Yingwei Qin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yingwei Qin has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Ping Chen
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, China
2 shared publications Sukai Wang
North University of China
2 shared publicationsXueqin Sun
2 shared publicationsYihong Li
North University of China
2 shared publicationsYu Li
2 shared publications- Xiaojie Zhao
North University of China
1 shared publication
Latest Publications
- 22 October 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (22) , 46199-46212
Global physics-guided grayscale correction in multi-view detectors
Multi-view X-ray imaging systems extend the imaging field of view by integrating multiple imaging modules. Nevertheless, inter-module performance variations in detector arrays, gain drift, and angle-dependent effects cause cross-view grayscale inconsistencies, which degrade overall imaging quality. While existing X-ray imaging approaches primarily rely on single-view flat-field correction or per-projection normalization, these strategies remain inadequate for achieving global consistency across views. To overcome this limitation, this study proposes a physics-constrained multi-view image correction (PCMIC) method. By constructing a globally shared attenuation field to model view-specific nonlinear responses and incorporating boundary anchoring together with monotonicity constraints, the method ensures strong physical fidelity. Experiments conducted on a self-developed large-field, high-resolution micro-CT system demonstrate that PCMIC effectively suppresses stitching artifacts and improves grayscale consistency, structural fidelity, and quantitative stability.
- 22 October 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (22) , 46199-46212
Global physics-guided grayscale correction in multi-view detectors
Multi-view X-ray imaging systems extend the imaging field of view by integrating multiple imaging modules. Nevertheless, inter-module performance variations in detector arrays, gain drift, and angle-dependent effects cause cross-view grayscale inconsistencies, which degrade overall imaging quality. While existing X-ray imaging approaches primarily rely on single-view flat-field correction or per-projection normalization, these strategies remain inadequate for achieving global consistency across views. To overcome this limitation, this study proposes a physics-constrained multi-view image correction (PCMIC) method. By constructing a globally shared attenuation field to model view-specific nonlinear responses and incorporating boundary anchoring together with monotonicity constraints, the method ensures strong physical fidelity. Experiments conducted on a self-developed large-field, high-resolution micro-CT system demonstrate that PCMIC effectively suppresses stitching artifacts and improves grayscale consistency, structural fidelity, and quantitative stability.
- 28 August 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (18) , 38113-38126
Large-FOV high-resolution micro-CT via cascaded fiber tapers
Micro-CT imaging is widely used in materials science, biomedical research, geological exploration, and industrial inspection due to its non-destructive capabilities. However, traditional systems face challenges due to limitations in spatial bandwidth product (SBP), making it difficult to achieve both a large field-of-view (FOV) and high-resolution imaging simultaneously. This paper presents a segmented light deflection method using cascaded optical fiber tapers integrated within a “fiber taper–image intensifier-camera” coupling architecture. This design reduces distortion caused by large taper ratios in single-stage systems. Additionally, a multi-view geometric registration calibration approach is developed based on CT projection geometric constraints to address mismatches between traditional 2D planar distortion correction methods and CT projection geometry. A cascaded fiber taper array (53 mm input - 34 mm intermediate - 16 mm output) was implemented in a 2 × 2 tiling configuration. The system achieves wide-FOV micro-CT imaging with a maximum imaging area of 106.4 × 106.4 mm2. Resolution testing confirmed a 3 μm resolution within a 4.1 × 4.1 mm2 FOV. System reconstruction efficacy was validated through rock core and printed circuit board (PCB) samples.
- 28 August 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (18) , 38113-38126
Large-FOV high-resolution micro-CT via cascaded fiber tapers
Micro-CT imaging is widely used in materials science, biomedical research, geological exploration, and industrial inspection due to its non-destructive capabilities. However, traditional systems face challenges due to limitations in spatial bandwidth product (SBP), making it difficult to achieve both a large field-of-view (FOV) and high-resolution imaging simultaneously. This paper presents a segmented light deflection method using cascaded optical fiber tapers integrated within a “fiber taper–image intensifier-camera” coupling architecture. This design reduces distortion caused by large taper ratios in single-stage systems. Additionally, a multi-view geometric registration calibration approach is developed based on CT projection geometric constraints to address mismatches between traditional 2D planar distortion correction methods and CT projection geometry. A cascaded fiber taper array (53 mm input - 34 mm intermediate - 16 mm output) was implemented in a 2 × 2 tiling configuration. The system achieves wide-FOV micro-CT imaging with a maximum imaging area of 106.4 × 106.4 mm2. Resolution testing confirmed a 3 μm resolution within a 4.1 × 4.1 mm2 FOV. System reconstruction efficacy was validated through rock core and printed circuit board (PCB) samples.