Umberto Mosca
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Umberto Mosca has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Gabriella Olmo
Department of Control and Computer Engineering, Politecnico di Torino, 10129 Turin, Italy
4 shared publications - Alessandro Cicolin
University of Turin
3 shared publications - Irene Rechichi
Politecnico di Torino
3 shared publications Alessandro Cicolin
1 shared publication- Alessandro Zampogna
Department of Human Neurosciences, Sapienza University of Rome, 00185 Rome, Italy
1 shared publication - Antonio Suppa
Department of Human Neurosciences Sapienza University of Rome Rome Italy
1 shared publication
Latest Publications
- Open Access
- 1 July 2026
- Published by MDPI AG in Algorithms
- Vol. 19 (7) , 531
Full-Night Comparison of ECG- and PPG-Derived Measures of Cardiac Variability for Sleep Disorder Screening
Polysomnography (PSG) is the gold standard for diagnosing sleep disorders, but its complexity and cost limit widespread use. Heart rate variability (HRV) is traditionally assessed from electrocardiography (ECG), while photoplethysmography (PPG), widely available in wearable devices, offers a more accessible alternative. However, its reliability over full-night recordings remains underexplored. This study analyzes data from 50 subjects across five groups (healthy controls, rapid eye movement sleep behavior disorder, obstructive sleep apnea, periodic limb movements, and mixed comorbidities) to assess agreement between ECG-derived HRV and PPG-derived pulse rate variability (PRV), considering time-, frequency-, and nonlinear-domain features. Correlation and equivalence analyses were performed, with and without removal of artifactual segments. Correlation coefficients exceeded 0.6 for most features and improved to above 0.7 after artifact removal. Consistent improvements were observed across all subject groups. Equivalence testing further identified a subset of features showing high agreement and low bias. The results indicate that, with appropriate pre-processing, PPG can approximate ECG-derived variability in full-night sleep recordings. The identification of robust features for screening purposes supports the use of PRV for wearable-based screening and monitoring in heterogeneous sleep disorder populations.
- 1 July 2026
- Published by MDPI AG in Algorithms
- Vol. 19 (7) , 531
Open AccessFull-Night Comparison of ECG- and PPG-Derived Measures of Cardiac Variability for Sleep Disorder Screening
Polysomnography (PSG) is the gold standard for diagnosing sleep disorders, but its complexity and cost limit widespread use. Heart rate variability (HRV) is traditionally assessed from electrocardiography (ECG), while photoplethysmography (PPG), widely available in wearable devices, offers a more accessible alternative. However, its reliability over full-night recordings remains underexplored. This study analyzes data from 50 subjects across five groups (healthy controls, rapid eye movement sleep behavior disorder, obstructive sleep apnea, periodic limb movements, and mixed comorbidities) to assess agreement between ECG-derived HRV and PPG-derived pulse rate variability (PRV), considering time-, frequency-, and nonlinear-domain features. Correlation and equivalence analyses were performed, with and without removal of artifactual segments. Correlation coefficients exceeded 0.6 for most features and improved to above 0.7 after artifact removal. Consistent improvements were observed across all subject groups. Equivalence testing further identified a subset of features showing high agreement and low bias. The results indicate that, with appropriate pre-processing, PPG can approximate ECG-derived variability in full-night sleep recordings. The identification of robust features for screening purposes supports the use of PRV for wearable-based screening and monitoring in heterogeneous sleep disorder populations.
