GNGuoliang Niu

Guoliang Niu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Guoliang Niu has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • High-pressure generation above 45 GPa over a 10 mm3 volume with a multi-anvil press

    by Guoliang Niu, Lianjie Man, Peiyang Mu, Junkai Li, Rémy Pierru, Amrita Chakraborti, Shuai Tang, Cheng Qian, Shengbo Cao, Shijing Zhao, et al.

    High-pressure generation in multi-anvil presses has long been limited to pressures below ∼25 GPa when millimeter-scale samples are required. In this study, we systematically optimized the experimental setup for a Kawai-cell assembly using tungsten carbide anvils with a truncation edge length (TEL) of 3 mm to extend the achievable pressure range. Our results show that, in contrast to previous studies using smaller assemblies (TEL = 1.5 and 1.0 mm), tapering the anvils solely has a negligible effect on pressure-generation capability for the large sample volumes investigated here, despite a substantial increase in anvil gap under the same load. In contrast, reducing the gasket volume significantly improves the efficiency of press-load transmission to the sample, enabling an ∼33% increase in pressure compared with conventional designs using the same type of anvil. Using the optimized gasket design together with ultrahard tungsten carbide anvils with a 1° taper (TJS01, Fujilloy; TEL = 3 mm), pressures of up to 45.8 GPa were achieved at room temperature while maintaining a truncation-confined volume >10 mm3 and an anvil gap >0.3 mm. This technical breakthrough not only enables the synthesis of functional materials with large sample volumes at pressures above 45 GPa but also opens doors to unprecedentedly high pressures for precise physical property measurements that require large sample volumes and large anvil gaps, including ultrasonic interferometry, electrical impedance, and thermal conductivity measurements in a multi-anvil press.

  • Open Access

    Screening of TiB2-based ternary composites for X-ray transparent heaters in high-pressure and high-temperature experiments

    by Yutian Zhang, Guoliang Niu, Pengfei Tan, Chuanhui Zhu, Huiyang Gou, David Walker, Man-Rong Li

    High-pressure and high-temperature (HPHT) experiments in large-volume presses (LVPs) benefit from reliable, available, and affordable heaters to achieve stable and homogeneous heating and, in some circumstances, X-ray transparency for monitoring of properties of an in situ experiment using X-ray diffraction and contrast imaging techniques. We have developed heaters meeting the above requirements, and we screen the ternary system TiB2–SiC–hexagonal (h)BN (denoted as TSB) to enable manufacture of X-ray transparent heaters for HPHT runs. Heaters fabricated using optimized TSB-631 (60%TiB2–30%SiC–10%hBN by weight) have been tested in modified truncated assemblies, showing excellent performance up to 22 GPa and 2395 K in HPHT runs. TSB-631 has good ceramic machinability, outstanding reproducibility, high stability, and negligible temperature gradient for runs at 3–7 GPa with cell assemblies with truncated edge lengths of 8–12 mm. The fabricated heaters not only show excellent performance in HPHT runs, but also demonstrate high X-ray transparency over a wide X-ray wavelength region, indicating potential applications for in situ X-ray diffraction/imaging under HPHT conditions in LVPs and other high-pressure apparatus.


  • Open Access

    MASTer: A high-performance stable temperature controller for high-pressure multi-anvil presses

    by Guoliang Niu, Shengbo Cao, Bingmin Yan, Huiyang Gou, Tomoo Katsura, Ho-Kwang Mao

    Maintaining stable high temperatures under pressure remains a challenge in high-pressure, high-temperature experiments using multi-anvil presses (MAPs). Temperature fluctuations exceeding 10 °C at high pressures are common and particularly problematic with LaCrO3 heaters, which can experience significant power fluctuations and even failure due to substantial resistance changes—an issue conventional thyristor-controlled heating systems cannot effectively manage. To address this limitation, we have developed the Multi-Anvil Stable Temperature controller (MASTer), a high-performance heating system optimized for MAP experiments. MASTer enables precise, high-speed measurement of heating parameters and power output control, incorporating a gentle regulation strategy to enhance stability. It ensures consistent heating across various heater types, including LaCrO3, with power fluctuations limited to ±0.1 W and temperature fluctuations to within ±2 °C in most cases. The design, operating principles, user interface, functionality, and performance of the heating system are discussed in detail.