Chien-Yi Liao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chien-Yi Liao has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Dan Nguyen
Medical Artificial Intelligence and Automation Laboratory Department of Radiation Oncology University of Texas Southwestern Medical Center Dallas Texas USA
2 shared publications - David Jonathan Sher
Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX
2 shared publications - Mu-Han Lin
Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
2 shared publications - Steve Jiang
University of Texas Southwestern Medical Center
2 shared publications - Chul Ahn
Department of Population and Data Sciences, University of Texas Southwestern Medical Center, Dallas, Texas
1 shared publication - Daniel X. Yang
Medical Artificial Intelligence and Automation (MAIA) Laboratory, University of Texas Southwestern Medical Center, Dallas, TX
1 shared publication
Latest Publications
- 1 April 2026
- Published by American Society of Clinical Oncology (ASCO) in JCO Clinical Cancer Informatics
- Vol. 10 (2) , e2500150
Performance of an Artificial Intelligence Foundation Model for Prostate Radiotherapy Segmentation
PURPOSE: Radiation therapy is a major treatment modality for localized prostate cancer, and accurate target segmentation is a critical aspect of radiation delivery that can directly affect patient outcomes. We evaluated the performance of an artificial intelligence (AI) foundation model in target segmentation tasks for prostate radiotherapy planning. METHODS: AI segmentation using Segment Anything Model 2 (SAM 2) was evaluated from computed tomography images with varying levels of human intervention, ranging from intervals of every 2nd to every 10th ground truth slice provided as input. Segmentation accuracy was measured using dice similarity coefficient (DSC) and 95th percentile Hausdorff distance (HD95) for intact and postoperative prostate target delineation. RESULTS: SAM 2 achieved performance similar to and, in some cases, worse than interpolation in DSC and HD95 for both intact and postoperative prostate cancer patient cases, and the AI segmentation accuracy was significantly better in the intact preoperative patient cases where anatomic boundaries were better defined than postoperative patient cases ( P < .01† for intervals 5-10). When sparse ground truth was provided simulating lower levels of human intervention, DSC values decreased from 0.956 to 0.856 in the preoperative setting and from 0.952 to 0.751 in the postoperative setting when the interval between ground truth slices was increased from every 2nd to every 10th slice. Correspondingly, the HD95 increased from 1.817 to 4.436 in the preoperative setting and from 1.988 to 11.02 in the postoperative setting under the same conditions. CONCLUSION: Current general-purpose AI foundation models do not outperform existing methods and are likely inadequate for prostate radiotherapy segmentation. Their clinical application will require further understanding of appropriate fine-tuning and task-specific performance.
- 1 April 2026
- Published by American Society of Clinical Oncology (ASCO) in JCO Clinical Cancer Informatics
- Vol. 10 (2) , e2500150
Performance of an Artificial Intelligence Foundation Model for Prostate Radiotherapy Segmentation
PURPOSE: Radiation therapy is a major treatment modality for localized prostate cancer, and accurate target segmentation is a critical aspect of radiation delivery that can directly affect patient outcomes. We evaluated the performance of an artificial intelligence (AI) foundation model in target segmentation tasks for prostate radiotherapy planning. METHODS: AI segmentation using Segment Anything Model 2 (SAM 2) was evaluated from computed tomography images with varying levels of human intervention, ranging from intervals of every 2nd to every 10th ground truth slice provided as input. Segmentation accuracy was measured using dice similarity coefficient (DSC) and 95th percentile Hausdorff distance (HD95) for intact and postoperative prostate target delineation. RESULTS: SAM 2 achieved performance similar to and, in some cases, worse than interpolation in DSC and HD95 for both intact and postoperative prostate cancer patient cases, and the AI segmentation accuracy was significantly better in the intact preoperative patient cases where anatomic boundaries were better defined than postoperative patient cases ( P < .01† for intervals 5-10). When sparse ground truth was provided simulating lower levels of human intervention, DSC values decreased from 0.956 to 0.856 in the preoperative setting and from 0.952 to 0.751 in the postoperative setting when the interval between ground truth slices was increased from every 2nd to every 10th slice. Correspondingly, the HD95 increased from 1.817 to 4.436 in the preoperative setting and from 1.988 to 11.02 in the postoperative setting under the same conditions. CONCLUSION: Current general-purpose AI foundation models do not outperform existing methods and are likely inadequate for prostate radiotherapy segmentation. Their clinical application will require further understanding of appropriate fine-tuning and task-specific performance.
