Gianfrancesco Gallina
Research Subjects
Gianfrancesco Gallina has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Marco Givonetti
Masera Engineering Group S.r.l.
3 shared publications - Mattia Mairone
Politecnico di Torino
3 shared publications - Mauro Corrado
Politecnico di Torino
3 shared publications D. Masera
2 shared publications- Giuseppe Andrea Ferro
Department of Structural, Geotechnical and Building Engineering, DISEG, Politecnico di Torino, 10129 Torino, Italy
2 shared publications - Raffaele Tarantini
Politecnico di Torino
2 shared publications
Latest Publications
- 30 October 2025
- Published by Springer Nature
- p. 313-329
Ultimate Limit State Behavior of RC Members in Bending Strengthened with GFRP Rebars
- 30 October 2025
- Published by Springer Nature
- p. 313-329
Ultimate Limit State Behavior of RC Members in Bending Strengthened with GFRP Rebars
- 20 August 2025
- Published by Taylor & Francis
- p. 527-528
Seismic vulnerability assessment of RC bridge piers strengthened with GFRP rebars: A case study
This study evaluates the seismic vulnerability of Reinforced Concrete (RC) bridge piers retrofitted with Glass Fiber Reinforced Polymer (GFRP) rebars. GFRP offers corrosion resistance and high strength-to-weight ratio but has limited ductility. A hybrid jacketing technique combining steel and GFRP rebars is applied. The study employs Pushover Analysis (POA) using a fiber-based approach to compare the seismic performance of the as-built and retrofitted structures. Results indicate enhanced strength and durability with hybrid jacketing, while the Seismic Vulnerability Index (SVI) confirms improved seismic resilience.
- 20 August 2025
- Published by Taylor & Francis
- p. 527-528
Seismic vulnerability assessment of RC bridge piers strengthened with GFRP rebars: A case study
This study evaluates the seismic vulnerability of Reinforced Concrete (RC) bridge piers retrofitted with Glass Fiber Reinforced Polymer (GFRP) rebars. GFRP offers corrosion resistance and high strength-to-weight ratio but has limited ductility. A hybrid jacketing technique combining steel and GFRP rebars is applied. The study employs Pushover Analysis (POA) using a fiber-based approach to compare the seismic performance of the as-built and retrofitted structures. Results indicate enhanced strength and durability with hybrid jacketing, while the Seismic Vulnerability Index (SVI) confirms improved seismic resilience.
- 7 August 2025
- Published by Taylor & Francis
- p. 1487-1492
Seismic vulnerability assessment of RC bridge piers strengthened with GFRP rebars: A case study
The use of Glass Fiber Reinforced Polymer (GFRP) bars for retrofitting bridges piers under seismic excitation is an advanced technique that offers several benefits due to the material's unique properties, in terms of high strength-to-weight ratio, insensitivity to corrosion, and high durability. Throughout the world, a large number of outdated structures, particularly those made of reinforced concrete, require urgent repairing interventions due to a variety of factors, including environmental effects, inadequate construction details, and neglected maintenance. Engineers who want to increase the longevity and safety of bridge structures in seismic regions can find great benefits in the application of GFRP. An existing bridge is considered as case study. The strengthening design strategy aims to increase the lateral resistance by slightly altering the lateral displacement ductility. To this aim, a hybrid retrofitting with steel and GFRP rebars is designed to be applied through the jacketing technique. The force-deformation curves of the nonlinear plastic hinges are determined using a fiber approach, after validation of the constitutive models. A Pushover Analysis (POA) with lumped plasticity is implemented in order to compare the seismic response of the original structure with the retrofitted one. The capacity of the structure and thus its Seismic Vulnerability Index (SVI) and differences in overall structural response are evaluated.
- 7 August 2025
- Published by Taylor & Francis
- p. 1487-1492
Seismic vulnerability assessment of RC bridge piers strengthened with GFRP rebars: A case study
The use of Glass Fiber Reinforced Polymer (GFRP) bars for retrofitting bridges piers under seismic excitation is an advanced technique that offers several benefits due to the material's unique properties, in terms of high strength-to-weight ratio, insensitivity to corrosion, and high durability. Throughout the world, a large number of outdated structures, particularly those made of reinforced concrete, require urgent repairing interventions due to a variety of factors, including environmental effects, inadequate construction details, and neglected maintenance. Engineers who want to increase the longevity and safety of bridge structures in seismic regions can find great benefits in the application of GFRP. An existing bridge is considered as case study. The strengthening design strategy aims to increase the lateral resistance by slightly altering the lateral displacement ductility. To this aim, a hybrid retrofitting with steel and GFRP rebars is designed to be applied through the jacketing technique. The force-deformation curves of the nonlinear plastic hinges are determined using a fiber approach, after validation of the constitutive models. A Pushover Analysis (POA) with lumped plasticity is implemented in order to compare the seismic response of the original structure with the retrofitted one. The capacity of the structure and thus its Seismic Vulnerability Index (SVI) and differences in overall structural response are evaluated.