RPRui Prado
Rui Prado
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rui Prado has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Diogo Sousa
INEGI—Institute of Science and Innovation in Mechanical and Industrial Engineering, 4200-465 Porto, Portugal
1 shared publication - Dulce A. Oliveira
INEGI—Institute of Science and Innovation in Mechanical and Industrial Engineering, 4200-465 Porto, Portugal
1 shared publication - Filipa Santos
INEGI—Institute of Science and Innovation in Mechanical and Industrial Engineering, 4200-465 Porto, Portugal
1 shared publication - Luana Rodrigues
INEGI—Institute of Science and Innovation in Mechanical and Industrial Engineering, 4200-465 Porto, Portugal
1 shared publication - Susana Moreira
ULS São João—Hospital São João, 4200-319 Porto, Portugal
1 shared publication
Latest Publications
- Open Access
- 3 September 2025
- Published by MDPI AG in Electronics
- Vol. 14 (17) , 3525
SafeBladder: Development and Validation of a Non-Invasive Wearable Device for Neurogenic Bladder Volume Monitoring
Neurogenic bladder is a debilitating condition caused by neurological dysfunction that impairs urinary control, often requiring timed intermittent catheterisation. Although effective, intermittent catheterisation is invasive, uncomfortable, and associated with infection risks, reducing patients’ quality of life. SafeBladder is a low-cost wearable device developed to enable real-time, non-invasive bladder volume monitoring using near-infrared spectroscopy (NIRS) and machine learning algorithms. The prototype employs LEDs and photodetectors to measure light attenuation through abdominal tissues. Bladder filling was simulated through experimental tests using stepwise water additions to containers and tissue-mimicking phantoms, including silicone and porcine tissue. Machine learning models, including Linear Regression, Support Vector Regression, and Random Forest, were trained to predict volume from sensor data. The results showed the device is sensitive to volume changes, though ambient light interference affected accuracy, suggesting optimal use under clothing or in low-light conditions. The Random Forest model outperformed others, with a Mean Absolute Error (MAE) of 25 ± 4 mL and of 0.90 in phantom tests. These findings support SafeBladder as a promising, non-invasive solution for bladder monitoring, with clinical potential pending further calibration and validation in real-world settings.- 3 September 2025
- Published by MDPI AG in Electronics
- Vol. 14 (17) , 3525
Open AccessSafeBladder: Development and Validation of a Non-Invasive Wearable Device for Neurogenic Bladder Volume Monitoring
Neurogenic bladder is a debilitating condition caused by neurological dysfunction that impairs urinary control, often requiring timed intermittent catheterisation. Although effective, intermittent catheterisation is invasive, uncomfortable, and associated with infection risks, reducing patients’ quality of life. SafeBladder is a low-cost wearable device developed to enable real-time, non-invasive bladder volume monitoring using near-infrared spectroscopy (NIRS) and machine learning algorithms. The prototype employs LEDs and photodetectors to measure light attenuation through abdominal tissues. Bladder filling was simulated through experimental tests using stepwise water additions to containers and tissue-mimicking phantoms, including silicone and porcine tissue. Machine learning models, including Linear Regression, Support Vector Regression, and Random Forest, were trained to predict volume from sensor data. The results showed the device is sensitive to volume changes, though ambient light interference affected accuracy, suggesting optimal use under clothing or in low-light conditions. The Random Forest model outperformed others, with a Mean Absolute Error (MAE) of 25 ± 4 mL and of 0.90 in phantom tests. These findings support SafeBladder as a promising, non-invasive solution for bladder monitoring, with clinical potential pending further calibration and validation in real-world settings.