Joanderson Felipe Soares Silva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Joanderson Felipe Soares Silva has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Rafael Pereira
State University of Southwest Bahia (UESB)
4 shared publications - Alinne Alves Oliveira
State University of Southwest Bahia (UESB), Jequié, Brazil
3 shared publications - Mikhail Santos Cerqueira
State University of Southwest Bahia (UESB)
3 shared publications - Claudineia Matos de Araújo Gesteira
Universidade Estadual do Sudoeste da Bahia
2 shared publications - Cláudia Thais Pereira Pinto
Integrative Physiology Research Center, Department of Biological Sciences, Universidade Estadual do Sudoeste da Bahia (UESB), Jequie 45210-506, Bahia, Brazil
2 shared publications - Luciano Magno de Almeida Faria
Universidade Estadual do Sudoeste da Bahia
2 shared publications
Latest Publications
- Open Access
- 4 November 2026
- Published by Springer Nature in European Journal of Applied Physiology
- p. 1-10
Decoupling the neurovascular axis: autonomic and hemodynamic determinants of intracranial pulse wave morphology via principal component analysis
Purpose: This study investigated the integrated relationship between systemic hemodynamics, autonomic modulation, and non-invasive intracranial pulse wave morphology (P2/P1 ratio) across na adult age range under basal seated resting conditions. Methods: Two hundred ninety-nine healthy volunteers (137 males, 162 females; mean age 48.74 ± 24 years) were evaluated. Blood pressure, heart rate, symbolic heart rate variability (0 V, sympathetic; 2UV, parasympathetic), and P2/P1 ratio via scalp extensometry were recorded. Principal Component Analysis (PCA) with Varimax rotation was applied to eight normalized variables (Age, HR, SBP, DBP, PP, 0 V, 2UV, and P2/P1). Results: Four components explained 85.81% of variance. PC1 (34.04%) comprised age (loading 0.802), PP (0.824), SBP (0.883), and P2/P1 (0.647), representing an age-pulsatile axis. PC2 (25.46%) captured autonomic dynamics, dominated by 0 V and 2UV. PC3 (13.93%) was dominated by DBP, whereas PC4 (12.38%) showed a P2/P1 loading (0.560). Spearman analysis showed associations of age with P2/P1 (ρ = 0.623, p < 0.05), PP (ρ = 0.479, p < 0.05), and SBP (ρ = 0.472, p < 0.05). P2 > P1 morphology was more frequent among older participants and higher PP. Conclusion: Under basal seated resting conditions, P2/P1 was associated with age and pulsatile hemodynamics, particularly PP, while autonomic modulation represented a partially distinct component. The P2/P1 variance in PC4 suggests additional factors not captured by the systemic variables examined. These findings support this non-invasive framework as an exploratory approach for studying cerebrovascular and craniospinal dynamics across adulthood, but do not establish causality or equivalence with invasive measurements.
- 4 November 2026
- Published by Springer Nature in European Journal of Applied Physiology
- p. 1-10
Open AccessDecoupling the neurovascular axis: autonomic and hemodynamic determinants of intracranial pulse wave morphology via principal component analysis
Purpose: This study investigated the integrated relationship between systemic hemodynamics, autonomic modulation, and non-invasive intracranial pulse wave morphology (P2/P1 ratio) across na adult age range under basal seated resting conditions. Methods: Two hundred ninety-nine healthy volunteers (137 males, 162 females; mean age 48.74 ± 24 years) were evaluated. Blood pressure, heart rate, symbolic heart rate variability (0 V, sympathetic; 2UV, parasympathetic), and P2/P1 ratio via scalp extensometry were recorded. Principal Component Analysis (PCA) with Varimax rotation was applied to eight normalized variables (Age, HR, SBP, DBP, PP, 0 V, 2UV, and P2/P1). Results: Four components explained 85.81% of variance. PC1 (34.04%) comprised age (loading 0.802), PP (0.824), SBP (0.883), and P2/P1 (0.647), representing an age-pulsatile axis. PC2 (25.46%) captured autonomic dynamics, dominated by 0 V and 2UV. PC3 (13.93%) was dominated by DBP, whereas PC4 (12.38%) showed a P2/P1 loading (0.560). Spearman analysis showed associations of age with P2/P1 (ρ = 0.623, p < 0.05), PP (ρ = 0.479, p < 0.05), and SBP (ρ = 0.472, p < 0.05). P2 > P1 morphology was more frequent among older participants and higher PP. Conclusion: Under basal seated resting conditions, P2/P1 was associated with age and pulsatile hemodynamics, particularly PP, while autonomic modulation represented a partially distinct component. The P2/P1 variance in PC4 suggests additional factors not captured by the systemic variables examined. These findings support this non-invasive framework as an exploratory approach for studying cerebrovascular and craniospinal dynamics across adulthood, but do not establish causality or equivalence with invasive measurements.
