A Data-Driven PCA–OCSVM Framework for Intelligent Monitoring and Anomaly Detection of Grid-Connected PV Inverters Under Multitask Operation
This study proposes an unsupervised anomaly detection method to identify the performance degradation in grid-connected photovoltaic (PV) inverters under multitask operation. Principal Component Analysis (PCA) and One-Class Support Vector Machine (OCSVM) were integrated to build a detection model using routine operational data. The key features include DC input, AC output, AC/DC ratio, and AC power variation, which are reduced to two principal components for anomaly boundary construction. The inverters were flagged as degraded if the AC/DC ratio was <0.96, the power fluctuation exceeded 20%, or the data fell outside the OCSVM-defined boundary. Compared with the Isolation Forest, the proposed method showed higher sensitivity. When applied to a 120 MW PV plant in Taiwan with 1292 inverters, including 55 PV-STATCOM units at night, the framework detected degradation in 5.4% of them. These results support their use in intelligent monitoring and predictive maintenance. In addition, through early fault detection and maintenance prioritization, the proposed framework contributes to enhancing reliability, reducing maintenance costs, and promoting the sustainable operation of utility-scale photovoltaic power plants.
- 21 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (23) , 12394
Open AccessA Data-Driven PCA–OCSVM Framework for Intelligent Monitoring and Anomaly Detection of Grid-Connected PV Inverters Under Multitask Operation
This study proposes an unsupervised anomaly detection method to identify the performance degradation in grid-connected photovoltaic (PV) inverters under multitask operation. Principal Component Analysis (PCA) and One-Class Support Vector Machine (OCSVM) were integrated to build a detection model using routine operational data. The key features include DC input, AC output, AC/DC ratio, and AC power variation, which are reduced to two principal components for anomaly boundary construction. The inverters were flagged as degraded if the AC/DC ratio was <0.96, the power fluctuation exceeded 20%, or the data fell outside the OCSVM-defined boundary. Compared with the Isolation Forest, the proposed method showed higher sensitivity. When applied to a 120 MW PV plant in Taiwan with 1292 inverters, including 55 PV-STATCOM units at night, the framework detected degradation in 5.4% of them. These results support their use in intelligent monitoring and predictive maintenance. In addition, through early fault detection and maintenance prioritization, the proposed framework contributes to enhancing reliability, reducing maintenance costs, and promoting the sustainable operation of utility-scale photovoltaic power plants.
- Open Access
- 28 October 2025
- Published by MDPI AG in Preprints.org
A Data-Driven PCA–OCSVM Framework for Intelligent Monitoring and Anomaly Detection of Grid-Connected PV Inverters under Multitask Operation
This study proposes an unsupervised anomaly detection method to identify the performance degradation in grid-connected photovoltaic (PV) inverters under multitask operation. Principal Component Analysis (PCA) and One-Class Support Vector Machine (OCSVM) were integrated to build a detection model using routine operational data. The key features include DC input, AC output, AC/DC ratio, and AC power variation, which are reduced to two principal components for anomaly boundary construction. The inverters were flagged as degraded if the AC/DC ratio was <0.96, the power fluctuation exceeded 20%, or the data fell outside the OCSVM-defined boundary. Compared with the Isolation Forest, the proposed method showed higher sensitivity. When applied to a 120 MW PV plant in Taiwan with 1,292 inverters, including 55 PV-STATCOM units at night, the framework detected degradation in 5.4% of them. These results support their use in intelligent monitoring and predictive maintenance.
- 28 October 2025
- Published by MDPI AG in Preprints.org
Open AccessA Data-Driven PCA–OCSVM Framework for Intelligent Monitoring and Anomaly Detection of Grid-Connected PV Inverters under Multitask Operation
This study proposes an unsupervised anomaly detection method to identify the performance degradation in grid-connected photovoltaic (PV) inverters under multitask operation. Principal Component Analysis (PCA) and One-Class Support Vector Machine (OCSVM) were integrated to build a detection model using routine operational data. The key features include DC input, AC output, AC/DC ratio, and AC power variation, which are reduced to two principal components for anomaly boundary construction. The inverters were flagged as degraded if the AC/DC ratio was <0.96, the power fluctuation exceeded 20%, or the data fell outside the OCSVM-defined boundary. Compared with the Isolation Forest, the proposed method showed higher sensitivity. When applied to a 120 MW PV plant in Taiwan with 1,292 inverters, including 55 PV-STATCOM units at night, the framework detected degradation in 5.4% of them. These results support their use in intelligent monitoring and predictive maintenance.
