Dae-Young Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Dae-Young Kim has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Dae-Hyeok Kim
Inha University College of Medicine
1 shared publication - Ji-Hun Jang
Division of Cardiology, Department of Internal Medicine, Inha University College of Medicine, Incheon, South Korea
1 shared publication - Sang-Chul Lee
Inha University
1 shared publication - Sangwon Lee
Department of Electrical and Computer Engineering, Inha University, Incheon, South Korea
1 shared publication - Sung-Hee Shin
Division of Cardiology, Department of Internal Medicine, Inha University College of Medicine, Incheon, South Korea
1 shared publication - Wonik Choi
Department of Electrical and Computer Engineering, Inha University, Incheon, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 1 October 2024
- Published by BMJ in Open Heart
- Vol. 11 (2) , e002924
Use of artificial intelligence-powered ECG to differentiate between cardiac and pulmonary pathologies in patients with acute dyspnoea in the emergency department
Background Acute dyspnoea is common in acute care settings. However, identifying the origin of dyspnoea in the emergency department (ED) is often challenging. We aimed to investigate whether our artificial intelligence (AI)-powered ECG analysis reliably distinguishes between the causes of dyspnoea and evaluate its potential as a clinical triage tool for comparing conventional heart failure diagnostic processes using natriuretic peptides. Methods A retrospective analysis was conducted using an AI-based ECG algorithm on patients ≥18 years old presenting with dyspnoea at the ED from February 2006 to September 2023. Patients were categorised into cardiac or pulmonary origin groups based on initial admission. The performance of an AI-ECG using a transformer neural network algorithm was assessed to analyse standard 12-lead ECGs for accuracy, sensitivity, specificity and area under the receiver operating characteristic curve (AUC). Additionally, we compared the diagnostic efficacy of AI-ECG models with N-terminal probrain natriuretic peptide (NT-proBNP) levels to identify cardiac origins. Results Among the 3105 patients included in the study, 1197 had cardiac-origin dyspnoea. The AI-ECG model demonstrated an AUC of 0.938 and 88.1% accuracy for cardiac-origin dyspnoea. The sensitivity, specificity and positive and negative predictive values were 93.0%, 79.5%, 89.0% and 86.4%, respectively. The F1 score was 0.828. AI-ECG demonstrated superior diagnostic performance in identifying cardiac-origin dyspnoea compared with NT-proBNP. True cardiac origin was confirmed in 96 patients in a sensitivity analysis of 129 patients with a high probability of cardiac origin initially misdiagnosed as pulmonary origin predicted by AI-ECG. Conclusions AI-ECG demonstrated superior diagnostic accuracy over NT-proBNP and showed promise as a clinical triage tool. It is a potentially valuable tool for identifying the origin of dyspnoea in emergency settings and supporting decision-making.
- 1 October 2024
- Published by BMJ in Open Heart
- Vol. 11 (2) , e002924
Open AccessUse of artificial intelligence-powered ECG to differentiate between cardiac and pulmonary pathologies in patients with acute dyspnoea in the emergency department
Background Acute dyspnoea is common in acute care settings. However, identifying the origin of dyspnoea in the emergency department (ED) is often challenging. We aimed to investigate whether our artificial intelligence (AI)-powered ECG analysis reliably distinguishes between the causes of dyspnoea and evaluate its potential as a clinical triage tool for comparing conventional heart failure diagnostic processes using natriuretic peptides. Methods A retrospective analysis was conducted using an AI-based ECG algorithm on patients ≥18 years old presenting with dyspnoea at the ED from February 2006 to September 2023. Patients were categorised into cardiac or pulmonary origin groups based on initial admission. The performance of an AI-ECG using a transformer neural network algorithm was assessed to analyse standard 12-lead ECGs for accuracy, sensitivity, specificity and area under the receiver operating characteristic curve (AUC). Additionally, we compared the diagnostic efficacy of AI-ECG models with N-terminal probrain natriuretic peptide (NT-proBNP) levels to identify cardiac origins. Results Among the 3105 patients included in the study, 1197 had cardiac-origin dyspnoea. The AI-ECG model demonstrated an AUC of 0.938 and 88.1% accuracy for cardiac-origin dyspnoea. The sensitivity, specificity and positive and negative predictive values were 93.0%, 79.5%, 89.0% and 86.4%, respectively. The F1 score was 0.828. AI-ECG demonstrated superior diagnostic performance in identifying cardiac-origin dyspnoea compared with NT-proBNP. True cardiac origin was confirmed in 96 patients in a sensitivity analysis of 129 patients with a high probability of cardiac origin initially misdiagnosed as pulmonary origin predicted by AI-ECG. Conclusions AI-ECG demonstrated superior diagnostic accuracy over NT-proBNP and showed promise as a clinical triage tool. It is a potentially valuable tool for identifying the origin of dyspnoea in emergency settings and supporting decision-making.