- 29 September 2026
- Published by IOP Publishing in Physiological Measurement
- Vol. 47 (9) , 095009
Measurement properties and operational feasibility of an automated arterial occlusion pressure assessment system for blood flow restriction exercise
Objective. To evaluate the validity, reliability, agreement, and operational feasibility of an automated arterial occlusion pressure (AOP) assessment system compared with a manual Doppler-based assessment. Approach. Forty healthy adults (20 men and 20 women) completed upper- and lower-limb (LL) AOP assessments using automated and MDA methods in a randomized and counterbalanced design. Concurrent validity, agreement, intraday and interday reliability, operational feasibility, perceptual responses, and procedure-related symptoms were evaluated. Exploratory analyses examined whether sex modified the difference between automated and MDA-derived AOP measurements. Main results. MDA demonstrated good-to-excellent reliability (ICC = 0.84–0.98; CV = 1.38%–3.25%). The automated system demonstrated moderate-to-good intraday reliability (ICC = 0.74–0.85) but poor LL interday reliability (ICC = 0.36). Compared with MDA, automated AOP showed systematic bias and wide limits of agreement. No evidence of a sex-related difference in the between-method discrepancy was observed for either upper- or LL AOP. Although automated assessment reduced testing time by 81.9%–86.7%, frequent upper-limb (UL) measurement failures reduced the automated measurement success rate to approximately 57%, substantially increasing adjusted assessment time and limiting operational feasibility, while discomfort and affective responses were more favorable than with MDA. Significance. The automated AOP system improved assessment efficiency and participant experience but demonstrated less favorable reliability estimates, limited agreement, and frequent upper-limb measurement failures. Consequently, automated and MDA should not be considered interchangeable for individualized AOP prescription.
- 29 September 2026
- Published by IOP Publishing in Physiological Measurement
- Vol. 47 (9) , 095009
Measurement properties and operational feasibility of an automated arterial occlusion pressure assessment system for blood flow restriction exercise
Objective. To evaluate the validity, reliability, agreement, and operational feasibility of an automated arterial occlusion pressure (AOP) assessment system compared with a manual Doppler-based assessment. Approach. Forty healthy adults (20 men and 20 women) completed upper- and lower-limb (LL) AOP assessments using automated and MDA methods in a randomized and counterbalanced design. Concurrent validity, agreement, intraday and interday reliability, operational feasibility, perceptual responses, and procedure-related symptoms were evaluated. Exploratory analyses examined whether sex modified the difference between automated and MDA-derived AOP measurements. Main results. MDA demonstrated good-to-excellent reliability (ICC = 0.84–0.98; CV = 1.38%–3.25%). The automated system demonstrated moderate-to-good intraday reliability (ICC = 0.74–0.85) but poor LL interday reliability (ICC = 0.36). Compared with MDA, automated AOP showed systematic bias and wide limits of agreement. No evidence of a sex-related difference in the between-method discrepancy was observed for either upper- or LL AOP. Although automated assessment reduced testing time by 81.9%–86.7%, frequent upper-limb (UL) measurement failures reduced the automated measurement success rate to approximately 57%, substantially increasing adjusted assessment time and limiting operational feasibility, while discomfort and affective responses were more favorable than with MDA. Significance. The automated AOP system improved assessment efficiency and participant experience but demonstrated less favorable reliability estimates, limited agreement, and frequent upper-limb measurement failures. Consequently, automated and MDA should not be considered interchangeable for individualized AOP prescription.
- Open Access
- 10 April 2026
- Published by MDPI AG in Geriatrics
- Vol. 11 (2) , 44
Comparison of Physical Performance and Muscle Thickness Between Older Women with High and Low Fall Risk: A Bayesian Approach
Objective: The present study aimed to compare muscle thickness and physical performance in different functional tests predicting falls between older adults with low and high fall risk. Methods: Seventy-one community-dwelling older women (74.5 ± 8.5 years old) volunteered for this study. The Berg Balance Scale (BBS) was used to stratify the sample as low and high risk for fall (BBS cutoff = ≥ 50 points). The performance in the Timed Up and Go Test (TUGT), 5-repetition sit-to-stand test (5xSST), 3 m walk test (3mWT), and 3 m backward walk test (3mBWT) was assessed. The elbow flexor and knee extensor muscle thickness were obtained by ultrasound (USD). A linear mixed model analysis was used to determine between-group differences in functional mobility and muscle thickness, and Bayesian analysis was applied to check the probability to replicate the same results (i.e., the magnitude of the evidence). Results: The low-fall-risk group exhibited significantly better performance only in 3mWT (mean difference = 0.84 s [95% CI: 0.40 to 1.29 s]; p = 0.001) and 3mBWT (mean difference = 1.54 s [95% CI: 0.21 to 2.85 s]; p = 0.024). The Bayes Factor (BF) for performance on the 3mWT and 3mBWT shows that the low-fall-risk group has a probability of 98.7% (BF10 = 77.3) and 99.7% (BF10 = 368), respectively, of performing better than the high-fall-risk group. Conclusions: Based on inferential and Bayesian analysis, the performance in 3mWT and that in 3mBWT were classified as very strong to excellent instruments, respectively, for differentiating older women with high fall risk.
