Han Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Han Liu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Da Liang
Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, China
2 shared publications- Jianfeng Xu
State Key Laboratory of Intelligent Manufacturing Equipment and Technology, School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
2 shared publications Jiayang Zeng
Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, China
2 shared publications- Qiyu Peng
Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, China
2 shared publications - Wenjing Zhu
Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, China
2 shared publications - Xin Yu
School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, China
2 shared publications
Latest Publications
- 4 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (4) , 574-581
DOI Self-Calibration Method Based on Intrinsic Radiation for Positron Emission Tomography
Depth-of-interaction (DOI) decoding can reduce localization errors in the Line-of-response (LOR), thereby improving positron emission tomography (PET) image quality, especially in high-resolution PET, long-axial PET, and small-aperture PET systems. Current PET detectors are capable of achieving high-resolution DOI decoding, but most methods rely on collimation calibration for each detector. Calibrating all detectors is labor-intensive and complicates subsequent system maintenance. We aim to achieve DOI collimation for PET detectors based on the intrinsic radiation of 176Lu, which allows us to omit the complex step of calibrating DOI for all detectors. This approach allows DOI calibration to be performed automatically during each system operation, simplifying system maintenance. The pixelated LYSO detector in this study consists of LYSO pixels with dimensions of 2 × 2 × 20 mm3. The detector is arranged in an 8×10 array configuration. We obtained the relationship between intrinsic radiation and DOI through Monte Carlo simulations, and the relationship between the MPPC signal ratio (the relative proportion of light detected by different MPPCs from the same crystal, which changes with DOI) and intrinsic radiation through experiments. This allowed us to establish a conversion function between DOI and the MPPC signal ratio. We verified the DOI resolution through collimation testing and demonstrated the improvement in image quality of the DOI self-calibration based on intrinsic radiation method using the Derenzo phantom experiment. We validated the DOI resolution of our method through mechanical collimation experiments at depths of 4 mm, 10 mm, and 16 mm, achieving an average DOI resolution full width at half maximum (FWHM) of 5.2 mm and a Mean Absolute Error (MAE) of 3.6 mm. The images reconstructed with DOI correction obtained through self-collimation demonstrated significantly improved signal-to-noise ratio and spatial resolution compared to images without DOI correction. Specifically, the spatial resolution at an offset of 45 mm improved from 3.0 mm to 2.1 mm. The DOI self-calibration method based on intrinsic radiation provides a practical and efficient solution for calibrating PET detectors without the need to add complex hardware. It should be noted that this method is only applicable to PET systems with detectors employing LSO or LYSO, and therefore this method is based on spontaneous emission of 176Lu. This method has the potential to improve the image quality of PET systems and can be readily integrated into existing detector designs.
- 4 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (4) , 574-581
DOI Self-Calibration Method Based on Intrinsic Radiation for Positron Emission Tomography
Depth-of-interaction (DOI) decoding can reduce localization errors in the Line-of-response (LOR), thereby improving positron emission tomography (PET) image quality, especially in high-resolution PET, long-axial PET, and small-aperture PET systems. Current PET detectors are capable of achieving high-resolution DOI decoding, but most methods rely on collimation calibration for each detector. Calibrating all detectors is labor-intensive and complicates subsequent system maintenance. We aim to achieve DOI collimation for PET detectors based on the intrinsic radiation of 176Lu, which allows us to omit the complex step of calibrating DOI for all detectors. This approach allows DOI calibration to be performed automatically during each system operation, simplifying system maintenance. The pixelated LYSO detector in this study consists of LYSO pixels with dimensions of 2 × 2 × 20 mm3. The detector is arranged in an 8×10 array configuration. We obtained the relationship between intrinsic radiation and DOI through Monte Carlo simulations, and the relationship between the MPPC signal ratio (the relative proportion of light detected by different MPPCs from the same crystal, which changes with DOI) and intrinsic radiation through experiments. This allowed us to establish a conversion function between DOI and the MPPC signal ratio. We verified the DOI resolution through collimation testing and demonstrated the improvement in image quality of the DOI self-calibration based on intrinsic radiation method using the Derenzo phantom experiment. We validated the DOI resolution of our method through mechanical collimation experiments at depths of 4 mm, 10 mm, and 16 mm, achieving an average DOI resolution full width at half maximum (FWHM) of 5.2 mm and a Mean Absolute Error (MAE) of 3.6 mm. The images reconstructed with DOI correction obtained through self-collimation demonstrated significantly improved signal-to-noise ratio and spatial resolution compared to images without DOI correction. Specifically, the spatial resolution at an offset of 45 mm improved from 3.0 mm to 2.1 mm. The DOI self-calibration method based on intrinsic radiation provides a practical and efficient solution for calibrating PET detectors without the need to add complex hardware. It should be noted that this method is only applicable to PET systems with detectors employing LSO or LYSO, and therefore this method is based on spontaneous emission of 176Lu. This method has the potential to improve the image quality of PET systems and can be readily integrated into existing detector designs.