- Open Access
- 19 February 2026
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 11 (5) , 102013
Intrafractional Motion and Margin Assessment for Cone Beam Computed Tomography Guided Online Adaptive Radiation Therapy in Head and Neck Cancer
- 19 February 2026
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 11 (5) , 102013
Open AccessIntrafractional Motion and Margin Assessment for Cone Beam Computed Tomography Guided Online Adaptive Radiation Therapy in Head and Neck Cancer
- Open Access
- 5 September 2025
- Published by IOP Publishing in Machine Learning: Health
- Vol. 1 (1) , 015010
Incorporating physicians’ contouring style into auto-segmentation of clinical target volume for post-operative prostate cancer radiotherapy using a language encoder
Post-operative radiotherapy for prostate cancer requires precise contouring of the clinical target volume (CTV) to account for microscopic disease that is invisible in the image. However, the absence of the prostate gland and unclear anatomical landmarks make this process challenging. In addition, the contouring style is greatly influenced by the physician’s experience and preferences. This complicates automatic segmentation algorithms that rely on consistent data but also typically need large amounts data from many physicians to develop. This study presents a novel auto-segmentation method incorporating individual physicians’ contouring styles to enhance accuracy and reduce manual workload. We develop Text-UNet, a deep learning-based model integrating a text encoder to encode physician-specific contouring styles into a latent vector. This information is combined with CT image features to guide segmentation. A dataset of 824 patients is divided into 699 training, 49 validation, and 76 testing data. The test set includes recent cases from four physicians, while the training set represents data from seven physicians. Text-UNet achieves an average Dice score of 85.1%, outperforming the baseline UNet (82.0%) and state-of-the-art models. Incorporating physician-specific information improves segmentation consistency and reduces manual contouring effort, demonstrating its potential to enhance the auto-segmentation of post-operative radiotherapy for prostate cancer. By integrating physicians’ contouring styles, Text-UNet addresses inter-physician variability, improving CTV auto-segmentation precision. This approach personalizes radiotherapy planning according to physicians and improves treatment efficiency.
- 5 September 2025
- Published by IOP Publishing in Machine Learning: Health
- Vol. 1 (1) , 015010
Open AccessIncorporating physicians’ contouring style into auto-segmentation of clinical target volume for post-operative prostate cancer radiotherapy using a language encoder
Post-operative radiotherapy for prostate cancer requires precise contouring of the clinical target volume (CTV) to account for microscopic disease that is invisible in the image. However, the absence of the prostate gland and unclear anatomical landmarks make this process challenging. In addition, the contouring style is greatly influenced by the physician’s experience and preferences. This complicates automatic segmentation algorithms that rely on consistent data but also typically need large amounts data from many physicians to develop. This study presents a novel auto-segmentation method incorporating individual physicians’ contouring styles to enhance accuracy and reduce manual workload. We develop Text-UNet, a deep learning-based model integrating a text encoder to encode physician-specific contouring styles into a latent vector. This information is combined with CT image features to guide segmentation. A dataset of 824 patients is divided into 699 training, 49 validation, and 76 testing data. The test set includes recent cases from four physicians, while the training set represents data from seven physicians. Text-UNet achieves an average Dice score of 85.1%, outperforming the baseline UNet (82.0%) and state-of-the-art models. Incorporating physician-specific information improves segmentation consistency and reduces manual contouring effort, demonstrating its potential to enhance the auto-segmentation of post-operative radiotherapy for prostate cancer. By integrating physicians’ contouring styles, Text-UNet addresses inter-physician variability, improving CTV auto-segmentation precision. This approach personalizes radiotherapy planning according to physicians and improves treatment efficiency.
