Marjan Nassajpour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marjan Nassajpour has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Amie Rosenfeld
Department of Neurology, Comprehensive Center for Brain Health, University of Miami, Boca Raton, FL, United States
1 shared publication- Amie Rosenfeld
Comprehensive Center for Brain Health, Department of Neurology, University of Miami, Boca Raton, FL 33433, USA
1 shared publication - Behnaz Ghoraani
Department of Computer and Electrical Engineering and Computer Science, Florida Atlantic University
1 shared publication - Behnaz Ghoraani
Department of Computer and Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL, United States
1 shared publication James E. Galvin
Department of Neurology, Comprehensive Center for Brain Health, University of Miami, Boca Raton, FL, United States
1 shared publication- James E. Galvin
University of Miami Miller School of Medicine
1 shared publication
Latest Publications
- Open Access
Comparison of Wearable and Depth-Sensing Technologies with Electronic Walkway for Comprehensive Gait Analysis
Accurate and scalable gait assessment is essential for clinical and research applications, including fall risk evaluation, rehabilitation monitoring, and early detection of neurodegenerative diseases. While electronic walkways remain the clinical gold standard, their high cost and limited portability restrict widespread use. Wearable inertial measurement units (IMUs) and markerless depth cameras have emerged as promising alternatives; however, prior studies have typically assessed these systems under tightly controlled conditions, with single participants in view, limited marker sets, and without direct cross-technology comparisons. This study addresses these gaps by simultaneously evaluating three sensing technologies—APDM wearable IMUs (tested in two separate configurations: foot-mounted and lumbar-mounted) and the Azure Kinect depth camera—against ProtoKinetics Zeno™ Walkway Gait Analysis System in a realistic clinical environment where multiple individuals were present in the camera’s field of view. Gait data from 20 older adults (mean age years) performing Single-Task and Dual-Task walking trials were synchronously captured using custom hardware for precise temporal alignment. Eleven gait markers spanning macro, micro-temporal, micro-spatial, and spatiotemporal domains were compared using mean absolute error (MAE), Pearson correlation (r), and Bland–Altman analysis. Foot-mounted IMUs demonstrated the highest accuracy (MAE –, –), followed closely by the Azure Kinect (MAE –, –0.98). Lumbar-mounted IMUs showed consistently lower agreement with the reference system. These findings provide the first comprehensive comparison of wearable and depth-sensing technologies with a clinical gold standard under real-world conditions and across an extensive set of gait markers. The results establish a foundation for deploying scalable, low-cost gait assessment systems in diverse healthcare contexts, supporting early detection, mobility monitoring, and rehabilitation outcomes across multiple patient populations.Open AccessComparison of Wearable and Depth-Sensing Technologies with Electronic Walkway for Comprehensive Gait Analysis
Accurate and scalable gait assessment is essential for clinical and research applications, including fall risk evaluation, rehabilitation monitoring, and early detection of neurodegenerative diseases. While electronic walkways remain the clinical gold standard, their high cost and limited portability restrict widespread use. Wearable inertial measurement units (IMUs) and markerless depth cameras have emerged as promising alternatives; however, prior studies have typically assessed these systems under tightly controlled conditions, with single participants in view, limited marker sets, and without direct cross-technology comparisons. This study addresses these gaps by simultaneously evaluating three sensing technologies—APDM wearable IMUs (tested in two separate configurations: foot-mounted and lumbar-mounted) and the Azure Kinect depth camera—against ProtoKinetics Zeno™ Walkway Gait Analysis System in a realistic clinical environment where multiple individuals were present in the camera’s field of view. Gait data from 20 older adults (mean age years) performing Single-Task and Dual-Task walking trials were synchronously captured using custom hardware for precise temporal alignment. Eleven gait markers spanning macro, micro-temporal, micro-spatial, and spatiotemporal domains were compared using mean absolute error (MAE), Pearson correlation (r), and Bland–Altman analysis. Foot-mounted IMUs demonstrated the highest accuracy (MAE –, –), followed closely by the Azure Kinect (MAE –, –0.98). Lumbar-mounted IMUs showed consistently lower agreement with the reference system. These findings provide the first comprehensive comparison of wearable and depth-sensing technologies with a clinical gold standard under real-world conditions and across an extensive set of gait markers. The results establish a foundation for deploying scalable, low-cost gait assessment systems in diverse healthcare contexts, supporting early detection, mobility monitoring, and rehabilitation outcomes across multiple patient populations. - Open Access