- Open Access
- 21 October 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (20) , 11282
A Hybrid GA–Digital Twin Strategy for Real-Time Nighttime Reactive Power Compensation in Utility-Scale PV Plants
This study proposes a hybrid method that combines a Genetic Algorithm (GA) with Digital Twin (DT) technology to address nighttime reactive power backfeed in large-scale photovoltaic (PV) power plants. First, the GA is employed to optimize the location and number of multitask inverters to minimize line losses and eliminate the reactive power backfeed. Subsequently, the DT continuously monitored the grid conditions and performed rolling dispatch to mitigate the residual reactive power caused by nighttime voltage fluctuations. Simulation results show that GA-based optimization reduces line losses from 0.346 to 0.2818 kW (18.6% reduction) and helps alleviate inverter thermal stress. When integrated with DTs, the method further improves voltage stability and demonstrates a strong adaptive control capability. The proposed GA–DT strategy can also be regarded as a potential AIoT application in PV plants, with the potential to reduce operational and maintenance costs and enhance the system reliability in the future.
- 21 October 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (20) , 11282
Open AccessA Hybrid GA–Digital Twin Strategy for Real-Time Nighttime Reactive Power Compensation in Utility-Scale PV Plants
This study proposes a hybrid method that combines a Genetic Algorithm (GA) with Digital Twin (DT) technology to address nighttime reactive power backfeed in large-scale photovoltaic (PV) power plants. First, the GA is employed to optimize the location and number of multitask inverters to minimize line losses and eliminate the reactive power backfeed. Subsequently, the DT continuously monitored the grid conditions and performed rolling dispatch to mitigate the residual reactive power caused by nighttime voltage fluctuations. Simulation results show that GA-based optimization reduces line losses from 0.346 to 0.2818 kW (18.6% reduction) and helps alleviate inverter thermal stress. When integrated with DTs, the method further improves voltage stability and demonstrates a strong adaptive control capability. The proposed GA–DT strategy can also be regarded as a potential AIoT application in PV plants, with the potential to reduce operational and maintenance costs and enhance the system reliability in the future.
- Open Access
- 6 October 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (19) , 10748
Nighttime Reactive Power Optimization for Large-Scale PV Plants: Minimizing Compensation Equipment Investment
The increasing integration of photovoltaic (PV) power systems poses challenges for nighttime voltage regulation because long high-voltage (HV) and ultra-high-voltage (UHV) underground cables generate capacitive reactive power that elevates the grid voltage. Conventional compensators based on passive inductors and capacitors are bulky, costly, and inflexible, rendering them unsuitable for substation use. This study proposes an optimization-based strategy that leverages the existing inverter infrastructure of PV plants to provide nighttime reactive power compensation without additional hardware. A genetic algorithm (GA) determines the optimal number and spatial deployment of inverters to minimize line losses. Field validation at a 120 MW PV plant with 1292 inverters shows that the strategy reduces reverse reactive power from 0.84 MVAr to 0.00214 MVAr and line losses from 1.8235 kW to 0.386 kW using only 55 inverters, achieving near-zero additional capital expenditure (CAPEX). This method enhances the voltage stability and system efficiency while reducing the investment and maintenance costs.
- 6 October 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (19) , 10748
Open AccessNighttime Reactive Power Optimization for Large-Scale PV Plants: Minimizing Compensation Equipment Investment
The increasing integration of photovoltaic (PV) power systems poses challenges for nighttime voltage regulation because long high-voltage (HV) and ultra-high-voltage (UHV) underground cables generate capacitive reactive power that elevates the grid voltage. Conventional compensators based on passive inductors and capacitors are bulky, costly, and inflexible, rendering them unsuitable for substation use. This study proposes an optimization-based strategy that leverages the existing inverter infrastructure of PV plants to provide nighttime reactive power compensation without additional hardware. A genetic algorithm (GA) determines the optimal number and spatial deployment of inverters to minimize line losses. Field validation at a 120 MW PV plant with 1292 inverters shows that the strategy reduces reverse reactive power from 0.84 MVAr to 0.00214 MVAr and line losses from 1.8235 kW to 0.386 kW using only 55 inverters, achieving near-zero additional capital expenditure (CAPEX). This method enhances the voltage stability and system efficiency while reducing the investment and maintenance costs.