- 10 April 2026
- Published by MDPI AG in Geriatrics
- Vol. 11 (2) , 44
Open AccessComparison of Physical Performance and Muscle Thickness Between Older Women with High and Low Fall Risk: A Bayesian Approach
Objective: The present study aimed to compare muscle thickness and physical performance in different functional tests predicting falls between older adults with low and high fall risk. Methods: Seventy-one community-dwelling older women (74.5 ± 8.5 years old) volunteered for this study. The Berg Balance Scale (BBS) was used to stratify the sample as low and high risk for fall (BBS cutoff = ≥ 50 points). The performance in the Timed Up and Go Test (TUGT), 5-repetition sit-to-stand test (5xSST), 3 m walk test (3mWT), and 3 m backward walk test (3mBWT) was assessed. The elbow flexor and knee extensor muscle thickness were obtained by ultrasound (USD). A linear mixed model analysis was used to determine between-group differences in functional mobility and muscle thickness, and Bayesian analysis was applied to check the probability to replicate the same results (i.e., the magnitude of the evidence). Results: The low-fall-risk group exhibited significantly better performance only in 3mWT (mean difference = 0.84 s [95% CI: 0.40 to 1.29 s]; p = 0.001) and 3mBWT (mean difference = 1.54 s [95% CI: 0.21 to 2.85 s]; p = 0.024). The Bayes Factor (BF) for performance on the 3mWT and 3mBWT shows that the low-fall-risk group has a probability of 98.7% (BF10 = 77.3) and 99.7% (BF10 = 368), respectively, of performing better than the high-fall-risk group. Conclusions: Based on inferential and Bayesian analysis, the performance in 3mWT and that in 3mBWT were classified as very strong to excellent instruments, respectively, for differentiating older women with high fall risk.
- Open Access
- 10 September 2025
- Published by MDPI AG in Preprints.org
Comparison of Physical Performance and Muscle Thickness between Older Women with High and Low Fall Risk: A Bayesian Approach
Objective: The present study aimed to compare performance in different functional tests predicting falls between older adults with low and high fall risk. Methods: Seventy-one community-dwelling older women volunteered for this study. Berg Balance Scale (BBS) was used to stratify the sample as: low and high risk for fall (BBS cutoff = ≥ 50 points). The performance in Time Up and Go Test (TUGT), 5-repetition sit-to-stand test (5xSST), 3-meter walk test (3mWT), 3-meter backward walk test (3mBWT). The elbow flexor and knee extensor muscle thickness was obtained by ultrasound (USD). A linear mixed model analysis was used to determine between-group differences in functional mobility and muscle thickness, and Bayesian analysis was applied to check the probability to replicate the same results (i.e., the magnitude of the evidence). Results: The low fall risk group exhibited significantly better performance only in 3mWT (mean difference = 0.84 s [95% CI: 0.40 to 1.29 seconds]; p = 0.001) and 3mBWT (mean difference = 1.54 seconds [95% CI: 0.21 to 2.85 seconds]; p = 0.024). The Bayes Factor (BF) for performance on the 3mWT and 3mBWT shows that the low fall risk group has a probability of 98.7% (BF10 = 77.3) and 99.7% (BF10 = 368), respectively, to perform better than the high fall risk group. Conclusion: Based on inferential and Bayesian analysis, the performance in 3mWT and 3mBWT was classified as very strong to excellent instruments, respectively, to differentiate older women with high fall risk.
- 10 September 2025
- Published by MDPI AG in Preprints.org
Open AccessComparison of Physical Performance and Muscle Thickness between Older Women with High and Low Fall Risk: A Bayesian Approach
Objective: The present study aimed to compare performance in different functional tests predicting falls between older adults with low and high fall risk. Methods: Seventy-one community-dwelling older women volunteered for this study. Berg Balance Scale (BBS) was used to stratify the sample as: low and high risk for fall (BBS cutoff = ≥ 50 points). The performance in Time Up and Go Test (TUGT), 5-repetition sit-to-stand test (5xSST), 3-meter walk test (3mWT), 3-meter backward walk test (3mBWT). The elbow flexor and knee extensor muscle thickness was obtained by ultrasound (USD). A linear mixed model analysis was used to determine between-group differences in functional mobility and muscle thickness, and Bayesian analysis was applied to check the probability to replicate the same results (i.e., the magnitude of the evidence). Results: The low fall risk group exhibited significantly better performance only in 3mWT (mean difference = 0.84 s [95% CI: 0.40 to 1.29 seconds]; p = 0.001) and 3mBWT (mean difference = 1.54 seconds [95% CI: 0.21 to 2.85 seconds]; p = 0.024). The Bayes Factor (BF) for performance on the 3mWT and 3mBWT shows that the low fall risk group has a probability of 98.7% (BF10 = 77.3) and 99.7% (BF10 = 368), respectively, to perform better than the high fall risk group. Conclusion: Based on inferential and Bayesian analysis, the performance in 3mWT and 3mBWT was classified as very strong to excellent instruments, respectively, to differentiate older women with high fall risk.