YYYujie Yang

Yujie Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yujie Yang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Bad Data Identification Method Based on Optimal Weight-Tuning for Power System State Estimation

    by Bowen Hu, Yadong Zhou, Sizhe He, Yujie Yang, Yang Liu, Ting Liu, Xiaohong Guan

    The weighted least squares (WLS) method has been widely used in power systems for state estimation (SE), but in the presence of gross errors, the results of WLS SE can be significantly biased. While various bad data identification (BDI) methods exist, identifying multiple bad data for SE is still challenging, especially when bad data located at leverage points can disproportionately corrupt SE accuracy. This paper proposes an Optimal-Weighted Least Squares State Estimation (OWLS-SE) method with an optimal weight-tuning strategy to address these challenges. The impact of bad data at leverage points on estimation errors is first mathematically demonstrated through a theoretical upper bound of the SE relative error. Then, the optimal dynamic weights are developed to minimize this error bound by quantifying leverage point impacts and integrating them into a multi-objective optimization framework. The proposed OWLS-SE achieves simultaneous SE and BDI within a single optimization model, eliminating conventional two-stage processing. Numerical experiments on the 6- bus system, IEEE 30-, 118- bus systems, and the 2869- bus PEGASE system demonstrate that OWLS-SE achieves superior BDI and SE accuracy with robust performance even when multiple gross errors occur at leverage points, while maintaining computational efficiency comparable to the simplest WLS method.

  • IGNN: An Inference Graph Neural Network for Data Sensitivity Assessment Considering Data Inference Leakage in Cyber-Physical Power Grid

    by Bowen Hu, Rongtao Nie, Yadong Zhou, Sizhe He, Yujie Yang, Yang Liu, Ting Liu, Xiaohong Guan

    Modern Cyber-Physical Power Grids (CPPG) rely heavily on fine-grained data exchange, yet they face the concealed threat of Data Inference Leakage (DIL), where attackers infer sensitive parameters from seemingly non-sensitive data. Existing risk assessment methods typically focus on direct cyber-attacks or employ static binary classifications, failing to capture the dynamic risk propagation caused by complex physical and statistical data couplings. To address this, this paper proposes a unified data sensitivity assessment framework based on a novel Inference Graph Neural Network (IGNN). We first construct an inference relation graph that integrates both model-driven and data-driven correlations. An analytic hierarchy process (AHP) model is constructed to calibrate the intrinsic sensitivity baseline. Subsequently, a novel inference-weighted Graph Attention Network (GAT) is developed to quantify the final sensitivity by aggregating the risk propagating through the inference pathways. Experiments on IEEE 30-, 57-bus, ACTIV 200-bus, and case 1354-pegase systems demonstrate that the proposed method effectively quantifies data sensitivity and identifies high-risk data susceptible to DIL, exhibiting strong robustness across different system scales. Quantitative results indicate that the high-sensitivity data identified by our method yield a highly threatening inference accuracy of up to 0.9145, significantly outperforming GCN-based and rule-based benchmarks.

  • A Cyber–Physical Security Assessment Model for Distribution Grid With High Penetration of Electric Vehicle Charging Infrastructure

    by Yujie Yang, Yadong Zhou, Yang Liu, Sizhe He, Nanpeng Yu, Jiaxuan Fei, Ting Liu, Xiaohong Guan

    A distribution grid with electric vehicle (EV) charging infrastructure can be modeled as a coupled network consisting of a cyber network, a distribution grid, and a traffic network. The interconnection of the coupled network allows attackers to launch cyberattacks and control numerous EVs to cause severe load fluctuations, thereby affecting the normal operation of the distribution grid and the traffic flow. To evaluate the cyber–physical security of the coupled network, we present a security assessment model formulated as a coupled discrete event system specification (DEVS). In this model, the evolution of the coupled network is represented as state transitions triggered by events in a discrete-time process, while the interaction is achieved through event transmission, reception, and processing. To determine the redistribution of states influenced by the selection of EV charging stations and moving paths, we propose a spatial–temporal evolution mechanism. Based on the assessment model, we propose an event-triggered simulation method. The efficiency of the proposed simulation method is evaluated by comparing it with the multilayer synchronous simulation method. Compared with the existing security assessment models, the simulation results of our model are more accurate.


  • A Markov Tree Model for Cascading Failure Risk Assessment in Power Grid With Uncertain Renewable Energy Generation

    by Yujie Yang, Yadong Zhou, Sizhe He, Bowen Hu, Yu Qu, Ting Liu, Xiaohong Guan

    The increasing penetration of renewable energy generation (REG) introduces significant uncertainty into power grids, posing heightened risks for cascading failures. In this paper, a Markov tree model is proposed to assess the risk of cascading failure in power grid with uncertain REG. The model captures the diverse failure paths caused by REG uncertainty, representing the cascading failure process as a sequence of state transitions with probabilities reflecting the likelihood of state transitions. To identify critical tripping branches during cascading failure propagation, a hybrid probability-interval method is introduced. Probabilistic power flow analysis identifies branches with overload risk, while interval positional relationships rank their severity. To improve the efficiency of risk assessment, a risk-based depth-first search (R-DFS) method is proposed. This method uses estimated risk indices to prioritize high-risk failure paths while pruning low-risk paths, significantly reducing simulation time while maintaining assessment accuracy. Compared with existing models, the proposed model balances simulation efficiency and accuracy, effectively identifying high-risk failure paths under REG uncertainty. Simulation results demonstrate the impact of threshold selection on the retention of high-risk paths and simulation performance, providing insights into managing cascading failure risks in power grid with high REG penetration.