- 4 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (8) , 1118-1126
Development and Performance Evaluation of a Benchtop Small-Animal PET/MRI Scanner
This study aims to develop a compact, low-cost, and high-performance benchtop small-animal PET/MRI scanner that achieves functional and anatomical image fusion. The system is designed to address challenges in cost reduction, spatial resolution, sensitivity, image quality, and quantitative accuracy. The PET/MRI system was developed with a parallel configuration, integrating a custom-designed PET scanner and a 0.5-T permanent magnet MRI system. Quantitative assessments included spatial resolution, sensitivity, image quality, and quantitative accuracy, as well as signal-to-noise ratio (SNR), geometric distortion (GD), and image uniformity for MRI. The spatial resolution at the axial center is 1.31 mm (axial), 1.26 mm (radial), and 1.22 mm (tangential), with a center sensitivity of 8.05% under a wide energy window. Image quality tests using an IQ phantom demonstrated a uniformity of 10.08 standard deviation, recovery coefficients (RC) ranging from 0.23 to 0.96, and spill-over ratios (SOR) of 0.08 and 0.18 in air and water regions, respectively. The MRI system achieved an SNR of 14.16 in phantom tests, a geometric distortion of less than 1%, and image uniformity of 90.13%. Fusion imaging of PET and MRI demonstrated high registration accuracy in both phantom and mouse studies, with complementary functional and anatomical information. The proposed PET/MRI system achieves high spatial resolution, sensitivity, image quality, and quantitative accuracy while maintaining a simple, low-cost design. The parallel configuration facilitates precise PET/MRI image fusion and allows for efficient multi-animal imaging. The results highlight the potential of this system for preclinical research and its feasibility for future in-vehicle imaging applications. Further optimization of the MRI system and data transmission methods will enhance its performance in high-activity studies and broaden its application scope, with potential applications in preclinical research and invehicle imaging.
- 4 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (8) , 1118-1126
Development and Performance Evaluation of a Benchtop Small-Animal PET/MRI Scanner
This study aims to develop a compact, low-cost, and high-performance benchtop small-animal PET/MRI scanner that achieves functional and anatomical image fusion. The system is designed to address challenges in cost reduction, spatial resolution, sensitivity, image quality, and quantitative accuracy. The PET/MRI system was developed with a parallel configuration, integrating a custom-designed PET scanner and a 0.5-T permanent magnet MRI system. Quantitative assessments included spatial resolution, sensitivity, image quality, and quantitative accuracy, as well as signal-to-noise ratio (SNR), geometric distortion (GD), and image uniformity for MRI. The spatial resolution at the axial center is 1.31 mm (axial), 1.26 mm (radial), and 1.22 mm (tangential), with a center sensitivity of 8.05% under a wide energy window. Image quality tests using an IQ phantom demonstrated a uniformity of 10.08 standard deviation, recovery coefficients (RC) ranging from 0.23 to 0.96, and spill-over ratios (SOR) of 0.08 and 0.18 in air and water regions, respectively. The MRI system achieved an SNR of 14.16 in phantom tests, a geometric distortion of less than 1%, and image uniformity of 90.13%. Fusion imaging of PET and MRI demonstrated high registration accuracy in both phantom and mouse studies, with complementary functional and anatomical information. The proposed PET/MRI system achieves high spatial resolution, sensitivity, image quality, and quantitative accuracy while maintaining a simple, low-cost design. The parallel configuration facilitates precise PET/MRI image fusion and allows for efficient multi-animal imaging. The results highlight the potential of this system for preclinical research and its feasibility for future in-vehicle imaging applications. Further optimization of the MRI system and data transmission methods will enhance its performance in high-activity studies and broaden its application scope, with potential applications in preclinical research and invehicle imaging.