Hélène Delanoë-Ayari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hélène Delanoë-Ayari has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Abbas Mgharbel
Laboratoire Matériaux et Phénomènes Quantiques, Centre National de la Recherche Scientifique, Unité Mixte de Recherche 5586, Université de Lyon, Université Lyon 1, 43 Boulevard du 11 novembre 1918, F-69622 Villeurbanne Cedex, France
2 shared publications- Athanasius F. M. Marée
Computational and Systems Biology, John Innes Centre, Norwich NR4 7UH, UK
1 shared publication Benjamin Audren
Laboratoire Matériaux et Phénomènes Quantiques, Centre National de la Recherche Scientifique, Unité Mixte de Recherche 5586, Université de Lyon, Université Lyon 1, 43 Boulevard du 11 novembre 1918, F-69622 Villeurbanne Cedex, France
1 shared publication- Boudewijn van der Sanden
INSERM (France)
1 shared publication François Graner
Laboratoire de Spectrométrie Physique, Unité Mixte de Recherche 5588, Université Grenoble I and Centre National de la Recherche Scientifique, 140 Avenue de la Physique, F-38402 Martin d'Hères Cedex, France
1 shared publication- Jean-Claude Vial
Université Joseph Fourier, Grenoble, France
1 shared publication
Latest Publications
- 13 October 2009
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 106 (41) , 17271-17275
The role of fluctuations and stress on the effective viscosity of cell aggregates
Cell aggregates are a tool for in vitro studies of morphogenesis, cancer invasion, and tissue engineering. They respond to mechanical forces as a complex rather than simple liquid. To change an aggregate's shape, cells have to overcome energy barriers. If cell shape fluctuations are active enough, the aggregate spontaneously relaxes stresses (“fluctuation-induced flow”). If not, changing the aggregate's shape requires a sufficiently large applied stress (“stress-induced flow”). To capture this distinction, we develop a mechanical model of aggregates based on their cellular structure. At stress lower than a characteristic stress τ*, the aggregate as a whole flows with an apparent viscosity η*, and at higher stress it is a shear-thinning fluid. An increasing cell–cell tension results in a higher η* (and thus a slower stress relaxation time t c ). Our constitutive equation fits experiments of aggregate shape relaxation after compression or decompression in which irreversibility can be measured; we find t c of the order of 5 h for F9 cell lines. Predictions also match numerical simulations of cell geometry and fluctuations. We discuss the deviations from liquid behavior, the possible overestimation of surface tension in parallel-plate compression measurements, and the role of measurement duration.
- 13 October 2009
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 106 (41) , 17271-17275
The role of fluctuations and stress on the effective viscosity of cell aggregates
Cell aggregates are a tool for in vitro studies of morphogenesis, cancer invasion, and tissue engineering. They respond to mechanical forces as a complex rather than simple liquid. To change an aggregate's shape, cells have to overcome energy barriers. If cell shape fluctuations are active enough, the aggregate spontaneously relaxes stresses (“fluctuation-induced flow”). If not, changing the aggregate's shape requires a sufficiently large applied stress (“stress-induced flow”). To capture this distinction, we develop a mechanical model of aggregates based on their cellular structure. At stress lower than a characteristic stress τ*, the aggregate as a whole flows with an apparent viscosity η*, and at higher stress it is a shear-thinning fluid. An increasing cell–cell tension results in a higher η* (and thus a slower stress relaxation time t c ). Our constitutive equation fits experiments of aggregate shape relaxation after compression or decompression in which irreversibility can be measured; we find t c of the order of 5 h for F9 cell lines. Predictions also match numerical simulations of cell geometry and fluctuations. We discuss the deviations from liquid behavior, the possible overestimation of surface tension in parallel-plate compression measurements, and the role of measurement duration.
- Open Access
Measuring accurately liquid and tissue surface tension with a compression plate tensiometer
Apparent tissue surface tension allows the quantification of cell-cell cohesion and was reported to be a powerful indicator for the cellular rearrangements that take place during embryonic development or for cancer progression. The measurement is realized with a parallel compression plate tensiometer using the capillary laws. Although it was introduced more than a decade ago, it is based on various geometrical or physical approximations. Surprisingly, these approximations have never been tested. Using a novel tensiometer, we compare the two currently used methods to measure tissue surface tension and propose a third one, based on a local polynomial fit (LPF) of the profile of compressed droplets or cell aggregates. We show the importance of measuring the contact angle between the plate and the drop/aggregate to obtain real accurate measurement of surface tension when applying existing methods. We can suspect that many reported values of surface tension are greatly affected because of not handling this parameter properly. We show then the benefit of using the newly introduced LPF method, which is not dependent on this parameter. These findings are confirmed by generating numerically compressed droplet profiles and testing the robustness and the sensitivity to errors of the different methods.
Open AccessMeasuring accurately liquid and tissue surface tension with a compression plate tensiometer
Apparent tissue surface tension allows the quantification of cell-cell cohesion and was reported to be a powerful indicator for the cellular rearrangements that take place during embryonic development or for cancer progression. The measurement is realized with a parallel compression plate tensiometer using the capillary laws. Although it was introduced more than a decade ago, it is based on various geometrical or physical approximations. Surprisingly, these approximations have never been tested. Using a novel tensiometer, we compare the two currently used methods to measure tissue surface tension and propose a third one, based on a local polynomial fit (LPF) of the profile of compressed droplets or cell aggregates. We show the importance of measuring the contact angle between the plate and the drop/aggregate to obtain real accurate measurement of surface tension when applying existing methods. We can suspect that many reported values of surface tension are greatly affected because of not handling this parameter properly. We show then the benefit of using the newly introduced LPF method, which is not dependent on this parameter. These findings are confirmed by generating numerically compressed droplet profiles and testing the robustness and the sensitivity to errors of the different methods.