- Open Access
- 11 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Wearable-Enabled Screening of REM Sleep Behavior Disorder: Cross-Dataset Validation of a Heart Rate Variability-Based Machine Learning Approach
REM Sleep Behavior Disorder (RBD) is a reliable prodromal marker of synucleinopathies, including Parkinson's Disease, yet it often remains underdiagnosed due to the need for specialized and intrusive assessments. Heart Rate Variability (HRV), reflecting autonomic dysfunction, often associated with RBD, offers a non-intrusive alternative that can be collected via wearable devices, thus enabling scalable early screening. This study investigates the feasibility of automatically detecting RBD with Machine Learning (ML), using HRV features, including linear and nonlinear metrics. Electrocardiographic (ECG)recordings from four datasets (three public, one private) were employed, comprising healthy controls, RBD subjects, and subjects with Obstructive Sleep Apnea (OSAS). OSAS cases were deliberately included to evaluate model robustness under realistic, real-world screening scenarios with confounding sleep disturbances. Among tested feature selection and classifier combinations, the best models achieved an average Accuracy of 88.0 ± 3.5% and an F1-score of 89.3 ± 2.6% for the Healthy versus RBD classification. Including OSAS subjects (identified as non-RBD) slightly reduced performance (Accuracy: 85.9 ± 4.7%, F1score: 79.4 ± 8.7%), but maintained promising results. These findings demonstrate the potential of HRVbased ML models to support early RBD detection, facilitating timely intervention and monitoring in highrisk populations, through non-intrusive, scalable, and wearable-compatible data collection.
- 11 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessWearable-Enabled Screening of REM Sleep Behavior Disorder: Cross-Dataset Validation of a Heart Rate Variability-Based Machine Learning Approach
REM Sleep Behavior Disorder (RBD) is a reliable prodromal marker of synucleinopathies, including Parkinson's Disease, yet it often remains underdiagnosed due to the need for specialized and intrusive assessments. Heart Rate Variability (HRV), reflecting autonomic dysfunction, often associated with RBD, offers a non-intrusive alternative that can be collected via wearable devices, thus enabling scalable early screening. This study investigates the feasibility of automatically detecting RBD with Machine Learning (ML), using HRV features, including linear and nonlinear metrics. Electrocardiographic (ECG)recordings from four datasets (three public, one private) were employed, comprising healthy controls, RBD subjects, and subjects with Obstructive Sleep Apnea (OSAS). OSAS cases were deliberately included to evaluate model robustness under realistic, real-world screening scenarios with confounding sleep disturbances. Among tested feature selection and classifier combinations, the best models achieved an average Accuracy of 88.0 ± 3.5% and an F1-score of 89.3 ± 2.6% for the Healthy versus RBD classification. Including OSAS subjects (identified as non-RBD) slightly reduced performance (Accuracy: 85.9 ± 4.7%, F1score: 79.4 ± 8.7%), but maintained promising results. These findings demonstrate the potential of HRVbased ML models to support early RBD detection, facilitating timely intervention and monitoring in highrisk populations, through non-intrusive, scalable, and wearable-compatible data collection.
- Open Access
Early Detection of Dysphagia Signs in Parkinson’s Disease: An Artificial Intelligence-Based Approach Using Non-Invasive Sensors
The present study evaluates the effectiveness of a non-invasive wearable sensor system, combining accelerometers, surface electromyography, and artificial intelligence, to objectively characterize swallowing in elderly individuals affected by Parkinson’s Disease, without clinically manifested dysphagia. A cohort of patients and healthy control subjects performed the same swallowing test protocol, including tasks with different viscosity boluses, positioning a commercial adhesive grid of High-Density surface Electromyography (HD-sEMG) electrodes on the submental muscle and a triaxial accelerometer over the thyroid cartilage. Relevant temporal and spectral features were extracted from electromyography data. Proper filtering and processing by machine learning and Principal Component Analysis allowed identification of two distinct clusters of subjects, one predominantly composed of controls with just a few patients, the other mostly crowded by patients. Excellent classification performances were achieved (accuracy = 83.3%, precision = 79.0%, recall = 90.7%, F1-score = 84.5%, Cohen’s kappa = 0.67), revealing consistent differences in muscle activation patterns among subjects, even in the absence of clinically diagnosed dysphagia. These results support the feasibility of wearable sensor-based assessment as a reliable and non-invasive tool for the early detection of subclinical swallowing dysfunction in Parkinson’s Disease.