- 19 April 2024
- Published by Frontiers Media SA in Frontiers in Digital Health
- Vol. 6, 1366176
Objective estimation of m-CTSIB balance test scores using wearable sensors and machine learning
Accurate balance assessment is important in healthcare for identifying and managing conditions affecting stability and coordination. It plays a key role in preventing falls, understanding movement disorders, and designing appropriate therapeutic interventions across various age groups and medical conditions. However, traditional balance assessment methods often suffer from subjectivity, lack of comprehensive balance assessments and remote assessment capabilities, and reliance on specialized equipment and expert analysis. In response to these challenges, our study introduces an innovative approach for estimating scores on the Modified Clinical Test of Sensory Interaction on Balance (m-CTSIB). Utilizing wearable sensors and advanced machine learning algorithms, we offer an objective, accessible, and efficient method for balance assessment. We collected comprehensive movement data from 34 participants under four different sensory conditions using an array of inertial measurement unit (IMU) sensors coupled with a specialized system to evaluate ground truth m-CTSIB balance scores for our analysis. This data was then preprocessed, and an extensive array of features was extracted for analysis. To estimate the m-CTSIB scores, we applied Multiple Linear Regression (MLR), Support Vector Regression (SVR), and XGBOOST algorithms. Our subject-wise Leave-One-Out and 5-Fold cross-validation analysis demonstrated high accuracy and a strong correlation with ground truth balance scores, validating the effectiveness and reliability of our approach. Key insights were gained regarding the significance of specific movements, feature selection, and sensor placement in balance estimation. Notably, the XGBOOST model, utilizing the lumbar sensor data, achieved outstanding results in both methods, with Leave-One-Out cross-validation showing a correlation of 0.96 and a Mean Absolute Error (MAE) of 0.23 and 5-fold cross-validation showing comparable results with a correlation of 0.92 and an MAE of 0.23, confirming the model’s consistent performance. This finding underlines the potential of our method to revolutionize balance assessment practices, particularly in settings where traditional methods are impractical or inaccessible.
- 19 April 2024
- Published by Frontiers Media SA in Frontiers in Digital Health
- Vol. 6, 1366176
Open AccessObjective estimation of m-CTSIB balance test scores using wearable sensors and machine learning
Accurate balance assessment is important in healthcare for identifying and managing conditions affecting stability and coordination. It plays a key role in preventing falls, understanding movement disorders, and designing appropriate therapeutic interventions across various age groups and medical conditions. However, traditional balance assessment methods often suffer from subjectivity, lack of comprehensive balance assessments and remote assessment capabilities, and reliance on specialized equipment and expert analysis. In response to these challenges, our study introduces an innovative approach for estimating scores on the Modified Clinical Test of Sensory Interaction on Balance (m-CTSIB). Utilizing wearable sensors and advanced machine learning algorithms, we offer an objective, accessible, and efficient method for balance assessment. We collected comprehensive movement data from 34 participants under four different sensory conditions using an array of inertial measurement unit (IMU) sensors coupled with a specialized system to evaluate ground truth m-CTSIB balance scores for our analysis. This data was then preprocessed, and an extensive array of features was extracted for analysis. To estimate the m-CTSIB scores, we applied Multiple Linear Regression (MLR), Support Vector Regression (SVR), and XGBOOST algorithms. Our subject-wise Leave-One-Out and 5-Fold cross-validation analysis demonstrated high accuracy and a strong correlation with ground truth balance scores, validating the effectiveness and reliability of our approach. Key insights were gained regarding the significance of specific movements, feature selection, and sensor placement in balance estimation. Notably, the XGBOOST model, utilizing the lumbar sensor data, achieved outstanding results in both methods, with Leave-One-Out cross-validation showing a correlation of 0.96 and a Mean Absolute Error (MAE) of 0.23 and 5-fold cross-validation showing comparable results with a correlation of 0.92 and an MAE of 0.23, confirming the model’s consistent performance. This finding underlines the potential of our method to revolutionize balance assessment practices, particularly in settings where traditional methods are impractical or inaccessible.