cruise phase while largely neglecting the energy regeneration potential during the descent phase. Conventional all-motors active energy recovery strategies force the multi-motor array to operate within a low-efficiency region, since the required drag torque is small under low aerodynamic drag conditions. To solve this issue, this paper proposes an energy recovery strategy that dynamically adjusts the number of activated motors during the descent phase of aircraft. The proposed N-Active strategy can adaptively regulate the number of operating motors, shifting motor operating points from the low-efficiency region to the high-efficiency region, which effectively decouples energy regulation within the longitudinal symmetry plane and maximizes energy recovery benefits. In this study, a high-fidelity simulation platform is established, including nonlinear aerodynamic characteristics and propeller windmilling motor efficiency models. Moreover, the optimal performance of the N-Active multi-motor cooperative energy recovery optimization strategy is verified based on the constructed platform. Simulation results demonstrate that compared with the traditional all motors active strategy, the proposed method improves battery state of charge by 11.96% and reduces virtual weight of battery. This method can effectively alleviate the weight compensation effect of distributed electric propulsion aircraft without additional physical weight increment, thereby enhancing the loading capacity of aircraft.
Open AccessOptimization Strategy for Multi-Motor Cooperative Energy Recovery in Distributed Electric Propulsion Aircraft
Distributed Electric Propulsion aircraft have gained significant attention for advancing green aviation. However, their application is constrained by the limited energy density of batteries, resulting in weight compensation and flight range limitation. Current research on DEP energy management predominantly focuses on thrust allocation during the cruise phase while largely neglecting the energy regeneration potential during the descent phase. Conventional all-motors active energy recovery strategies force the multi-motor array to operate within a low-efficiency region, since the required drag torque is small under low aerodynamic drag conditions. To solve this issue, this paper proposes an energy recovery strategy that dynamically adjusts the number of activated motors during the descent phase of aircraft. The proposed N-Active strategy can adaptively regulate the number of operating motors, shifting motor operating points from the low-efficiency region to the high-efficiency region, which effectively decouples energy regulation within the longitudinal symmetry plane and maximizes energy recovery benefits. In this study, a high-fidelity simulation platform is established, including nonlinear aerodynamic characteristics and propeller windmilling motor efficiency models. Moreover, the optimal performance of the N-Active multi-motor cooperative energy recovery optimization strategy is verified based on the constructed platform. Simulation results demonstrate that compared with the traditional all motors active strategy, the proposed method improves battery state of charge by 11.96% and reduces virtual weight of battery. This method can effectively alleviate the weight compensation effect of distributed electric propulsion aircraft without additional physical weight increment, thereby enhancing the loading capacity of aircraft.
- Open Access
- 27 August 2025
- Published by IntechOpen
Advanced Power Management in Renewable Energy Microgrids
This chapter illustrates the power management issues in renewable energy microgrids. Firstly, the system structure and operation modes of renewable energy microgrids are presented. On this basis, the power management issues in both grid-connected and islanded microgrids are discussed. In grid-connected microgrids, the key point is suppressing the negative effect from the load side. In steady states, when unbalanced and nonlinear loads are supplied, the unbalanced and harmonic components in grid current are eliminated to improve grid power quality. On the other hand, inertia emulation is implemented in the controller of power converters in microgrids to ease the impact of load disturbance on grid frequency, and it can be realized via capacitors at the DC side of grid-tied inverters, DC-side distributed generation units, and other methods (e.g., smart loads). As for the power management in islanded microgrids, the essential target is eliminating the impact of mismatched feeder impedances and then achieving equal/proportional power sharing between parallel distributed generation units. Generally, power droop control can be designed based on feeder impedance characteristics, and the adaptive virtual impedance regulation is also effective in realizing accurate power sharing. After that, the future trends in this field are predicted, and the power management in renewable energy microgrids faces the challenge of new power converter functions and coordination with multiple control targets. Meanwhile, emerging techniques, for example, digital twins, virtual power plants, and artificial intelligence, are effective in improving the power management performance in microgrids.
- 27 August 2025
- Published by IntechOpen
Open AccessAdvanced Power Management in Renewable Energy Microgrids
This chapter illustrates the power management issues in renewable energy microgrids. Firstly, the system structure and operation modes of renewable energy microgrids are presented. On this basis, the power management issues in both grid-connected and islanded microgrids are discussed. In grid-connected microgrids, the key point is suppressing the negative effect from the load side. In steady states, when unbalanced and nonlinear loads are supplied, the unbalanced and harmonic components in grid current are eliminated to improve grid power quality. On the other hand, inertia emulation is implemented in the controller of power converters in microgrids to ease the impact of load disturbance on grid frequency, and it can be realized via capacitors at the DC side of grid-tied inverters, DC-side distributed generation units, and other methods (e.g., smart loads). As for the power management in islanded microgrids, the essential target is eliminating the impact of mismatched feeder impedances and then achieving equal/proportional power sharing between parallel distributed generation units. Generally, power droop control can be designed based on feeder impedance characteristics, and the adaptive virtual impedance regulation is also effective in realizing accurate power sharing. After that, the future trends in this field are predicted, and the power management in renewable energy microgrids faces the challenge of new power converter functions and coordination with multiple control targets. Meanwhile, emerging techniques, for example, digital twins, virtual power plants, and artificial intelligence, are effective in improving the power management performance in microgrids.