Shi-Jie Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shi-Jie Liu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Changxi Wang
Organ Transplant Center, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou 510080, China
1 shared publication - Ke Ma
Lab of Functional and Biomedical Nanomaterials, College of Materials Science and Engineering, Qingdao University of Science and Technology (QUST), Qingdao, 266042, PR China
1 shared publication - Ke Wang
Department of Artificial Intelligence, Chengdu Jincheng College, Chengdu, Sichuan, China
1 shared publication - Kezheng Chen
College of Materials Science and Engineering, Qingdao University of Science & Technology, Qingdao, Shandong 266061, China
1 shared publication Long-Shan Liu
Organ Transplant Center, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, 510020, PR China
1 shared publication- Qingling Du
School of Architecture and Engineering, Huanghuai University, Zhumadian 463000, China
1 shared publication
Latest Publications
- Open Access
- 4 September 2025
- Published by MDPI AG in Computation
- Vol. 13 (9) , 215
Time–Frequency Domain Analysis of the Ground Vibration of an Elevated Railway and Study on the Elliptic Polarization Dispersion Characteristics of Rayleigh Waves
Elevated railways are a crucial component of railway lines, characterized by their widespread distribution, simple structure, and low cost, while actively promoting local economic development. However, they also cause significant ground vibrations when trains pass. Similarly, considerable vibration levels are transmitted to the subgrade and surrounding structures when trains operate on viaducts within the Loess Plateau region. However, research on mitigating these vibration effects remains relatively scarce. This study focused on the impacts of such vibrations on surrounding buildings and stratum structures and evaluated the effectiveness of a vibration isolation trench in mitigating these effects. Time frequency domain analysis of ground vibrations during train passage revealed that the characteristic frequency of the train-induced pulse excitation in the track structure had a pronounced peak in the spectrum curve. The introduction of a vibration isolation trench effectively blocked the propagation of vibration waves in the soil, reduced soil vibration, and significantly lowered the peak value in the spectrum. Numerical simulations were employed to analyze the elliptical polarization dispersion characteristics of surface wave propagation with the vibration isolation trench in place, confirming the effective damping performance of the trench. These findings could offer a valuable reference for high-speed railway vibration isolation and significantly advance the application of surface wave theory in high-speed railway technology.
- 4 September 2025
- Published by MDPI AG in Computation
- Vol. 13 (9) , 215
Open AccessTime–Frequency Domain Analysis of the Ground Vibration of an Elevated Railway and Study on the Elliptic Polarization Dispersion Characteristics of Rayleigh Waves
Elevated railways are a crucial component of railway lines, characterized by their widespread distribution, simple structure, and low cost, while actively promoting local economic development. However, they also cause significant ground vibrations when trains pass. Similarly, considerable vibration levels are transmitted to the subgrade and surrounding structures when trains operate on viaducts within the Loess Plateau region. However, research on mitigating these vibration effects remains relatively scarce. This study focused on the impacts of such vibrations on surrounding buildings and stratum structures and evaluated the effectiveness of a vibration isolation trench in mitigating these effects. Time frequency domain analysis of ground vibrations during train passage revealed that the characteristic frequency of the train-induced pulse excitation in the track structure had a pronounced peak in the spectrum curve. The introduction of a vibration isolation trench effectively blocked the propagation of vibration waves in the soil, reduced soil vibration, and significantly lowered the peak value in the spectrum. Numerical simulations were employed to analyze the elliptical polarization dispersion characteristics of surface wave propagation with the vibration isolation trench in place, confirming the effective damping performance of the trench. These findings could offer a valuable reference for high-speed railway vibration isolation and significantly advance the application of surface wave theory in high-speed railway technology.
- 13 July 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 215, 114568
Point-of-care non-invasive enzyme-cleavable nanosensors for acute transplant rejection detection
- 13 July 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 215, 114568
Point-of-care non-invasive enzyme-cleavable nanosensors for acute transplant rejection detection