Open AccessEarly Detection of Dysphagia Signs in Parkinson’s Disease: An Artificial Intelligence-Based Approach Using Non-Invasive Sensors
The present study evaluates the effectiveness of a non-invasive wearable sensor system, combining accelerometers, surface electromyography, and artificial intelligence, to objectively characterize swallowing in elderly individuals affected by Parkinson’s Disease, without clinically manifested dysphagia. A cohort of patients and healthy control subjects performed the same swallowing test protocol, including tasks with different viscosity boluses, positioning a commercial adhesive grid of High-Density surface Electromyography (HD-sEMG) electrodes on the submental muscle and a triaxial accelerometer over the thyroid cartilage. Relevant temporal and spectral features were extracted from electromyography data. Proper filtering and processing by machine learning and Principal Component Analysis allowed identification of two distinct clusters of subjects, one predominantly composed of controls with just a few patients, the other mostly crowded by patients. Excellent classification performances were achieved (accuracy = 83.3%, precision = 79.0%, recall = 90.7%, F1-score = 84.5%, Cohen’s kappa = 0.67), revealing consistent differences in muscle activation patterns among subjects, even in the absence of clinically diagnosed dysphagia. These results support the feasibility of wearable sensor-based assessment as a reliable and non-invasive tool for the early detection of subclinical swallowing dysfunction in Parkinson’s Disease.
- Open Access
- 3 September 2025
- Published by Springer Nature in Research Square
Exploring Heart Rate Variability Feature Importance for REM Sleep Behavior Disorder Classification: A Comprehensive Multi Dataset Study
Heart rate variability (HRV) is a promising biomarker for detecting subtle autonomic alterations in sleep disorders such as REM Sleep Behavior Disorder (RBD). However, the relevance of HRV-derived features depends heavily on methodological choices, including data segmentation, preprocessing, and dataset composition. This study systematically investigates how four key factors (epoch duration, inclusion of wake segments, dataset heterogeneity, and the presence of comorbidities such as Obstructive Sleep Apnea Syndrome (OSAS)), affect HRV feature discriminative power. Using multiple polysomnography datasets, we extract a comprehensive suite of 528 features per subject and evaluate their importance using a combination of statistical and machine learningbased techniques. Results show that longer epochs typically yield more robust features, though shorter windows enhance the prominence of nonlinear metrics. Including wake segments improves feature relevance in heterogeneous datasets, supporting their use in real-world conditions. Furthermore, dataset aggregation enhances generalizability for full-night recordings, but may reduce performance when analyzing sleep-only data. Finally, including OSAS subjects had minimal effect on top-ranked features, indicating the robustness of HRV-based RBD markers across varying clinical contexts. These findings highlight the importance of thoughtful experimental design in HRV-based classification models in sleep research.
- 3 September 2025
- Published by Springer Nature in Research Square
Open AccessExploring Heart Rate Variability Feature Importance for REM Sleep Behavior Disorder Classification: A Comprehensive Multi Dataset Study
Heart rate variability (HRV) is a promising biomarker for detecting subtle autonomic alterations in sleep disorders such as REM Sleep Behavior Disorder (RBD). However, the relevance of HRV-derived features depends heavily on methodological choices, including data segmentation, preprocessing, and dataset composition. This study systematically investigates how four key factors (epoch duration, inclusion of wake segments, dataset heterogeneity, and the presence of comorbidities such as Obstructive Sleep Apnea Syndrome (OSAS)), affect HRV feature discriminative power. Using multiple polysomnography datasets, we extract a comprehensive suite of 528 features per subject and evaluate their importance using a combination of statistical and machine learningbased techniques. Results show that longer epochs typically yield more robust features, though shorter windows enhance the prominence of nonlinear metrics. Including wake segments improves feature relevance in heterogeneous datasets, supporting their use in real-world conditions. Furthermore, dataset aggregation enhances generalizability for full-night recordings, but may reduce performance when analyzing sleep-only data. Finally, including OSAS subjects had minimal effect on top-ranked features, indicating the robustness of HRV-based RBD markers across varying clinical contexts. These findings highlight the importance of thoughtful experimental design in HRV-based classification models in sleep research.