- 20 August 2025
- Published by Oxford University Press (OUP) in JNCI: Journal of the National Cancer Institute
- Vol. 117 (12) , 2488-2494
Impact of daily adaptive head and neck radiotherapy on toxicity and quality of life: results of the DARTBOARD phase II randomized trial
Background: The utility of adaptive radiotherapy (ART) for head and neck squamous cell carcinoma (HNSCC) remains poorly defined. Daily ART (DART) promises both anatomic adaptation and planning target volume (PTV) reduction. In this prospective trial using cone-beam computed tomography-based ART, patients with HNSCC undergoing definitive radiotherapy (RT) or chemoradiotherapy (CRT) were randomly assigned to DART with reduced PTV margins or no ART with standard margins (image-guided RT [IGRT]). Methods: Eligibility criteria included a diagnosis of oropharynx, larynx, or hypopharynx HNSCC receiving definitive radiotherapy. All individuals received involved nodal radiotherapy per previous institutional study. The PTV margins were 1 mm (2 mm craniocaudal) vs 5 mm in the DART and IGRT arms, respectively. The primary endpoint was patient-reported xerostomia at 1 year, assessed with the Xerostomia Questionnaire (XQ). Results: Fifty patients were enrolled (26 IGRT, 24 DART) between March 2022 and June 2023. The cohort consisted of 38 oropharynx and 12 larynx/hypopharynx patients. The mean ipsilateral parotid gland, ipsilateral and contralateral submandibular gland doses were significantly lower with DART. There was significantly less acute dermatitis in the DART arm (Grade 0/1/2 0%/69%/31% vs 17%/75%/8% DART, P = .01) but no significant difference in any patient-reported outcome at 1 year. The adjusted difference in XQ score at 1 year was 10.0 (95% CI = −4.7 to 24.7, P = .58). Conclusion: Online DART for HNSCC is oncologically sound and improved acute toxicity profiles, but it did not reduce patient-reported xerostomia, the primary endpoint. Additional evidence is needed to understand the potential benefits and limitations of this paradigm, including its cost-effectiveness. Trial registration: clinicaltrials.gov identifier, NCT04883281
- 20 August 2025
- Published by Oxford University Press (OUP) in JNCI: Journal of the National Cancer Institute
- Vol. 117 (12) , 2488-2494
Impact of daily adaptive head and neck radiotherapy on toxicity and quality of life: results of the DARTBOARD phase II randomized trial
Background: The utility of adaptive radiotherapy (ART) for head and neck squamous cell carcinoma (HNSCC) remains poorly defined. Daily ART (DART) promises both anatomic adaptation and planning target volume (PTV) reduction. In this prospective trial using cone-beam computed tomography-based ART, patients with HNSCC undergoing definitive radiotherapy (RT) or chemoradiotherapy (CRT) were randomly assigned to DART with reduced PTV margins or no ART with standard margins (image-guided RT [IGRT]). Methods: Eligibility criteria included a diagnosis of oropharynx, larynx, or hypopharynx HNSCC receiving definitive radiotherapy. All individuals received involved nodal radiotherapy per previous institutional study. The PTV margins were 1 mm (2 mm craniocaudal) vs 5 mm in the DART and IGRT arms, respectively. The primary endpoint was patient-reported xerostomia at 1 year, assessed with the Xerostomia Questionnaire (XQ). Results: Fifty patients were enrolled (26 IGRT, 24 DART) between March 2022 and June 2023. The cohort consisted of 38 oropharynx and 12 larynx/hypopharynx patients. The mean ipsilateral parotid gland, ipsilateral and contralateral submandibular gland doses were significantly lower with DART. There was significantly less acute dermatitis in the DART arm (Grade 0/1/2 0%/69%/31% vs 17%/75%/8% DART, P = .01) but no significant difference in any patient-reported outcome at 1 year. The adjusted difference in XQ score at 1 year was 10.0 (95% CI = −4.7 to 24.7, P = .58). Conclusion: Online DART for HNSCC is oncologically sound and improved acute toxicity profiles, but it did not reduce patient-reported xerostomia, the primary endpoint. Additional evidence is needed to understand the potential benefits and limitations of this paradigm, including its cost-effectiveness. Trial registration: clinicaltrials.gov identifier, NCT04883281