Yunxia Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yunxia Huang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Baihua Zhao
Department of Ultrasound Diagnosis, The Second Xiangya Hospital, Central South University, Changsha, China
2 shared publications - Lieming Wen
Department of Ultrasound Diagnosis, The Second Xiangya Hospital, Central South University, Changsha, China
2 shared publications - Shan Zhou
Health Management Center, The Second Xiangya Hospital, Central South University, Changsha, China
2 shared publications - Yaqian Fu
Health Management Center, The Second Xiangya Hospital, Central South University, Changsha, China
2 shared publications - Jieyu Liu
Department of Ultrasound Diagnosis, The Second Xiangya Hospital, Central South University, Changsha, China
1 shared publication - Kun Zhang
Department of Ultrasound Medicine, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China
1 shared publication
Latest Publications
- Open Access
- 6 April 2026
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 45 (3) , 241-251
Construction of a nomogram model for predicting benignity and malignancy in adnexal masses
Construction of a nomogram model for predicting benignity and malignancy in adnexal masses
- 6 April 2026
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 45 (3) , 241-251
Open AccessConstruction of a nomogram model for predicting benignity and malignancy in adnexal masses
Construction of a nomogram model for predicting benignity and malignancy in adnexal masses
- Top Cited PapersOpen Access
- 8 August 2025
- Published by Galenos Yayinevi in Balkan Medical Journal
- Vol. 42 (5) , 419-428
A Deep Learning-Based Automatic Recognition Model for Polycystic Ovary Ultrasound Images
Polycystic ovary syndrome (PCOS) has a significant impact on endocrine metabolism, reproductive function, and mental health in women of reproductive age. Ultrasound remains an essential diagnostic tool for PCOS, particularly in individuals presenting with oligomenorrhea or ovulatory dysfunction accompanied by polycystic ovaries, as well as hyperandrogenism associated with polycystic ovaries. However, the accuracy of ultrasound in identifying polycystic ovarian morphology remains variable. To develop a deep learning model capable of rapidly and accurately identifying PCOS using ovarian ultrasound images. Prospective diagnostic accuracy study. This prospective study included data from 1,751 women with suspected PCOS who presented at two affiliated hospitals at Central South University, with clinical and ultrasound information collected and archived. Patients from center 1 were randomly divided into a training set and an internal validation set in a 7:3 ratio, while patients from center 2 served as the external validation set. Using the YOLOv11 deep learning framework, an automated recognition model for ovarian ultrasound images in PCOS cases was constructed, and its diagnostic performance was evaluated. Ultrasound images from 933 patients (781 from center 1 and 152 from center 2) were analyzed. The mean average precision of the YOLOv11 model in detecting the target ovary was 95.7%, 97.6%, and 97.8% for the training, internal validation, and external validation sets, respectively. For diagnostic classification, the model achieved an F1 score of 95.0% in the training set and 96.9% in both validation sets. The area under the curve values were 0.953, 0.973, and 0.967 for the training, internal validation, and external validation sets respectively. The model also demonstrated significantly faster evaluation of a single ovary compared to clinicians (doctor, 5.0 seconds; model, 0.1 seconds; p < 0.01). The YOLOv11-based automatic recognition model for PCOS ovarian ultrasound images exhibits strong target detection and diagnostic performance. This approach can streamline the follicle counting process in conventional ultrasound and enhance the efficiency and generalizability of ultrasound-based PCOS assessment.
- 8 August 2025
- Published by Galenos Yayinevi in Balkan Medical Journal
- Vol. 42 (5) , 419-428
Top Cited PapersOpen AccessA Deep Learning-Based Automatic Recognition Model for Polycystic Ovary Ultrasound Images
Polycystic ovary syndrome (PCOS) has a significant impact on endocrine metabolism, reproductive function, and mental health in women of reproductive age. Ultrasound remains an essential diagnostic tool for PCOS, particularly in individuals presenting with oligomenorrhea or ovulatory dysfunction accompanied by polycystic ovaries, as well as hyperandrogenism associated with polycystic ovaries. However, the accuracy of ultrasound in identifying polycystic ovarian morphology remains variable. To develop a deep learning model capable of rapidly and accurately identifying PCOS using ovarian ultrasound images. Prospective diagnostic accuracy study. This prospective study included data from 1,751 women with suspected PCOS who presented at two affiliated hospitals at Central South University, with clinical and ultrasound information collected and archived. Patients from center 1 were randomly divided into a training set and an internal validation set in a 7:3 ratio, while patients from center 2 served as the external validation set. Using the YOLOv11 deep learning framework, an automated recognition model for ovarian ultrasound images in PCOS cases was constructed, and its diagnostic performance was evaluated. Ultrasound images from 933 patients (781 from center 1 and 152 from center 2) were analyzed. The mean average precision of the YOLOv11 model in detecting the target ovary was 95.7%, 97.6%, and 97.8% for the training, internal validation, and external validation sets, respectively. For diagnostic classification, the model achieved an F1 score of 95.0% in the training set and 96.9% in both validation sets. The area under the curve values were 0.953, 0.973, and 0.967 for the training, internal validation, and external validation sets respectively. The model also demonstrated significantly faster evaluation of a single ovary compared to clinicians (doctor, 5.0 seconds; model, 0.1 seconds; p < 0.01). The YOLOv11-based automatic recognition model for PCOS ovarian ultrasound images exhibits strong target detection and diagnostic performance. This approach can streamline the follicle counting process in conventional ultrasound and enhance the efficiency and generalizability of ultrasound-based PCOS assessment.