- Open Access
- 12 September 2025
- Published by MDPI AG in Preprints.org
A Hybrid GA–Digital Twin Strategy for Real-Time Nighttime Reactive Power Compensation in Utility-Scale PV Plants
This paper proposes a hybrid strategy that integrates a Genetic Algorithm (GA) with Digital Twin (DT) technology to address the issue of nighttime reactive power backfeed in large-scale photovoltaic (PV) power plants. First, a GA is employed to optimize the location and number of multitask inverters to minimize line losses and eliminate the reactive power backfeed. Subsequently, the DT continuously monitors the grid conditions and performs a rolling dispatch of the inverter units to respond to the residual reactive power caused by the nighttime voltage fluctuations. The experimental results show that GA-based optimization reduces the line losses from 0.346 kW to 0.2818 kW, a reduction of approximately 18.6%, and helps to prevent thermal damage to the inverters. When combined with DT technology, the strategy further enhances voltage stability and demonstrates strong adaptive control capabilities. The proposed method effectively reduces the operation and maintenance costs of PV plants and shows a promising potential for practical deployment.
- 12 September 2025
- Published by MDPI AG in Preprints.org
Open AccessA Hybrid GA–Digital Twin Strategy for Real-Time Nighttime Reactive Power Compensation in Utility-Scale PV Plants
This paper proposes a hybrid strategy that integrates a Genetic Algorithm (GA) with Digital Twin (DT) technology to address the issue of nighttime reactive power backfeed in large-scale photovoltaic (PV) power plants. First, a GA is employed to optimize the location and number of multitask inverters to minimize line losses and eliminate the reactive power backfeed. Subsequently, the DT continuously monitors the grid conditions and performs a rolling dispatch of the inverter units to respond to the residual reactive power caused by the nighttime voltage fluctuations. The experimental results show that GA-based optimization reduces the line losses from 0.346 kW to 0.2818 kW, a reduction of approximately 18.6%, and helps to prevent thermal damage to the inverters. When combined with DT technology, the strategy further enhances voltage stability and demonstrates strong adaptive control capabilities. The proposed method effectively reduces the operation and maintenance costs of PV plants and shows a promising potential for practical deployment.
- Open Access
- 9 September 2025
- Published by MDPI AG in Preprints.org
Nighttime Reactive Power Optimization for Large-Scale PV Plants: Minimizing Compensation Equipment Investment
The increasing integration of photovoltaic (PV) power systems poses challenges for nighttime voltage regulation, as long high-voltage (HV) and ultra-high-voltage (UHV) underground cables generate capacitive reactive power that elevates grid voltage. Conventional compensators, based on passive inductors and capacitors, are bulky, costly, and inflexible, making them unsuitable for existing substations. This study proposes an optimization-based strategy that leverages the existing inverter infrastructure of PV plants to provide nighttime reactive power compensation without additional hardware. A genetic algorithm (GA) determines the optimal number and spatial deployment of inverters to minimize line losses. Field validation at a 120 MW PV plant with 1,292 inverters shows that the strategy reduces reverse reactive power from 0.84 MVAr to 0.00214 MVAr and line losses from 1.8235 kW to 0.386 kW using only 55 inverters, achieving near-zero additional capital expenditure (CAPEX). The method enhances voltage stability and system efficiency while reducing investment and maintenance costs.
- 9 September 2025
- Published by MDPI AG in Preprints.org
Open AccessNighttime Reactive Power Optimization for Large-Scale PV Plants: Minimizing Compensation Equipment Investment
The increasing integration of photovoltaic (PV) power systems poses challenges for nighttime voltage regulation, as long high-voltage (HV) and ultra-high-voltage (UHV) underground cables generate capacitive reactive power that elevates grid voltage. Conventional compensators, based on passive inductors and capacitors, are bulky, costly, and inflexible, making them unsuitable for existing substations. This study proposes an optimization-based strategy that leverages the existing inverter infrastructure of PV plants to provide nighttime reactive power compensation without additional hardware. A genetic algorithm (GA) determines the optimal number and spatial deployment of inverters to minimize line losses. Field validation at a 120 MW PV plant with 1,292 inverters shows that the strategy reduces reverse reactive power from 0.84 MVAr to 0.00214 MVAr and line losses from 1.8235 kW to 0.386 kW using only 55 inverters, achieving near-zero additional capital expenditure (CAPEX). The method enhances voltage stability and system efficiency while reducing investment and maintenance costs.